The Complete Technical Guide to the E&H 5W8C Electromagnetic Flowmeter: Battery-Powered Excellence for Remote Water Applications
In the demanding fields of water management and wastewater treatment, precision, durability, and regulatory compliance are paramount. The E&H 5W8C electromagnetic flowmeter, part of the Endress+Hauser Proline Promag W 800 series, stands as a versatile standard for volumetric flow measurement in conductive liquids where no external power source is available -1. Engineered to handle the toughest conditions—from potable water distribution to industrial effluent in remote locations—the 5W8C series delivers reliable performance with advanced diagnostic capabilities and exceptional battery longevity
As a trusted supplier, ST-YUKE CO., LIMITED offers a comprehensive range of the E&H 5W8C electromagnetic flowmeter configurations. Whether you require a compact DN25 unit for auxiliary lines or a large DN900 installation for primary water intake in off-grid locations, understanding the technical nuances of this device is crucial for optimal process integration. This guide provides an in-depth look at the technical parameters, model breakdown, and ordering code for the versatile E&H 5W8C series.
Key Technical Specifications of the E&H 5W8C Series
The E&H 5W8C electromagnetic flowmeter is engineered for bidirectional measurement of liquids with a minimum conductivity of ≥50 μS/cm . Its operation is virtually independent of pressure, density, temperature, and viscosity, making it exceptionally stable for water and wastewater applications, even with high solids content
| Parameter | Specification |
| Measuring Principle | Electromagnetic induction |
| Primary Applications | Drinking water, utility water, industrial/municipal wastewater, off-grid installations, direct underground burial, permanent underwater use |
| Nominal Diameter Range | DN 25 to DN 900 (1 to 36 inches) |
| Measuring Range | 9 dm³/min to 22,500 m³/h (2.5 to 100,000 gal/min) |
| Maximum Measurement Error | Volume flow: ±0.5% o.r. ± 2 mm/s (±0.5% o.r. ± 0.08 in/s) |
| Medium Temperature Range | Hard Rubber Liner: 0 to +70 °C (+32 to +158 °F); Polyurethane Liner: -20 to +50 °C (-4 to +122 °F); PTFE Liner: -20 to +70 °C (-4 to +158 °F) |
| Maximum Process Pressure | PN 40, Class 300, 20K |
| Minimum Conductivity | >50 μS/cm |
| Wetted Materials | Liners: Polyurethane, Hard Rubber, PTFE; Electrodes: 1.4435 (316L), Alloy C22 (2.4602), Tantalum |
| Outputs & Communication | 3x Pulse/switch output (passive); Modbus RS485; Status input; LTE Cat M1/NB1/NB2; GPRS; EGPRS; Bluetooth via SmartBlue app |
| Enclosure Ratings | Compact version: IP66/67 Type 4X and IP68 Type 6P; Sensor remote version: IP68 Type 6P with protective varnish per EN ISO 12944 C5-M/Im1/Im2/Im3 for permanent submersion or direct burial |
| Power Supply | Internal: 3.6V Lithium batteries (battery life up to 15 years); External: AC 85-265V / DC 19-30V |
| Display & Operation | 4-line backlit display with touch control (external operation); Configuration via local display or SmartBlue app; Remote data access via mail and SMS |
| Key Feature | Heartbeat Technology – Enables continuous self-diagnostics, in-situ verification, and build-up detection without interrupting the process; complies with ISO 9001:2015 for measurement traceability |
| Certifications | Drinking water approvals: ACS, KTW/W270, NSF 61, WRAS BS 6920; Custody transfer: MI-001/OIML R49 |
Comprehensive E&H 5W8C Model Variants
The versatility of the E&H 5W8C electromagnetic flowmeter is reflected in its extensive range of model numbers, which denote specific nominal diameters (DN) and connection types. Below is a list of common variants available through ST-YUKE CO., LIMITED, covering everything from small processing lines to primary water distribution networks.
| Nominal Size Range | E&H 5W8C Model Numbers |
| Small to Medium (DN25 – DN200) | 5W8C25, 5W8C32, 5W8C40, 5W8C50, 5W8C65, 5W8C80, 5W8C1H (DN100), 5W8C1Z (DN125), 5W8C1F (DN150) |
| Medium to Large (DN200 – DN450) | 5W8C2H (DN200), 5W8C2F (DN250), 5W8C3H (DN300), 5W8C3F (DN350), 5W8C4H (DN400), 5W8C4F (DN450) |
| Large Diameter (DN500 – DN900) | 5W8C5H (DN500), 5W8C6H (DN600), 5W8C7H (DN700), 5W8C7F (DN750), 5W8C8H (DN800), 5W8C9H (DN900) |
Decoding the E&H 5W8C Ordering Code: A Detailed Example
To illustrate the immense configurability of the E&H 5W8C electromagnetic flowmeter, let us break down a specific product code: 5W8C1Z-AAEAHKDE0EUD5KGAA1+CT .
Position 1-6: The Base Model
5W8C1Z: This identifies the device as a Proline Promag W 800 with a nominal diameter of DN125 (5 inches) . This medium size is ideal for municipal water distribution networks and industrial process lines requiring battery-powered operation
Position 7-8: Approval Type
AA: This signifies the device is certified for use in non-hazardous areas (Standard version), suitable for general water and wastewater applications
Position 9-11: Sensor Design / Connection Type
EAH: This section details the sensor mechanics.
E: Likely indicates a fixed flange design with specific flange standard (e.g., EN1092-1).
A: The liner material is Hard Rubber, suitable for temperatures up to +70°C and general water service -5.
H: The electrode material is 1.4435 (316L) stainless steel, providing excellent corrosion resistance for most water applications
Position 12-15: Transmitter / Electronics
KDE0: These positions cover the basic transmitter configuration, including power supply (battery-powered operation) and standard settings for the 800 series transmitter.
Position 16-24: I/O Functionality, Display, and Housing
EUD5KG: This is the “brain” of the device setup.
E: Output configuration for battery-powered operation, typically including pulse outputs for totalization.
U: Additional output specifications.
D5K: Display and Operation. This specifies a 4-line backlit display with touch control and specific language/firmware package
G: This likely refers to the sensor junction housing material, possibly AlSi10Mg coated aluminum for standard environments
Position 25-27: Sensor Options / Calibration
AA1: This part covers calibration and sensor options.
AA: Standard calibration flow (0.5% accuracy)
1: Usually refers to a specific device model or sensor option variant, indicating standard features without specialized customizations.
Position 28-??: Accessories & Tags (Separated by +)
+CT: This suffix indicates additional services or accessories. In this context, “CT” may denote Custody Transfer certification, indicating the device is configured and certified for fiscal metering applications according to MI-001/OIML R49 standards
Why Choose ST-YUKE CO., LIMITED for Your E&H 5W8C?
Selecting the right configuration of an E&H 5W8C electromagnetic flowmeter requires deep product knowledge. At ST-YUKE CO., LIMITED, we specialize in helping clients navigate the complexities of the 5W8C series—from the compact 5W8C32 for auxiliary lines to the large 5W8C9H for primary water intake in remote locations.
Our team ensures you receive the exact device for your application, configured with the correct liners, electrodes, and communication protocols (Modbus, pulse outputs, cellular communication) required by your facility. We understand the importance of certifications like NSF 61 for drinking water and IP68 for buried installations. By choosing ST-YUKE CO., LIMITED, you benefit from:
Technical Expertise: Guidance on selecting the correct model from the range of variants, including lap-joint flange options for easy installation in challenging environments
Genuine Products: Assurance of authentic Endress+Hauser devices, suitable for applications requiring international drinking water approvals, long battery life up to 15 years, and Heartbeat Technology for in-situ verification