E&H 5H5B electromagnetic flowmeter
E&H 5H5B electromagnetic flowmeter
| Model:5H5B04-BBDBAAAAFBABABAA1PBAA2+AA Manufacturer: ENDRESS + HAUSER Size: 100*100*100cm Detail Specification: electromagnetic flowmeter Comment:Carton Shipping Weight: 50Kg Estimated Lead Time: 12 Weeks Payment:T/T HS CODE:9026201090
|
product details
E&H 5H5B electromagnetic flowmeter
Technical Guide to the ENDRESS+HAUSER E&H 5H5B Proline Promag H 500 Remote Electromagnetic Flowmeter
In hygienic processing environments where high temperatures, aggressive cleaning agents, and limited installation space pose challenges, the remote version of the Promag H series offers the ideal solution. The ENDRESS+HAUSER E&H 5H5B electromagnetic flowmeter, part of the Proline Promag H 500 series with a 分体式 (remote) transmitter, represents the next generation of hygienic flow measurement technology. Building upon the success of the H300 platform, the H500 variant is engineered to meet the most stringent requirements of the food, beverage, and life sciences industries while offering enhanced functionality and connectivity .
By separating the sensor from the transmitter, this configuration maximizes installation flexibility and protects the electronics from harsh process conditions. As a trusted supplier, ST-YUKE CO., LIMITED is pleased to offer this detailed technical overview of the sophisticated 5H5B H500 remote flowmeter to assist engineers and procurement specialists in their selection process.
Product Overview: The E&H 5H5B H500 Remote Electromagnetic Flowmeter
The E&H 5H5B electromagnetic flowmeter combines the proven Promag H sensor technology with the advanced Proline 500 transmitter in a remote-mount format. This design is specifically tailored for applications requiring hygienic safety, high accuracy, and protection of the electronic components from washdowns or high ambient temperatures .
It features a robust PFA liner and a stainless steel sensor housing (IP69 rated), making it resistant to the aggressive cleaning agents and high temperatures associated with CIP (Clean-in-Place) and SIP (Sterilize-in-Place) processes. The remote transmitter, which can be mounted up to 300 meters away, offers up to 4 fully configurable input/output channels and user-defined I/O functionality for complete process visibility
With the integration of Heartbeat Technology, the 5H5B H500 offers continuous self-diagnostics and the ability to perform in-situ verification without interrupting the process, ensuring compliance and maximizing plant uptime .
In-Depth Model Code Breakdown: 5H5B04-BBDBAAAAFBABABAA1PBAA2+AA
The ordering structure for the ENDRESS+HAUSER 5H5B is highly modular, allowing for precise configuration to match specific application requirements. To illustrate this, ST-YUKE CO., LIMITED provides a detailed breakdown of a specific model, the 5H5B04-BBDBAAAAFBABABAA1PBAA2+AA.
Understanding this code is crucial for ensuring you receive the correct device for your remote-mount application. Here is the technical breakdown of this particular configuration:
5H5B: Product root. This designates the device as a Proline Promag H 500 electromagnetic flowmeter with a 分体式 (remote) transmitter version .
04: Nominal Diameter. This specific model is a DN 4, designed for small flow rates commonly found in lab-scale, pilot plants, or additive processes .
B: Approval. This indicates ATEX/IECEx Zone 0/1 approval for potentially explosive atmospheres .
B: Power Supply; Output; Input. “B” corresponds to a 20-28 VAC / 20-28 VDC power supply with a 4-20 mA HART current output.
D: Display; Operation. “D” signifies a 4-line, illuminated display with touch control, allowing for easy on-site configuration and data reading on the remote transmitter.
B: Housing. “B” denotes the remote transmitter housing in hygienic stainless steel, offering robustness and corrosion resistance.
A: Electrical Connection Sensor Side. This code stands for gland M20 on the sensor connection housing.
A: Electrical Connection Transmitter Side. This code stands for gland M20 on the transmitter housing.
A: Measuring Electrodes. Standard material 1.4435 (316L) stainless steel .
A: Lining. Standard PFA liner for hygienic applications .
A: Process Connection. This specific code represents a Tri-Clamp clamp connection, manufactured from 1.4404 (316L) stainless steel, which is a universal standard for hygienic connections requiring frequent dismantling for cleaning .
F: Additional Options; Sensor. PTFE cable entry thread adapter.
B: Additional Options; Sensor. With WLAN local interface for wireless configuration .
A: Test; Certificate. Standard calibration with 0.5% accuracy.
B: Additional Approval. With COC (Certificate of Conformance) to EN10204 2.1.
A: Application Package. No application package pre-configured.
B: Accessory Mounted. With test magnet.
A: Accessory Enclosed. No enclosed accessories.
A: Firmware Version. A specific firmware feature set as per firmware history.
A: Output; Input 2. No second output/input.
1: Output; Input 3. No third output/input.
P: Device Version. Hardware version of the device.
B: Extended Order Code 1. Specific additional documentation.
A: Extended Order Code 2. Specific additional documentation.
A: Extended Order Code 3. Specific additional documentation.
2: Extended Order Code 4. Specific additional documentation.
+AA: Additional Specs. Extended order code for additional services or documentation.
Complete Series Overview: Available 5H5B H500 Model Variants
The E&H 5H5B electromagnetic flowmeter series is available in a wide range of sizes to cover diverse flow rates, from small-volume additive dosing to main process lines. Below is a list of common model roots available through ST-YUKE CO., LIMITED, each representing a different nominal diameter :
5H5B02 (DN 2) – For ultra-low flow rates from 0.06 dm³/min
5H5B04 (DN 4) – For laboratory and pilot plant applications
5H5B08 (DN 8) – For small-scale additive processes
5H5B15 (DN 15) – For ingredient dosing applications
5H5B22 (DN 25) – For batching and blending operations
5H5B26 (DN 40) – For intermediate process lines
5H5B40 (DN 50) – For main product transfer lines
5H5B50 (DN 80) – For high-capacity filling operations
5H5B65 (DN 100) – For large process lines
5H5B80 (DN 125) – For main utility connections
5H5B1H (DN 150) – For maximum flow rates up to 600 m³/h
5H5B1Z (Special version) – Custom configurations
5H5B1F (Special version) – Custom configurations with specific approvals
Key Technical Specifications
For engineering and design purposes, here are the core performance parameters for the 5H5B H500 series :
| Parameter | Specification |
| Measuring Principle | Electromagnetic induction (Faraday’s Law) |
| Measured Variables | Volume flow, temperature, conductivity, mass flow, corrected volume flow, corrected conductivity |
| Nominal Diameter Range | DN 2 to 150 (¹⁄₁₂ to 6″) |
| Measurement Accuracy | Standard: ±0.5% o.r. ± 1 mm/s; Optional: ±0.2% o.r. ± 2 mm/s |
| Measuring Range | 0.06 dm³/min to 600 m³/h (0.015 to 2,650 gal/min) |
| Medium Temperature Range | –20 to +150 °C (–4 to +302 °F), suitable for hot CIP/SIP media |
| Ambient Temperature Range | –40 to +60 °C (–40 to +140 °F) |
| Max. Process Pressure | PN 40, Class 150, 20K |
| Liner Material | PFA (chemically resistant and hygienic, FDA compliant) |
| Electrode Materials | 1.4435 (316L), Alloy C22, Tantalum, Platinum |
| Sensor Housing Material | 1.4301 (304) stainless steel, corrosion resistant |
| Sensor Connection Housing | Standard: AlSi10Mg coated; Optional: 1.4301 (304) or 1.4409 (CF3M) |
| Transmitter Housing Material | AlSi10Mg coated; 1.4409 (CF3M); Polycarbonate |
| Degree of Protection | Sensor remote: IP66/67, Type 4X (standard); IP69 (optional); Transmitter: IP66/67, Type 4X |
| Cable Length | Up to 300 meters between sensor and remote transmitter |
| Display/Operation | 4-line backlit display with touch control (external operation), WLAN access |
| Outputs | Up to 4 outputs: 4-20 mA HART, 4-20 mA, Pulse/Frequency/Switch, Relay |
| Inputs | Status input, 4-20 mA input |
| Digital Communication | HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, Ethernet/IP, OPC-UA |
| Power Supply | 24 VDC; 100-230 VAC; 100-230 VAC / 24 VDC (non-hazardous area) |
| Hazardous Area Approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC |
| Hygienic Approvals | EHEDG, 3-A, FDA compliant liner and seals |
| Functional Safety | According to IEC 61508, applicable in IEC 61511 safety applications |
Advanced Features of the H500 Transmitter
The 5H5B H500 distinguishes itself from the H300 variant through several enhanced capabilities:
Multivariable Measurement
The H500 transmitter enables simultaneous measurement of volume flow, temperature, and conductivity, providing comprehensive process insights from a single device .
Enhanced Connectivity
With support for industrial Ethernet protocols including PROFINET and Ethernet/IP, the 5H5B H500 seamlessly integrates into modern Industry 4.0 architectures .
Extended I/O Capabilities
Up to 4 freely configurable inputs and outputs allow for customized process integration without the need for additional hardware.
Heartbeat Technology
Built-in verification capabilities allow for on-demand device testing without process interruption, supporting predictive maintenance strategies and regulatory compliance .
WLAN Interface
The integrated WLAN module enables wireless configuration and monitoring via mobile devices, improving accessibility in challenging installation environments .
Why Choose the Remote H500 Version for Your Hygienic Process?
The E&H 5H5B H500 stands out in applications where the sensor must be installed in tight spaces, in areas subject to high-pressure washdown (IP69), or where the process temperature exceeds the limits of the electronics. By placing the transmitter with itsbacklit display andtouch control in an accessible, operator-friendly location, you retain full functionality without compromising the sensor’s placement.
The bidirectional measuring principle is virtually independent of pressure, density, temperature, and viscosity, ensuring consistent accuracy across varying process conditions . With no moving parts and a completely crevice-free design certified by 3-A and EHEDG, the 5H5B prevents bacterial growth, ensuring product purity while eliminating maintenance requirements .
Source Your E&H 5H5B H500 from ST-YUKE CO., LIMITED
As a specialized supplier, ST-YUKE CO., LIMITED is dedicated to providing industry-leading measurement technology. Whether you require a standard 5H5B40-AAINABAAFAABLDFFAS0AA1 for a beverage application or a customized variant like the 5H5B04-BBDBAAAAFBABABAA1PBAA2+AA for a pharmaceutical process, we offer the technical expertise to help you configure the right remote flowmeter for your application -5.