pressure transmitter,temperature Transmitter,flow meter-ST-YK CLD

ABB FCB450 Coriolis mass flowmeter

ABB FCB450 Coriolis mass flowmeter

Manufacturer: ABB

Size: 100*100*100cm

Detail Specification:  Coriolis mass flowmeter

Comment:Carton

Shipping Weight: 50Kg

Estimated Lead Time: 12Weeks

Payment:T/T

HS CODE: 9026201090

product details

ABB FCB450 Coriolis mass flowmeter

 

ABB FCB450 Coriolis Mass Flowmeter: When You Need That 0.1% Accuracy

If you are reading this, you probably already know the ABB FCB450 Coriolis mass flowmeter is the big brother of the popular FCB430. But here at ST-YUKE CO., LIMITED, we get asked all the time: “Is it really worth stepping up to the 450?”

The short answer? If your process involves high-value product transfers, batching, or custody transfer applications where every decimal point matters, absolutely yes. Let’s break down exactly what makes this meter tick and why it might be the perfect fit for your skid.

What Makes the FCB450 Different?

At first glance, the FCB450 looks like its sibling. Same compact design, same ability to be stuffed into tight spaces with no upstream or downstream pipework required -1. But under the hood, it is a different beast.

The biggest headline is accuracy. While the FCB430 is a workhorse at 0.2% or 0.25%, the FCB450 steps into “reference standard” territory -1. We are talking about laboratory-grade performance bolted right into your industrial pipeline.

Technical Specifications That Actually Mean Something

Here is the data you came for. No fluff, just the numbers that matter when you are speccing out a meter.

Flow Ranges (Pick Your Pipe Size)

Like the 430, the 450 covers the full spectrum from small-diameter additive lines to main process lines -1-5:

DN 15 (1/2 in.): 0 to 8,000 kg/h (17,637 lb/h)

DN 25 (1 in.): 0 to 35,000 kg/h (77,162 lb/h)

DN 50 (2 in.): 0 to 90,000 kg/h (198,416 lb/h)

DN 80 (3 in.): 0 to 250,000 kg/h (551,156 lb/h)

DN 100 (4 in.): 0 to 520,000 kg/h (1,146,404 lb/h)

DN 150 (6 in.): 0 to 860,000 kg/h (1,895,975 lb/h)

 

The Accuracy You Pay For

This is where the FCB450 leaves the 430 in the dust -1-8:

Mass Flow (Liquids): 0.15% or 0.1% of rate. Yes, you read that right—0.1%.

Volume Flow: 0.15% of rate.

Density: This is the killer feature. Depending on your calibration, you can get 2 g/l, 1 g/l, or even 0.4 g/l accuracy.

 

Why does density matter? Because if you are measuring concentration (like Brix, Baume, or API gravity), that 0.4 g/l resolution lets you replace a lab sample with a real-time reading.

Temperature Range

The FCB450 handles hotter processes than the 430 -1-5. The standard range runs from -50 °C to 205 °C (-58 °F to 400 °F) . So if you are dealing with hot oils, polymers, or high-temp hygienic applications, you are covered.

Wetted Materials

You have choices depending on your fluid compatibility -1:

Stainless Steel: 1.4404 / 1.4435 (316L)

Hastelloy C

The Software Advantage: DensiMass and FillMass

Here is something you do not get on the base model. The FCB450 comes loaded with two specific software packages that change the game -1-8.

DensiMass is for direct concentration measurement. If you are mixing ingredients or need to verify product quality inline, this calculates concentration straight from the density reading. No secondary analyzers needed.

FillMass is built for filling applications. Think about filling drums, IBC totes, or tank trucks. This software optimizes the batch control, handling things like overrun compensation and fast cut-off. It turns the flowmeter into a batch controller.

Built Tough for the Real World

Ambient Conditions

This meter is designed to survive. It is rated for 70 °C (158 °F) ambient temperature and handles high vibration environments without flinching -1-6. The electronics enclosure is IP 65/67 (NEMA 4X) , so dust and hose-downs are not an issue -2.

Modular I/O

You get 5 modular I/Os, meaning you can configure exactly what you need -1. Options include:

Analog: 4-20 mA (active/passive)

Digital: HART 7.1, MODBUS, PROFIBUS DP

Ethernet: Ethernet/IP, Modbus TCP, and even a built-in Web Server

Power Supply Options

DC: 11 to 30 V DC

AC: 110/230 V AC

Smart Features You Will Actually Use

VeriMass On-Board Verification

You do not want to pull a meter just to check if it is healthy. VeriMass runs diagnostics to check for erosion, corrosion, or sensor damage -1. It gives you confidence that your 0.1% reading is still valid without sending the unit to a calibration lab.

SensorApplicationMemory

This is one of those features you do not appreciate until you need it. All the sensor data (calibration, configuration) is stored in the sensor head itself -1. If the electronics ever fail, you just swap the board. Plug it in, and it auto-configures. No laptop, no manual re-entry.

Operation Through the Glass

The display has capacitive keys that work right through the glass window -1. You can configure the meter or check readings without opening the housing. In a hazardous area or a wet environment, that is a huge safety win.

Installation Tips

Because it is a Coriolis meter, you do not need straight runs. But a few best practices help -2:

For Liquids: Mount horizontally with the electronics housing facing up to avoid trapped air, or mount vertically in an ascending line.

For Gases: Vertical mounting is best to keep the tubes free of liquid.

Keep it Full: Ensure back pressure keeps the tubes completely filled to maintain accuracy.

Why Source From ST-YUKE CO., LIMITED?

Look, the ABB FCB450 Coriolis mass flowmeter is a precision instrument. The model code can get complicated—things like FCB450.Y0.Y0.050R1.D4.A1.C.3.D1.G0.A mean something specific to your application (explosion protection, calibration type, output cards) -7.

Getting that code wrong means getting a meter that does not fit your network or your process.

At ST-YUKE CO., LIMITED, we help you navigate the options. Whether you need the base AC version for a water skid or a full cFMus Div 1 certified unit with Ethernet/IP for a refinery, we make sure the part number matches your tag plate.

Final Thoughts

The ABB FCB450 is the choice when “close enough” is not good enough. With accuracy down to 0.1% and density resolution as tight as 0.4 g/l, it pulls double duty as a flowmeter and a concentration monitor.

If you are speccing out a new line or upgrading an existing one, reach out to the team at ST-YUKE CO., LIMITED. We speak fluent ABB and we are here to help you get the right tool for the job.

 

Obtain relevant certificates and quotations for the product

Scroll to Top

Send Us a Message