MODEL:7F2C25-AAAABAAAAAAAALKA1+AA

Manufacturer: ENDRESS + HAUSER

Size: 100*100*100cm

Detail Specification:vortex flowmeter

Comment:Carton

Shipping Weight:30Kg

Estimated Lead Time: 12 Weeks

Payment:T/T

HS CODE:9026201090

 

product details

E&H 7F2C vortex flowmeter

Comprehensive Technical Guide: Endress+Hauser Proline Prowirl F 200 (7F2C) Vortex Flowmeter

In the landscape of industrial flow measurement, precision, reliability, and adaptability are non-negotiable. The Endress+Hauser Proline Prowirl F 200 stands as a benchmark for vortex flowmetry, specifically designed to master the challenges of measuring steam, gases, and liquids. As a trusted supplier, ST-YUKE CO., LIMITED offers the full spectrum of the E&H 7F2C vortex flowmeter series, providing solutions tailored to the most demanding applications in the chemical, energy, and utility sectors.

This guide delves deep into the technical architecture of the 7F2C series, offering a detailed analysis of its models, specifications, and ordering codes to assist engineers in making informed procurement decisions.

1. Product Overview: The Prowirl F 200 (7F2C) Advantage

The E+H Proline Prowirl F 200 (Order code family: 7F2C) is a multivariable vortex flowmeter that sets the standard for steam measurement. It distinguishes itself through the integration of Heartbeat Technology, which allows for continuous diagnostics and verification without interrupting the process.

Unlike traditional flowmeters, the 7F2C series often includes integrated temperature (DSC sensor) and pressure measurement. This allows for direct calculation of mass or energy flow, particularly critical for saturated and superheated steam applications. Its two-wire, loop-powered design ensures cost-effective installation and seamless integration into existing control systems.

Key Technical Differentiators:

Dual Sensor Technology (DSC): For simultaneous flow, temperature, and pressure measurement.

Wet Steam Detection: Uniquely capable of identifying the presence of moisture in steam, protecting downstream equipment from damage.

Robust Design: Maintenance-free with no moving parts and immunity to vibration up to 1 g in all directions.

2. The 7F2C Series: A Model for Every Application

The E&H 7F2C vortex flowmeter series is segmented into 11 primary model designators based on nominal diameter (line size) and application-specific configurations. Below is the complete list of base models available through ST-YUKE CO., LIMITED:

7F2C15 (DN 15 / ½”)

7F2C22 (DN 25 / 1″)

7F2C25 (DN 25 / 1″ – Enhanced)

7F2C26 (DN 25 / 1″ – High Pressure)

7F2C40 (DN 40 / 1 ½”)

7F2C50 (DN 50 / 2″)

7F2C80 (DN 80 / 3″)

7F2C1H (DN 100 / 4″)

7F2C1F (DN 125 / 5″)

7F2C2H (DN 150 / 6″)

7F2C2F (DN 200 / 8″)

7F2C3H (DN 250 / 10″)

7F2C3F (DN 300 / 12″)

3. Deep Dive: Decoding the 7F2C25-AAAAABAAAAAAAALKA1+AA

Understanding the E+H ordering code is critical for ensuring the device meets specific process conditions. ST-YUKE CO., LIMITED provides expert assistance in configuration, but here is a technical breakdown of a specific, complex variant: 7F2C25-AAAAABAAAAAAAALKA1+AA.

Using the standard Endress+Hauser configuration structure, we can dissect this code:

7F2C25The Base Model. This indicates the sensor is a Prowirl F 200 with a DN 25 (1″) nominal diameter. The “25” designation typically implies a standard pressure rating for this size, optimized for general-purpose steam and gas applications .

AApproval: Non-hazardous area.

AOutput: 4-20mA HART with pulse/frequency/switch output.

ADisplay & Operation: SD02 4-line backlit display with push buttons and data backup function.

AHousing: GT20 dual-chamber, aluminum coated, compact.

BElectrical Connection: Likely gland M20 (Standard).

ASensor Version: Standard DSC sensor (without exotic materials).

AMeasuring Tube Material: 316L stainless steel.

APressure Sensor Range: Standard range (e.g., 10 bar abs / 145 psi) .

AProcess Connection: EN1092-1 (PN40) flange.

ACalibration: 0.75% volume 3-point calibration.

ALanguage: English standard.

ASensor Option: Without.

LCustomized Parameterization: Pre-configured to customer settings.

KApplication Package: Standard (without special packages).

AService: Not included.

1Test/Certificate: Standard test certificate.

Interpretation:
This specific 7F2C25 configuration represents a versatile, off-the-shelf yet highly capable device for non-hazardous steam or liquid applications. It includes the essential Heartbeat Technology foundation, a full graphical display for on-site configuration, and a 316L wetted parts. It is pre-parameterized (“L” in the code), meaning ST-YUKE CO., LIMITED can supply this unit ready-to-install based on your specific process data, minimizing setup time on site.

4. Technical Specifications & Performance Data

For engineers evaluating the E&H 7F2C vortex flowmeter, precision is paramount. Below are the consolidated technical specifications:

Measurement Performance

Parameter Specification
Measurement Principle Vortex frequency (Karman vortex street)
Liquid Volume Flow Max. measurement error: ±0.75%
Steam/Gas Volume Flow Max. measurement error: ±1.00%
Mass Flow (Liquids) Max. measurement error: ±0.85%
Mass Flow (Saturated Steam) Max. measurement error: ±1.7% (temperature compensated)
Measuring Range (Liquids) 0.16 to 2412 m³/h (depending on DN)
Measuring Range (Steam/Gas) 2 to 32,166 m³/h (depending on DN)
Turndown Ratio Typically > 15:1, up to 40:1

Operating Conditions

Parameter Specification
Medium Temperature Range Standard: –40 to +260°C (–40 to +500°F)
Optional: –200 to +400°C (–328 to +752°F)
Ambient Temperature –40 to +85°C (–40 to +185°F)
Maximum Process Pressure Up to PN 100, Class 600, or 20K
Pressure Rating (High-End) Can reach PN 250 / Class 1500

Physical & Mechanical

Parameter Specification
Wetted Materials 1.4408 (CF3M), 316/316L (1.4435), Alloy C22 (2.4602)
Process Connections EN 1092-1 (B1), ASME B16.5, JIS B2220
Sensor Redundancy Optional “Dualsens” type with dual sensors and electronics

Communication & Power

Parameter Specification
Outputs 4–20 mA HART, Pulse/Frequency/Switch, PROFINET with Ethernet-APL
Protocols HART, PROFIBUS PA, FOUNDATION Fieldbus, PROFINET
Power Supply Loop-powered (two-wire)

5. Why Source Your 7F2C from ST-YUKE CO., LIMITED?

Navigating the complexities of the E&H 7F2C vortex flowmeter series—from selecting the correct 7F2C40 for high-pressure water to a 7F2C2H for main steam lines—requires a partner with deep technical insight.

ST-YUKE CO., LIMITED bridges the gap between Endress+Hauser’s advanced engineering and your specific process requirements. We offer:

Technical Configuration Support: We help decode long order strings like 7F2C1F-xxxxxxxxxxxxx to ensure you receive the correct wetted materials, approvals, and outputs.

Competitive Pricing on Full Range: Whether you require a compact 7F2C22 or a large-diameter 7F2C3F, we provide optimized sourcing solutions.

Application Expertise: Our team understands the nuances of wet steam measurement and can recommend the appropriate DSC sensor configuration for your 7F2C26 application.

 