pressure transmitter,temperature Transmitter,flow meter-ST-YK CLD

E&H 5BH electromagnetic flowmeter

E&H 5BH electromagnetic flowmeter

MODEL:5BH12-AG601AB041A3

Manufacturer: ENDRESS + HAUSER

Size: 100*100*100cm

Detail Specification: electromagnetic flowmeter

Comment:Carton

Shipping Weight: 50Kg

Estimated Lead Time: 12 Weeks

Payment:T/T

HS CODE:9026201090

 

product details

E&H 5BH electromagnetic flowmeter

The Complete Technical Guide to the E&H 5BH Electromagnetic Flowmeter: Precision Batch Control for Filling Applications

In the demanding fields of food & beverage, pharmaceutical, and chemical filling, precision, repeatability, and hygienic design are paramount. The E&H 5BH electromagnetic flowmeter, part of the Endress+Hauser Dosimag series, stands as the dedicated solution for volumetric flow measurement in filling and batching applications. Engineered for the fastest filling cycles and most compact installation spaces, the 5BH series delivers unparalleled accuracy and reliability for conductive liquids in hygienic environments .

As a trusted supplier, ST-YUKE CO., LIMITED offers a comprehensive range of the E&H 5BH electromagnetic flowmeter configurations. Whether you require a micro DN4 unit for precision dosing or a larger DN25 installation for main filling lines, understanding the technical nuances of this device is crucial for optimal process integration. This guide provides an in-depth look at the technical parameters, model breakdown, and ordering code for the versatile E&H 5BH series .

Key Technical Specifications of the E&H 5BH Series

The E&H 5BH electromagnetic flowmeter is engineered for bidirectional measurement of liquids with a minimum conductivity of ≥5 μS/cm. Its operation is virtually independent of pressure, density, temperature, and viscosity, making it exceptionally stable for filling applications -7-9.

ParameterSpecification
Measuring PrincipleElectromagnetic induction -1
Primary ApplicationsFood & beverage filling, pharmaceutical dosing, cosmetic manufacturing, chemical batching, system integration for OEMs -3-6
Nominal Diameter RangeDN 4 to DN 25 (1/8 to 1 inch) -7
Measuring Range0.14 to 1.66 l/s (0.035 to 0.44 gal/s) -4-7
Maximum Measurement Error±0.25% o.r. ± 1…4 m/s; ±0.5% o.r. ± 1 mm/s; ±5% o.r. (depending on model) -4-7
Medium Temperature RangeEPDM seal: -20 to +130°C (-4 to +266°F); Silicone seal: -20 to +130°C (-4 to +266°F); Viton seal: 0 to +150°C (+32 to +302°F) -4-7
Maximum Process PressurePN 16 (230 psi) -1-3-7
Minimum Conductivity≥5 μS/cm -3-6
Flow Velocity Range0.0330 to 33 ft/sec (0.0101 to 10.06 m/sec) -1
Wetted MaterialsLiner: PFA; Electrodes: 1.4435 (316L), Alloy C22 2.4602 (UNS N06022), Tantalum, Platinum -4-7
Outputs & CommunicationPulse/frequency/switch output (passive); Modbus RS485 -1-7
Enclosure RatingsIP67, stainless steel housing -4
Hygienic Certifications3-A认证, EHEDG tested, FDA compliance -3-6
Key FeatureUltra-compact design for tight installation spaces; identical process connections with Dosimass Coriolis for easy interchangeability -1-3
Additional CapabilitiesCIP/SIP cleaning capable; stainless steel housing; insensitive to pipeline vibration -3-6

Comprehensive E&H 5BH Model Variants

The versatility of the E&H 5BH electromagnetic flowmeter is reflected in its range of model numbers, which denote specific nominal diameters (DN) and application requirements. Below is a list of common variants available through ST-YUKE CO., LIMITED, covering everything from micro dosing to full-scale filling operations.

Nominal DiameterE&H 5BH Model Numbers
Micro to Small (DN4 – DN15)5BH04 (DN4), 5BH08 (DN8), 5BH12 (DN12), 5BH15 (DN15) -4
Medium (DN22 – DN26)5BH22 (DN22), 5BH26 (DN26)
Special Variants5DH15, 5SH08, 5SH12

Decoding the E&H 5BH Ordering Code: A Detailed Example

To illustrate the configurability of the E&H 5BH electromagnetic flowmeter, let us break down a specific product code: 5BH12-AG601AB041A3 -4.

Position 1-5: The Base Model

5BH12: This identifies the device as a Dosimag with a nominal diameter of DN12. This mid-range size is ideal for filling applications requiring moderate flow rates in food, beverage, and pharmaceutical production lines -4.

Position 6: Process Connection

A: Indicates the specific process connection type. For the 5BH series, “A” typically denotes a standard hygienic connection compatible with common filling system interfaces -4.

Position 7: Seal Material

G: Specifies the gasket/seal material. While options include EPDM, Silicone, and Viton, “G” may indicate a specific FDA-compliant material suitable for food contact applications -4-7.

Position 8-9: Electrode & Calibration

60: This two-digit code defines:

6: Electrode material (likely 316L stainless steel or Alloy C22)

0: Calibration type (Standard calibration) -4

Position 10: Electrode Design

1: Specifies the electrode design variant. For the 5BH series, this may indicate pin-type electrodes suitable for hygienic applications -4.

Position 11: Certification

A: Indicates the approval type. “A” typically signifies non-hazardous area certification, suitable for general food and pharmaceutical environments -4.

Position 12: Housing

B: Specifies the housing design. “B” typically denotes the compact, IP67-rated stainless steel enclosure designed for tight installation spaces -4.

Position 13: Electrical Connection

0: Defines the electrical connection type. “0” may indicate no pre-wired cable or a specific connector type.

Position 14: Power Supply

4: Specifies the power supply configuration. “4” typically indicates 24V DC operation, standard for most filling machinery -4.

Position 15: Software/Communication

1: Defines the software functionality and communication protocol. “1” may indicate basic functionality with pulse/frequency outputs -1.

Position 16: Output Configuration

A: Specifies the input/output configuration. For the 5BH series, this typically relates to the pulse output characteristics.

Position 17: Option

3: Indicates additional options. “3” may specify two pulse/frequency/status outputs up to 10kHz, passive -4.

Why Choose ST-YUKE CO., LIMITED for Your E&H 5BH?

Selecting the right configuration of an E&H 5BH electromagnetic flowmeter requires deep product knowledge and application expertise. At ST-YUKE CO., LIMITED, we specialize in helping clients navigate the complexities of the 5BH series—from the micro 5BH04 for precision dosing to the 5BH26 for higher-capacity filling lines.

Our team ensures you receive the exact device for your application, configured with the correct seals, electrodes, and communication protocols required by your filling machinery -7. We understand the critical importance of:

Repeatability: The 5BH delivers exceptional repeatability even in the shortest measurement times, ensuring consistent fill volumes -3-6

Hygienic Design: Full stainless steel construction with CIP/SIP capability and FDA-compliant materials -3-6

Space Optimization: Ultra-compact design allows multiple units to be mounted in close proximity on filling carousels -1-4

Interchangeability: Same process connections as Dosimass Coriolis meters for flexible system design -1-3

By choosing ST-YUKE CO., LIMITED, you benefit from:

Technical Expertise: Guidance on selecting the correct model and configuration for your specific filling application

Genuine Products: Assurance of authentic Endress+Hauser devices with full hygienic certifications -6-7

Global Logistics: Efficient shipping to project sites worldwide, including support for OEM and system integration projects

Application Support: Assistance with integration into existing filling lines and control systems

 

Obtain relevant certificates and quotations for the product

Scroll to Top

Send Us a Message