E&H 5H2B electromagnetic flowmeter
E&H 5H2B electromagnetic flowmeter
| MODEL:5H2B02-AAAACAAA1PAA Manufacturer: ENDRESS + HAUSER Size: 100*100*100cm Detail Specification:electromagnetic flow meter Comment:Carton Shipping Weight: 30Kg Estimated Lead Time: 12 Weeks Payment:T/T HS CODE:9026201090
|
product details
E&H 5H2B electromagnetic flowmeter
Complete Technical Guide: E&H 5H2B Proline Promag H 200 Electromagnetic Flowmeter for Hygienic and Chemical Applications
Supplier: ST-YUKE CO., LIMITED – Your Trusted Source for Process Instrumentation
In the demanding environments of chemical manufacturing, life sciences, and food & beverage industries, the need for precise, reliable, and intrinsically safe flow measurement is paramount. The E&H 5H2B electromagnetic flowmeter, part of the Endress+Hauser Proline Promag H 200 series, sets the standard with its genuine two-wire loop-powered technology . As a dedicated supplier, ST-YUKE CO., LIMITED offers the complete range of 5H2B models, providing energy-efficient solutions for hazardous areas and challenging hygienic applications.
This detailed guide covers the technical specifications, model variants, and ordering code structure for the E&H 5H2B, assisting you in selecting the ideal solution for your critical processes.
The E&H 5H2B Series: 6 Core Variants for Demanding Applications
The E&H 5H2B is engineered for applications with the highest requirements in chemical and life sciences industries . Featuring genuine loop-powered technology and an intrinsically safe design (Ex ia), it enables seamless integration into existing infrastructure while ensuring maximum operational safety in hazardous areas . ST-YUKE CO., LIMITED stocks and supplies all 6 primary size classifications:
5H2B02 (DN 2) – For ultra-low flow rates down to 0.06 dm³/min
5H2B04 (DN 4) – Precision measurement for small diameter piping
5H2B08 (DN 8) – Ideal for laboratory and pilot plant applications
5H2B15 (DN 15) – Compact solution for hygienic skid systems
5H2B22 (DN 25) – Most popular size for general chemical processing
5H2B26 (DN 25 variant) – Specialized connection configuration
Note: The Promag H 200 series succeeds the previous Promag 23H model, offering enhanced performance and Heartbeat Technology .
Detailed Ordering Code Analysis: Model 5H2B02-AAAACAAA1PAA
Understanding the Endress+Hauser product structure is essential for accurate configuration. ST-YUKE CO., LIMITED provides expert support in decoding these complex order codes. Below is a breakdown of the specific model 5H2B02-AAAACAAA1PAA:
| Position | Code Component | Description / Interpretation |
| 1-5 | 5H2B02 | Basic Type & Nominal Diameter: Promag H 200, DN 2 (designed for smallest flow quantities) . |
| 6 | A | Approval: Non-hazardous area / standard version. |
| 7 | A | Transmitter: Standard transmitter with 4-20mA HART output. |
| 8 | A | Power Supply: 24V DC loop-powered (two-wire technology) . |
| 9 | A | Outputs & Inputs: 4-20mA HART (passive) with pulse/frequency/switch output (passive) . |
| 10 | C | Display & Operation: 4-line backlit display with touch control (external operation without opening the device) . |
| 11 | A | Housing: Compact, AlSi10Mg coated . |
| 12 | A | Electrical Connection: Gland M20. |
| 13 | A | Sensor Cable Connection: Not used (compact housing). |
| 14 | 1P | Process Connection: Specific hygienic fitting (e.g., clamp or dairy fitting – exact type defined by E+H specifications). |
| 15 | A | Electrode Material: 1.4435 (316L) stainless steel . |
| 16 | A | Calibration: Standard 0.5% accuracy flow calibration . |
Interpretation based on standard E+H product structuring and available references .
Core Technical Specifications
The E&H 5H2B delivers exceptional performance through its advanced two-wire technology and Heartbeat Technology diagnostics. Below are the key technical parameters for products available from ST-YUKE CO., LIMITED:
General Information
Product Series: Proline Promag H 200
Measuring Principle: Electromagnetic induction (Faraday’s Law of Induction)
Primary Applications: Chemical, Life Sciences, Food & Beverage, Pharmaceutical
Key Feature: Genuine loop-powered two-wire technology, intrinsically safe design (Ex ia)
Performance Characteristics
Measuring Range: From 0.06 dm³/min to 300 m³/h (0.015 to 80 gal/min)
Nominal Diameter Range: DN 2 to 25 (¹⁄₁₂ to 1″)
Max. Measurement Error: Volume flow: ±0.5% o.r. ± 2 mm/s (0.08 in/s)
Measured Variables: Volume flow, mass flow
Bidirectional Measurement: Yes, independent of pressure, density, temperature, and viscosity
Operating Conditions
Medium Temperature Range: –20 to +150 °C (–4 to +302 °F)
Ambient Temperature Range: –40 to +60 °C (–40 to +140 °F)
Max. Process Pressure: PN 40, Class 150, 20K
Conductivity: Suitable for liquids with conductivity ≥ 5 µS/cm (typical for two-wire electromagnetic meters)
Materials (Wetted and External)
Liner: PFA (high chemical resistance, CIP/SIP cleanable)
Electrodes: 1.4435 (316L); Alloy C22 2.4602 (UNS N06022); Tantalum; Platinum
Process Connections: Stainless steel 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: O-ring seal (EPDM, FKM, Kalrez); Aseptic molded seal (EPDM, FKM, Silicone)
Grounding Rings: Stainless steel 1.4435 (316L); Alloy C22 2.4602; Tantalum
Sensor Housing Material: 1.4301 (304), corrosion-resistant stainless steel
Transmitter Housing Material: AlSi10Mg, coated
Communication, Integration, and Diagnostics
Digital Communication: HART, PROFIBUS PA, FOUNDATION Fieldbus
Outputs: 4-20 mA HART (passive); Pulse/frequency/switch output (passive)
Power Supply: DC 18 to 35 V (for 4-20 mA HART with/without pulse/frequency/switch output)
Heartbeat Technology: Integrated verification and diagnostics for proactive maintenance and process safety, complying with ISO 9001 for traceable verification
Display/Operation: 4-line backlit display with touch control (operation from outside without opening the device)
Approvals and Protection
Ingress Protection: IP66/67, Type 4X enclosure
Special Protection: Optional IP69 for high-pressure, high-temperature washdown
Hazardous Area Approvals: ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC, JPN, UK Ex, KC
Functional Safety: SIL compliant according to IEC 61508 / IEC 61511
Hygienic Approvals: 3-A, EHEDG tested (liner and seals FDA compliant)
Real-World Model Examples Available from ST-YUKE CO., LIMITED
To illustrate the variety of configurations available, here are some specific models within the E&H 5H2B family that our team can supply:
5H2B04-AABECDFFAS0A : A DN 4 model currently in stock, configured for standard chemical applications .
5H2B22-C3AECDBI3S0DDA : A DN 22 variant with enhanced features and specific I/O configuration .
5H2B15-C3AECDBI3S0DDA : DN 15 model suitable for pilot plant installations.
5H2B02-AABECAAA4P0A : DN 2 model for ultra-low flow measurement in laboratory settings.
5H2B04-AABECAAA4P0A : Compact DN 4 version for pharmaceutical skids .
5H2B08-AABECAAA4P0A : DN 8 configuration for hygienic applications .
5H2B15-AABECAAA4P0A : Popular DN 15 size for general purpose use .
5H2B22-AABECAAA4P0A : Widely used DN 22 model for chemical processing .
5H2B26-AABECAAA4P0A : Specialized DN 26 variant for specific connection requirements .
Key Advantages of the E&H 5H2B Two-Wire Technology
The E&H 5H2B offers unique benefits that differentiate it from traditional four-wire electromagnetic flowmeters:
1. Genuine Loop-Powered Operation
With true two-wire technology, the 5H2B is powered directly from the 4-20 mA signal loop, eliminating the need for separate power supplies and reducing installation costs . This makes it ideal for remote locations and skid-mounted systems where power availability is limited.
2. Intrinsically Safe Design (Ex ia)
The loop-powered design inherently supports intrinsic safety, allowing the 5H2B to be installed directly in hazardous areas (Zone 0/1) without complex and expensive explosion-proof enclosures .
3. Energy-Saving Flow Measurement
The reduced bore design creates no pressure loss, resulting in significant energy savings over the lifetime of the instrument .
4. Separate Connection Compartment
The dual-compartment housing allows for convenient wiring—the electronics remain sealed and protected while terminations are being made .
5. Heartbeat Technology
Built-in verification allows for on-demand diagnostics without process interruption, supporting predictive maintenance strategies and reducing unplanned downtime .
Why Partner with ST-YUKE CO., LIMITED for Your E&H 5H2B Requirements?
Selecting the right two-wire flowmeter for hazardous or hygienic applications requires in-depth product knowledge and a reliable supply chain. ST-YUKE CO., LIMITED is committed to delivering excellence in process automation:
Complete Portfolio Access: We offer all 6 major variants of the E&H 5H2B, from the ultra-compact 5H2B02 for minimal flows to the versatile 5H2B22 and specialized 5H2B26 configurations.
Configuration Expertise: Our technical team can assist in deciphering complex order codes, ensuring you receive the correct device for your specific process conditions, temperature ranges, and hazardous area requirements.
Global Sourcing Capabilities: We maintain relationships with global suppliers to source both standard configurations and hard-to-find models with specific options.
Competitive Solutions: We provide cost-effective access to advanced two-wire technology, catering to both standard requirements and specialized chemical processing needs.