pressure transmitter,temperature Transmitter,flow meter-ST-YK CLD

E&H 8A5C Coriolis Mass flowmeter

E&H 8A5C Coriolis Mass flowmeter

E&H 8A5C Coriolis Mass flowmeter

Ultimate Guide to ENDRESS + HAUSER 8A5C A500: Remote-Transmitter Ultra-Compact Coriolis Mass Flowmeter

In the demanding world of precision process control, the Endress+Hauser Promass 8A5C A500 series stands as the definitive solution for low-flow measurement in challenging environments. This ultra-compact Coriolis mass flowmeter features a innovative remote transmitter design, separating the sensor from the electronics to maximize installation flexibility and operational safety in hazardous or space-constrained applications -1-9. As a specialized supplier, ST-YUKE CO., LIMITED offers the full spectrum of the E&H 8A5C Coriolis mass flowmeter configurations to meet your exact application needs.

What is the E&H 8A5C Coriolis Mass Flowmeter?

The Promass 8A5C is an ultra-compact, sensor-dedicated Coriolis flowmeter from Endress+Hauser, belonging to the A 500 product family. Its defining feature is the remote transmitter version that allows the sensor and transmitter to be separated by a standard cable, enabling installation in tight spaces or high-vibration areas while maintaining easy access to the display and controls -1. It utilizes a unique, self-drainable single-tube system enabling accurate measurement of liquids and gases at the lowest flow rates and high pressures up to 430.9 bar . It delivers multivariable measurement—capturing mass flow, density, and temperature simultaneously—with Heartbeat Technology for onboard verification and compliance .

E&H 8A5C Series Overview

The 8A5C series is categorized by sensor size to cover a spectrum of low-flow applications :

E&H 8A5C01: Designed for the absolute lowest flow rates (DN1, ¹⁄₂₄”), ideal for laboratory, pilot plants, and additive processes requiring measurement of just a few grams per minute.

E&H 8A5C02: Engineered for low-flow applications (DN2, ¹⁄₁₂”) requiring high accuracy in chemical injection, batching, and control processes.

E&H 8A5C04: A compact mid-range variant (DN4, ⅛”) for slightly higher flow rates up to 450 kg/h while maintaining the ultra-compact form factor -1.

Technical Specifications at a Glance

To ensure the E&H 8A5C Coriolis mass flowmeter integrates perfectly into your system, here are the critical technical parameters based on the 8A5C series :

ParameterSpecification
Measurement PrincipleCoriolis (Single-tube system, self-drainable)
Measured VariablesMass Flow, Density, Temperature, Volume Flow (Calculated)
Measuring Range0 to 450 kg/h (0 to 16.54 lb/min)
Max. Measurement ErrorMass flow (liquid): ±0.1%
Volume flow (liquid): ±0.1%
Mass flow (gas): ±0.35%
Density (liquid): ±0.0005 g/cm³
Medium Temperature Range-50 to 205 °C (-58 to 401 °F)
Max. Process Pressure430.9 bar (6250 psi)
Wetted MaterialsMeasuring tube: Stainless steel, 1.4435 (316/316L); Alloy C22 available for corrosive media
Nominal DiameterDN 1 to 4 (¹⁄₂₄ to ⅛”)
Transmitter VersionRemote (separate) with up to 4 I/Os (Inputs/Outputs)
OperationBacklit display with touch control and WLAN access on transmitter
ConnectionSensor and transmitter connected via standard cable
Key TechnologyHeartbeat Technology for compliance verification and onboard diagnostics

Model Code Breakdown: 8A5C01-AAIBADBBGAAAAABBFBWAA2+AA

Understanding the E+H product structure is key to ordering the right unit. Here is a technical breakdown of a specific configuration available through ST-YUKE CO., LIMITED:

Full Model: 8A5C01-AAIBADBBGAAAAABBFBWAA2+AA

8A5C01: Base model (Promass A 500, ultra-compact, DN1 sensor for ultra-low flow, remote transmitter version).

A: Approval; Non-hazardous area (Standard certification).

A: Output; 4-20 mA HART with pulse/frequency/status output (remote version configuration).

I: Display; Backlit display with touch control (located on remote transmitter).

B: Housing; Sensor compact, aluminum coated; Transmitter separate.

A: Electrical connection; Gland M20 (standard on sensor).

D: Measuring tube material; Alloy C22 for enhanced corrosion resistance.

B: Process connection; (Specific high-pressure or sanitary connection type).

B: Additional options; Extended calibration.

G: Sensor version; Enhanced for extreme temperatures.

A: Transmitter housing; Field housing, aluminum coated.

A: Transmitter connection; Standard cable entry.

A: Transmitter power; Wide range AC (typically 100-240VAC).

A: Transmitter output; Configured as per standard order.

A: Transmitter software; Standard flow measurement application.

B: Language; English manual.

B: Additional cable; Standard length.

F: Cable type; Standard PVC jacket.

B: Cable termination; Standard pre-terminated ends.

W: Sensor certification; Standard material certification.

AA2: Additional options; Basic accessory package.

+AA: Extended warranty/calibration package.

Complete Ordering Examples: 8A5C Series Configurations

To illustrate the versatility of the Promass 8A5C series, ST-YUKE CO., LIMITED supplies a wide range of models. Below is a selection of valid, complete model numbers based on available configurations to assist in your procurement process:

8A5C01-AAIBABDAFAAAJDSAHAWAA2DCDD (8A5C01 for ultra-low flow, remote transmitter, stainless steel wetted parts, backlit display)

8A5C02-AAIBABDAFAAAJDSAHAWAA2DCDD (8A5C02 for low-flow applications, remote transmitter with 4 I/Os, HART output)

8A5C04-AAIBABDAFAAAJDHAHAWAA2DCDD (8A5C04 mid-range variant, remote version, extended temperature rating)

8A5C01-AAIBADBBGAAAAABBFBWAA2+AA (8A5C01 with Alloy C22 wetted parts for corrosive media, high-pressure process connection)

8A5C02-NAIBABDAFAAAJDSAHAWAA2DE (8A5C02 with specific sanitary connections for hygienic applications, ATEX approval)

8A5C04-AAIBABDAFAAAJDHAHAWAA2DE (8A5C04 with pulse/frequency output configured for gas measurement)

8A5C01-AAIBADBBGAAAAABBFBWAA2+AK (8A5C01 with enhanced certification package for hazardous area installation)

8A5C02-AAIBABDAFAAAJDCCHAWAA2DCDD (8A5C02 with extended cable length between sensor and transmitter)

8A5C04-AAIBABDAFAAAJDHAHAWAA2DCDD+AKZ1 (8A5C04 with full Heartbeat Technology verification package)

Why Choose ST-YUKE CO., LIMITED for Your E+H 8A5C?

As a specialized supplier, we bridge the gap between complex German-Swiss engineering and your operational requirements. The E&H 8A5C Coriolis mass flowmeter represents the pinnacle of low-flow measurement with its remote transmitter design, making it ideal for skid-mounted pharmaceutical systems, chemical injection packages, specialty chemical processing, and installations in hazardous or hard-to-reach locations.

ST-YUKE CO., LIMITED provides:

Exact Configuration: Assistance in decoding the E+H product structure for remote transmitter setups.

Heartbeat Technology Expertise: Guidance on leveraging onboard verification for compliance and reduced maintenance

Remote Installation Support: Pre-sales and after-sales guidance on sensor-transmitter separation and cable selection.

Genuine Supply Chain: Direct access to the full range of 8A5C01/02/04 models and configurations.

Contact ST-YUKE CO., LIMITED today to source your genuine E&H 8A5C Coriolis mass flowmeter. Provide us with any of the above model numbers, or let us help you build the right remote-transmitter configuration for your specific flow, pressure, and connection requirements.

 

 

product details

E&H 8A5C Coriolis Mass flowmeter

Ultimate Guide to ENDRESS + HAUSER 8A5C A500: Remote-Transmitter Ultra-Compact Coriolis Mass Flowmeter

In the demanding world of precision process control, the Endress+Hauser Promass 8A5C A500 series stands as the definitive solution for low-flow measurement in challenging environments. This ultra-compact Coriolis mass flowmeter features a innovative remote transmitter design, separating the sensor from the electronics to maximize installation flexibility and operational safety in hazardous or space-constrained applications -1-9. As a specialized supplier, ST-YUKE CO., LIMITED offers the full spectrum of the E&H 8A5C Coriolis mass flowmeter configurations to meet your exact application needs.

What is the E&H 8A5C Coriolis Mass Flowmeter?

The Promass 8A5C is an ultra-compact, sensor-dedicated Coriolis flowmeter from Endress+Hauser, belonging to the A 500 product family. Its defining feature is the remote transmitter version that allows the sensor and transmitter to be separated by a standard cable, enabling installation in tight spaces or high-vibration areas while maintaining easy access to the display and controls -1. It utilizes a unique, self-drainable single-tube system enabling accurate measurement of liquids and gases at the lowest flow rates and high pressures up to 430.9 bar . It delivers multivariable measurement—capturing mass flow, density, and temperature simultaneously—with Heartbeat Technology for onboard verification and compliance .

E&H 8A5C Series Overview

The 8A5C series is categorized by sensor size to cover a spectrum of low-flow applications :

E&H 8A5C01: Designed for the absolute lowest flow rates (DN1, ¹⁄₂₄”), ideal for laboratory, pilot plants, and additive processes requiring measurement of just a few grams per minute.

E&H 8A5C02: Engineered for low-flow applications (DN2, ¹⁄₁₂”) requiring high accuracy in chemical injection, batching, and control processes.

E&H 8A5C04: A compact mid-range variant (DN4, ⅛”) for slightly higher flow rates up to 450 kg/h while maintaining the ultra-compact form factor -1.

Technical Specifications at a Glance

To ensure the E&H 8A5C Coriolis mass flowmeter integrates perfectly into your system, here are the critical technical parameters based on the 8A5C series :

ParameterSpecification
Measurement PrincipleCoriolis (Single-tube system, self-drainable)
Measured VariablesMass Flow, Density, Temperature, Volume Flow (Calculated)
Measuring Range0 to 450 kg/h (0 to 16.54 lb/min)
Max. Measurement ErrorMass flow (liquid): ±0.1%
Volume flow (liquid): ±0.1%
Mass flow (gas): ±0.35%
Density (liquid): ±0.0005 g/cm³
Medium Temperature Range-50 to 205 °C (-58 to 401 °F)
Max. Process Pressure430.9 bar (6250 psi)
Wetted MaterialsMeasuring tube: Stainless steel, 1.4435 (316/316L); Alloy C22 available for corrosive media
Nominal DiameterDN 1 to 4 (¹⁄₂₄ to ⅛”)
Transmitter VersionRemote (separate) with up to 4 I/Os (Inputs/Outputs)
OperationBacklit display with touch control and WLAN access on transmitter
ConnectionSensor and transmitter connected via standard cable
Key TechnologyHeartbeat Technology for compliance verification and onboard diagnostics

Model Code Breakdown: 8A5C01-AAIBADBBGAAAAABBFBWAA2+AA

Understanding the E+H product structure is key to ordering the right unit. Here is a technical breakdown of a specific configuration available through ST-YUKE CO., LIMITED:

Full Model: 8A5C01-AAIBADBBGAAAAABBFBWAA2+AA

8A5C01: Base model (Promass A 500, ultra-compact, DN1 sensor for ultra-low flow, remote transmitter version).

A: Approval; Non-hazardous area (Standard certification).

A: Output; 4-20 mA HART with pulse/frequency/status output (remote version configuration).

I: Display; Backlit display with touch control (located on remote transmitter).

B: Housing; Sensor compact, aluminum coated; Transmitter separate.

A: Electrical connection; Gland M20 (standard on sensor).

D: Measuring tube material; Alloy C22 for enhanced corrosion resistance.

B: Process connection; (Specific high-pressure or sanitary connection type).

B: Additional options; Extended calibration.

G: Sensor version; Enhanced for extreme temperatures.

A: Transmitter housing; Field housing, aluminum coated.

A: Transmitter connection; Standard cable entry.

A: Transmitter power; Wide range AC (typically 100-240VAC).

A: Transmitter output; Configured as per standard order.

A: Transmitter software; Standard flow measurement application.

B: Language; English manual.

B: Additional cable; Standard length.

F: Cable type; Standard PVC jacket.

B: Cable termination; Standard pre-terminated ends.

W: Sensor certification; Standard material certification.

AA2: Additional options; Basic accessory package.

+AA: Extended warranty/calibration package.

Complete Ordering Examples: 8A5C Series Configurations

To illustrate the versatility of the Promass 8A5C series, ST-YUKE CO., LIMITED supplies a wide range of models. Below is a selection of valid, complete model numbers based on available configurations to assist in your procurement process:

8A5C01-AAIBABDAFAAAJDSAHAWAA2DCDD (8A5C01 for ultra-low flow, remote transmitter, stainless steel wetted parts, backlit display)

8A5C02-AAIBABDAFAAAJDSAHAWAA2DCDD (8A5C02 for low-flow applications, remote transmitter with 4 I/Os, HART output)

8A5C04-AAIBABDAFAAAJDHAHAWAA2DCDD (8A5C04 mid-range variant, remote version, extended temperature rating)

8A5C01-AAIBADBBGAAAAABBFBWAA2+AA (8A5C01 with Alloy C22 wetted parts for corrosive media, high-pressure process connection)

8A5C02-NAIBABDAFAAAJDSAHAWAA2DE (8A5C02 with specific sanitary connections for hygienic applications, ATEX approval)

8A5C04-AAIBABDAFAAAJDHAHAWAA2DE (8A5C04 with pulse/frequency output configured for gas measurement)

8A5C01-AAIBADBBGAAAAABBFBWAA2+AK (8A5C01 with enhanced certification package for hazardous area installation)

8A5C02-AAIBABDAFAAAJDCCHAWAA2DCDD (8A5C02 with extended cable length between sensor and transmitter)

8A5C04-AAIBABDAFAAAJDHAHAWAA2DCDD+AKZ1 (8A5C04 with full Heartbeat Technology verification package)

Why Choose ST-YUKE CO., LIMITED for Your E+H 8A5C?

As a specialized supplier, we bridge the gap between complex German-Swiss engineering and your operational requirements. The E&H 8A5C Coriolis mass flowmeter represents the pinnacle of low-flow measurement with its remote transmitter design, making it ideal for skid-mounted pharmaceutical systems, chemical injection packages, specialty chemical processing, and installations in hazardous or hard-to-reach locations.

ST-YUKE CO., LIMITED provides:

Exact Configuration: Assistance in decoding the E+H product structure for remote transmitter setups.

Heartbeat Technology Expertise: Guidance on leveraging onboard verification for compliance and reduced maintenance

Remote Installation Support: Pre-sales and after-sales guidance on sensor-transmitter separation and cable selection.

Genuine Supply Chain: Direct access to the full range of 8A5C01/02/04 models and configurations.

Contact ST-YUKE CO., LIMITED today to source your genuine E&H 8A5C Coriolis mass flowmeter. Provide us with any of the above model numbers, or let us help you build the right remote-transmitter configuration for your specific flow, pressure, and connection requirements.

 

 

Obtain relevant certificates and quotations for the product

Scroll to Top

Send Us a Message