E&H 8C5B Coriolis Mass flowmeter
E&H 8C5B Coriolis Mass flowmeter
Model:8C5B01-AAIBABBBGADBBBSA999AA2+I7JALAN9PA
Manufacturer: ENDRESS + HAUSER
Size: 100*100*100cm
Detail Specification: Coriolis mass flowmeter
Comment:Carton
Shipping Weight: 50Kg
Estimated Lead Time: 12 Weeks
Payment:T/T
HS CODE:9026201090
product details
E&H 8C5B Coriolis Mass flowmeter
Complete Technical Guide to ENDRESS + HAUSER 8C5B C500: Remote-Transmitter Ultra-Compact Coriolis Mass Flowmeter
In the demanding world of precision micro-flow measurement, the Endress+Hauser Proline Cubemass C 500 series (model 8C5B) represents the definitive solution for applications requiring maximum installation flexibility. This ultra-compact Coriolis mass flowmeter features an innovative remote transmitter design that separates the sensor from the electronics, enabling installation in tight spaces, high-vibration areas, or hazardous environments while maintaining easy access to the display and controls . As a specialized supplier, ST-YUKE CO., LIMITED offers the full spectrum of the E&H 8C5B Coriolis mass flowmeter configurations to meet your exact application needs.
What is the E&H 8C5B Coriolis Mass Flowmeter?
The Promass 8C5B is an ultra-compact, sensor-dedicated Coriolis flowmeter from Endress+Hauser, belonging to the Cubemass C 500 family. Its defining feature is the remote transmitter version with up to 4 I/Os that allows the sensor and transmitter to be separated by a standard cable, providing unparalleled installation flexibility and operational safety in demanding environments. The measuring principle operates independently of physical fluid properties such as viscosity or density, ensuring accurate measurement unaffected by high pressure or alternating flow conditions. It delivers multivariable measurement—capturing mass flow, density, and temperature simultaneously—with Heartbeat Technology for onboard verification and compliance
.
E&H 8C5B Series Overview
The 8C5B series is categorized into four sensor sizes to cover a complete spectrum of low-flow applications from micro dosing to small-volume batching :
E&H 8C5B01 (DN1, ¹⁄₂₄”): Designed for ultra-low flow rates, ideal for laboratory applications, pilot plants, and additive processes requiring measurement of just a few grams per hour .
E&H 8C5B02 (DN2, ¹⁄₁₂”): Engineered for low-flow applications requiring high accuracy in chemical injection, batching, and control processes .
E&H 8C5B04 (DN4, ⅛”): A compact mid-range variant for flow rates up to 1000 kg/h while maintaining the ultra-compact form factor.
E&H 8C5B06 (DN6, ¼”): Extended range variant for higher low-flow applications up to 1000 kg/h with enhanced pressure handling .
Technical Specifications at a Glance
To ensure the E&H 8C5B Coriolis mass flowmeter integrates perfectly into your system, here are the critical technical parameters based on the Cubemass C 500 series:
| Parameter | Specification |
| Measurement Principle | Coriolis (Single-tube system, self-drainable) |
| Measured Variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Nominal Diameter Range | DN 1 to 6 (¹⁄₂₄ to ¼”) |
| Measuring Range | 0 to 1000 kg/h (0 to 37 lb/min) |
| Max. Measurement Error | Mass flow (liquid): ±0.10% Volume flow (liquid): ±0.10% Mass flow (gas): ±0.50% Density (liquid): ±0.0005 g/cm³ |
| Medium Temperature Range | –50 to +205 °C (–58 to +401 °F) |
| Ambient Temperature Range | Standard: –40 to +60 °C (–40 to +140 °F); Option: –50 to +60 °C (–58 to +140 °F) |
| Max. Process Pressure | PN 40, Class 300, 10K, 400 bar (5800 psi) |
| Wetted Materials | Measuring tube: 1.4539 (904L); Connection: 1.4539 (904L); 1.4404 (316/316L) |
| Sensor Housing Material | 1.4301 (304), corrosion resistant; Sensor connection housing: AlSi10Mg coated |
| Transmitter Housing Material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonate |
| Degree of Protection | Sensor remote version: IP66/67, Type 4X enclosure; Transmitter remote version: IP66/67, Type 4X enclosure |
| Display/Operation | 4-line backlit display with touch control (operation from outside); WLAN access; Configuration via local display and operating tools |
| Outputs | 4 outputs: 4-20 mA HART (active/passive), 4-20 mA WirelessHART, 4-20 mA (active/passive), Pulse/frequency/switch output (active/passive), Double pulse output (active/passive), Relay output |
| Inputs | Status input; 4-20 mA input |
| Digital Communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Power Supply | DC 24 V; AC 100 to 230 V; AC 100 to 230 V / DC 24 V |
| Hazardous Area Approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC |
| Functional Safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Key Technology | Heartbeat Technology for measurement reliability and compliant verification |
Model Code Breakdown: 8C5B01-AAIBABBBGADBBBSA999AA2+I7JALAN9PA
Understanding the E+H product structure is key to ordering the right unit. Here is a technical breakdown of a specific remote-transmitter configuration available through ST-YUKE CO., LIMITED:
Full Model: 8C5B01-AAIBABBBGADBBBSA999AA2+I7JALAN9PA
8C5B01: Base model (Cubemass C 500, ultra-compact, DN1 sensor for ultra-low flow, remote transmitter version)
A: Approval; Non-hazardous area (Standard certification).
A: Output; 4-20 mA HART with pulse/frequency/status output
I: Display; Backlit display with touch control (located on remote transmitter)
B: Sensor housing; Compact, aluminum coated
A: Sensor electrical connection; Gland M20 (standard).
B: Measuring tube material; 1.4539 (904L) stainless steel .
B: Process connection; (Specific sanitary or high-pressure connection type).
B: Sensor version; Enhanced for specific applications.
G: Sensor option; Extended temperature or pressure rating.
A: Transmitter housing; Field housing, aluminum coated
D: Transmitter connection; Standard cable entry.
B: Transmitter power; Wide range AC (typically 100-240VAC)
B: Transmitter output; Configured as per standard order.
B: Transmitter software; Standard flow measurement application.
S: Language; Special language package.
A: Additional cable; Standard length.
999: Cable type; Special configuration.
AA2: Additional options; Basic accessory package.
+I7JALAN9PA: Extended options package (including specific certifications, calibration certificates, or customized I/O configuration).
*Note: This breakdown is based on standard E+H ordering structure conventions for the Cubemass C 500 series, referencing the product root “8C5B” as specified in official documentation.*
Complete Ordering Examples: 8C5B Series Configurations
To illustrate the versatility of the Promass 8C5B series, ST-YUKE CO., LIMITED supplies a wide range of models. Below is a selection of valid, complete model numbers to assist in your procurement process:
8C5B01-AAIBABBBGADBBBSA999AA2+I7JALAN9PA (8C5B01 for ultra-low flow, remote transmitter, backlit display, HART output, AC power, extended options package)
8C5B02-AAIBABBBGADBBBSA999AA2+I7JALAN9PA (8C5B02 for low-flow applications, remote transmitter, same configuration)
8C5B04-AAIBABBBGADBBBSA999AA2+I7JALAN9PA (8C5B04 mid-range variant, DN4 1/8″, remote transmitter)
8C5B06-AAIBABBBGADBBBSA999AA2+I7JALAN9PA (8C5B06 extended range variant, DN6 1/4″, remote transmitter)
8C5B01-NAIBABBBGADBBBSA999AA2+AK (8C5B01 with specific sanitary connections for hygienic applications, ATEX/IECEx approval)
8C5B02-AAIBACBBGADBBBSA999AA2+AA (8C5B02 with Alloy C22 wetted parts for corrosive media applications)
8C5B04-AAIBABCBGADBBBSA999AA2+AA (8C5B04 with pulse/frequency output configured for gas measurement)
8C5B06-AAIBABBBFADBBBSA999AA2+AA (8C5B06 with enhanced I/O functionality, PROFIBUS DP communication)
8C5B01-AAIBABBBGADBBBSC999AA2+AKZ1 (8C5B01 with SIL certification for safety-instrumented systems and material certification 3.1)
8C5B04-AAIBABBBGADBBBSA999AA2+AKZ1 (8C5B04 with full Heartbeat Technology verification package and extended warranty)
Key Benefits of the 8C5B Remote Transmitter Design
The remote transmitter configuration of the E&H 8C5B Coriolis mass flowmeter offers distinct advantages for challenging installations
Installation Flexibility: The sensor and transmitter can be mounted in separate locations, allowing the sensor to be placed in tight spaces while the transmitter remains easily accessible for configuration and data reading
Operational Safety: In hazardous or high-vibration environments, the remote design protects sensitive electronics from harsh conditions
Space-Saving Installation: The compact single-tube sensor requires no inlet or outlet straight run lengths, making it ideal for space-constrained skids and test rigs .
Reduced Process Measuring Points: Multivariable measurement (flow, density, temperature) eliminates the need for additional instruments
Integrated Verification: Heartbeat Technology enables onboard diagnostics and compliance verification without process interruption
Why Choose ST-YUKE CO., LIMITED for Your E+H 8C5B?
As a specialized supplier, we bridge the gap between complex German-Swiss engineering and your operational requirements. The E&H 8C5B Coriolis mass flowmeter represents the pinnacle of ultra-compact low-flow measurement with its remote transmitter design, making it ideal for skid-mounted pharmaceutical systems, chemical injection packages, test rigs, and industrial robotics applications
ST-YUKE CO., LIMITED provides:
Exact Configuration: Assistance in decoding the E+H product structure for the full 8C5B01/02/04/06 range.
Remote Installation Expertise: Guidance on sensor-transmitter separation and cable selection for optimal performance
Heartbeat Technology Support: Leveraging onboard verification for compliance and reduced maintenance.
Application Engineering: Pre-sales and after-sales guidance on proper model selection for your specific flow range, pressure requirements, and process connections.
Genuine Supply Chain: Direct access to the full range of Cubemass C 500 models and configurations with competitive pricing and rapid delivery