The Ultimate Guide to the E&H 5W3B Electromagnetic Flowmeter: Technical Specifications for Water & Wastewater

In the demanding fields of water and wastewater management, precision, durability, and reliability are non-negotiable. The E&H 5W3B electromagnetic flowmeter, part of the Endress+Hauser Proline Promag W 300 series, stands as a global benchmark for volumetric flow measurement. Designed to master harsh conditions while delivering unparalleled accuracy, the 5W3B series is the go-to solution for industrial and municipal applications.

As a trusted supplier, ST-YUKE CO., LIMITED offers a comprehensive range of the E&H 5W3B electromagnetic flowmeter configurations. Whether you require a compact DN32 unit or a massive DN2400 installation, understanding the technical nuances of this device is crucial for optimal process integration. This guide provides an in-depth look at the technical parameters, model breakdown, and ordering code for the versatile E&H 5W3B series

Key Technical Specifications of the E&H 5W3B Series

The E&H 5W3B electromagnetic flowmeter is engineered for bidirectional measurement of conductive liquids. Its operation is virtually independent of pressure, density, temperature, and viscosity, making it exceptionally stable for water and wastewater applications

Measuring Principle: Electromagnetic induction

Primary Applications: Industrial & municipal water, wastewater, slurries, and liquids with high solids content.

Measurement Range: From 0.5 m³/h to an impressive 263,000 m³/h (depending on line size), accommodating a wide spectrum of flow rates

Maximum Measurement Error:

Standard: ±0.5% o.r. ± 1 mm/s

Option (Flat Spec): ±0.2% o.r. ± 2 mm/s

Medium Temperature Range (depending on Liner):

Hard Rubber: 0 to +80 °C (+32 to +176 °F)

Polyurethane: –20 to +50 °C (–4 to +122 °F)

PTFE: –20 to +90 °C (–4 to +194 °F)

Maximum Process Pressure: PN 40, Class 300, 20K

Wetted Materials:

Liners: Polyurethane, Hard Rubber, PTFE

Electrodes: 1.4435 (316L), Alloy C22 (2.4602), Tantalum .

Outputs and Communication: Modular I/O functionality with up to 3 slots. Supports 4-20mA HART, Modbus RS485, PROFIBUS PA, PROFINET, and EtherNet/IP .

Enclosure Ratings: Standard IP66/67, with optional IP68 (Type 6P) for submersion .

Key Feature: Heartbeat Technology – Enables continuous self-diagnostics, in-situ verification, and monitoring without interrupting the process .

Comprehensive E&H 5W3B Model Variants

The versatility of the E&H 5W3B electromagnetic flowmeter is reflected in its extensive range of model numbers, which denote specific nominal diameters (DN) and connection types. Below is a list of common variants available through ST-YUKE CO., LIMITED, covering everything from small processing lines to primary water distribution networks -3.

Nominal Size RangeE&H 5W3B Model Numbers
Small to Medium (DN25 – DN200)5W3B25, 5W3B32, 5W3B40, 5W3B50, 5W3B65, 5W3B80, 5W3B1H (DN100), 5W3B1Z (DN125), 5W3B1F (DN150)
Medium to Large (DN200 – DN450)5W3B2H (DN200), 5W3B2F (DN250), 5W3B3H (DN300), 5W3B3F (DN350), 5W3B4H (DN400), 5W3B4F (DN450)
Large Diameter (DN500 – DN600)5W3B5H (DN500), 5W3B6H (DN600)
Very Large Diameter (DN700 – DN900)5W3B7H (DN700), 5W3B7F (DN750), 5W3B8H (DN800), 5W3B9H (DN900)
AWWA Standards (Large Scale)5W3BV0 (AWWA 42″), 5W3BV3, 5W3BV5 (AWWA 60″), 5W3BV6, 5W3BV9
Specialty & High Capacity (DN1000+)5W3BT0 (DN1000), 5W3BT2 (DN1200), 5W3BT4 (DN1400), 5W3BT6 (DN1600), 5W3BT8 (DN1800), 5W3BE0 (DN2000), 5W3BE1, 5W3BE2 (DN2200), 5W3BE3, 5W3BE4 (DN2400), 5W3BE6, 5W3BE8, 5W3BF0, 5W3BW4, 5W3BW7, 5W3BW9

Decoding the E&H 5W3B Ordering Code: A Detailed Example

To illustrate the immense configurability of the E&H 5W3B electromagnetic flowmeter, let us break down a specific, complex product code: 5W3B25-BBEDBAAAAAAUA1KHAA2+AA .

Position 1-6: The Base Model

5W3B25: This identifies the device as a Proline Promag W 300 with a nominal diameter of DN25 (1″) .

Position 7-8: Approval Type

B: This typically signifies the device is certified for use in non-hazardous areas (Standard version).

Position 9-11: Sensor Design / Connection Type

BED: This section details the sensor mechanics.

B: Fixed flange design (as opposed to lap-joint).

E: The liner material is PTFE.

D: The electrode material is 1.4435 (316L) stainless steel.

Position 12-15: Transmitter / Electronics

BAAA: These positions cover the basic transmitter configuration. This includes power supply (e.g., 100-230V AC / 24V DC) and basic operation settings, often defaulting to a standard configuration without enhanced safety options .

Position 16-24: I/O Functionality, Display, and Housing

AAUA1KH: This is the “brain” of the device setup.

A: Output 1 is pre-configured as 4-20mA HART.

A: Output 2 is not equipped.

U: Output 3 is not equipped.

A1K: Display and Operation. This code specifies a 4-line, backlit, illuminated display with touch control. The “1K” may denote the specific language or firmware package (e.g., standard English). Some configurations include “WLAN” for wireless access

Position 25-27: Sensor Options / Calibration

AA2: This part covers calibration and sensor options.

AA: Standard calibration flow (0.5% accuracy).

2: This usually refers to a specific device model or sensor option variant, often indicating standard features without specialized customizations.

Position 28-??: Accessories & Tags (Separated by +)

+AA: This suffix indicates additional services or accessories. In this case, it likely denotes standard tagging, such as a stainless steel tag attached to the device for identification -1.

Why Choose ST-YUKE CO., LIMITED for Your E&H 5W3B?

Selecting the right configuration of an E&H 5W3B electromagnetic flowmeter requires deep product knowledge. At ST-YUKE CO., LIMITED, we specialize in helping clients navigate the complexities of the 5W3B series—from the compact 5W3B32 for auxiliary lines to the massive 5W3BE4 for primary water intake.

Our team ensures you receive the exact device for your application, configured with the correct liners, electrodes, and communication protocols (Modbus, HART, PROFINET) required by your facility. By choosing ST-YUKE CO., LIMITED, you benefit from:

Technical Expertise: Guidance on selecting the correct model from the 43+ variants.

Genuine Products: Assurance of authentic Endress+Hauser devices.

Global Logistics: Efficient shipping to project sites worldwide.

 

Obtain relevant certificates and quotations for the product

Scroll to Top

Send Us a Message