Complete Technical Guide to E&H 8F1B Compact Coriolis Mass Flowmeter
Product Overview: Endress+Hauser Proline Promass F 100 (8F1B Series)
The Endress+Hauser Proline Promass F 100, designated by the model series 8F1B, is a premium Coriolis mass flowmeter featuring an ultra-compact transmitter designed for applications requiring highest measurement performance under varying and demanding process conditions . This instrument combines the renowned Promass F sensor—known for its robustness and immunity to fluctuating environments—with the smallest transmitter housing available today, delivering full functionality on an exceptionally small footprint .
The E&H 8F1B Coriolis mass flowmeter provides multivariable measurement capability, simultaneously capturing mass flow, density, and temperature in a single device, thereby reducing the need for multiple process measuring points . What distinguishes this model is its premium accuracy of ±0.05% for liquid mass flow (with PremiumCal option) and its ability to operate independently of physical fluid properties such as viscosity or density . The instrument requires no inlet or outlet straight runs, offering unparalleled flexibility for system integrators, skid builders, and equipment manufacturers working in space-constrained installations .
Built-in Heartbeat Technology enables continuous self-diagnostics and on-site verification without process interruption, ensuring compliance and extending recalibration cycles while meeting ISO 9001 traceability requirements . The transmitter features an integrated web server for time-saving local operation without additional software or hardware.
With over two decades of experience in industrial instrumentation supply, ST-YUKE CO., LIMITED is proud to offer this high-precision instrument to clients worldwide seeking the ultimate in Coriolis flow measurement performance combined with compact design.
Model Series Overview: 8F1B Product Range
The E&H 8F1B series encompasses nine nominal diameter variants to accommodate diverse flow rate requirements across industrial applications. Promass F has a long-standing reputation as a highly accurate device under varying process conditions, suited for the broadest range of applications .
| Model Variant | Nominal Diameter | Typical Applications |
| 8F1B08 | DN 8 (3/8″) | Low flow laboratory, pilot plants, additive injection |
| 8F1B2F | DN 15 (1/2″) | Chemical injection, small batch processes |
| 8F1B15 | DN 15 (1/2″) | Chemical injection, pharmaceutical manufacturing |
| 8F1B25 | DN 25 (1″) | General chemical processing, blending operations |
| 8F1B40 | DN 40 (1½”) | Main process lines, medium-volume batching |
| 8F1B50 | DN 50 (2″) | Bulk transfer, large-volume processes |
| 8F1B80 | DN 80 (3″) | Heavy industrial applications, main plant lines |
| 8F1B1H | DN 100 (4″) | High-capacity transfer, large-scale processing |
| 8F1B1F | DN 150 (6″) | Very high flow, main distribution lines |
All variants share the same fundamental specifications including premium accuracy, multivariable measurement, ultra-compact transmitter design, and Heartbeat Technology diagnostics
Comprehensive Technical Specifications
Understanding the technical parameters is essential for selecting the optimal model for your specific application requirements. Below are the detailed specifications for the E&H 8F1B Coriolis flowmeter series:
General Specifications
Measurement Principle: Coriolis mass flow
Nominal Diameter Range: DN 8 to 250 (⅜ to 10 inches)
Measuring Range: 0 to 2,200,000 kg/h (0 to 80,840 lb/min)
Measurement Variables: Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Measurement Accuracy
Mass Flow (Liquid): ±0.1% (standard), ±0.05% (PremiumCal option)
Volume Flow (Liquid): ±0.1%
Mass Flow (Gas): ±0.25%
Density (Liquid): ±0.0005 g/cm³
Operating Conditions
Medium Temperature Range: Standard: –50 to +150 °C (–58 to +302 °F); Option: –50 to +240 °C (–58 to +464 °F)
Ambient Temperature Range: Standard: –40 to +60 °C (–40 to +140 °F); Option: –50 to +60 °C (–58 to +140 °F)
Maximum Process Pressure: PN 100, Class 600, 63K
Secondary Containment Rating: Up to 40 bar (580 psi)
Materials of Construction
Measuring Tube Material: 1.4539 (904L) stainless steel; 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Process Connection Material: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Sensor Housing Material: 1.4301 (304) stainless steel, corrosion-resistant
Transmitter Housing Material: Powder-coated die-cast aluminum; optional stainless steel hygienic housing available
Enclosure Rating: IP66/67, Type 4X; IP69K available for hygienic applications
Electrical Specifications
Output Signals (modular):
4-20 mA HART (active/passive)
Pulse/frequency/switch output (passive)
Dual pulse output
Relay output
Digital Communication: HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
Power Supply: DC 20 to 30 V
Display and Operation
Display: 4-line backlit display available (no local operation on some variants)
Operation: Configuration via web browser and operating tools; integrated web server
Additional Features: Data backup function, remote display unit available
Certifications and Approvals
Hazardous Area: ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC
Functional Safety: SIL compliant per IEC 61508 for use in safety applications per IEC 61511
Pressure: PED, CRN
Material Certification: 3.1 material certificates, NACE MR0175/MR0103
Product Safety: CE, C-Tick, EAC marking
Marine Approvals: ABS, BV, DNV GL, LR
Hygienic Certifications: 3-A, EHEDG
Calibration: Accredited calibration per ISO/IEC 17025
Heartbeat Technology: TÜV-attested compliance with ISO 9001:2015 measurement traceability requirements
Complete Model Number Decoding: 8F1B08-AAIBAAAAFAAAAASAAASAA2+AAC9
Endress+Hauser employs a structured ordering system that provides complete specification of the instrument through the model code. Understanding this structure is crucial for ensuring you receive the exact configuration required for your application. Below is the detailed breakdown of 8F1B08-AAIBAAAAFAAAAASAAASAA2+AAC9:
Ordering Code Structure
The general structure follows: 8F1B (Product Series) + Nominal Diameter + Approval + Power Supply + Output 1 + Output 2 + Output 3 + Output 4 + Display/Operation + Housing + Electrical Connection + Material + Process Connection + Calibration + Device Model + Language + Options + Application Package + Service + Test Certificate + Additional Options
Detailed Position-by-Position Analysis
| Position | Code Segment | Description and Technical Interpretation |
| 1-4 | 8F1B | Product Series: Proline Promass F 100 / Premium compact Coriolis mass flowmeter with ultra-compact transmitter |
| 5-6 | 08 | Nominal Diameter: DN 8 (3/8″) – Suitable for low flow rate applications |
| 7 | A | Approval: Non-hazardous area – Standard certification for general-purpose installations |
| 8 | A | Power Supply: 100-230 VAC / 24 VDC – Universal power supply for global use |
| 9 | I | Output 1: 4-20mA HART – Standard analog communication with HART protocol |
| 10 | B | Output 2: Without – No second output configured |
| 11 | A | Output 3: Without – No third output configured |
| 12 | A | Output 4: Without – No fourth output configured |
| 13 | A | Display/Operation: Without; via communication – No local display, configured via digital communication |
| 14 | A | Housing: Aluminum coated – Standard aluminum housing with protective coating |
| 15 | A | Electrical Connection: Thread NPT 1/2″ – Standard North American conduit connection |
| 16 | A | Measuring Tube Material: Stainless steel 1.4539 (904L) – Standard tube material |
| 17 | S | Process Connection: To be specified – Connection type determined separately |
| 18 | A | Calibration Flow: Standard calibration – Factory standard accuracy (0.1%) |
| 19 | A | Device Model: Model 1 – Base device configuration |
| 20 | A | Language: None (English standard) – Factory default English documentation |
| 21 | S | Sensor Options: Without – Standard sensor configuration |
| 22 | A | Customized Parameterization: Without – Factory default parameters |
| 23 | A | Application Package: Without – No special application software |
| 24 | S | Service: Without – Standard warranty terms |
| 25 | A | Test Certificate: Without – Standard factory test documentation |
| 26 | A | Accessory Mounted: Without – No pre-mounted accessories |
| 27 | 2 | Accessory Enclosed: Without – No enclosed accessories |
| 28 | + | Separator: Plus sign separating main code from additional options |
| 29-32 | AAC9 | Additional Options: Extended configuration package – Specific application settings or accessories |
Popular Complete Model Configurations
Based on market demand and application requirements, certain configurations of the E&H 8F1B series are more frequently specified. The following table presents a selection of complete model numbers representing popular configurations across different nominal sizes:
| Nominal Size | Complete Model Number Example | Configuration Highlights |
| DN 8 (3/8″) | 8F1B08-AAIBAAAAFAAAAASAAASAA2+AAC9 | Non-hazardous; universal power supply; 4-20mA HART; no display; NPT 1/2″; stainless steel; extended options |
| DN 8 (3/8″) | 8F1B08-C4DNBBLSCFDWA+ | Premium configuration with specific approvals; suitable for demanding applications |
| DN 15 (1/2″) | 8F1B15-AAIBABAAADSACWSJA2 | Non-hazardous; 4-20mA HART with second output; NPT 1/2″; 0.1% accuracy |
| DN 25 (1″) | 8F1B25-10E3/0 | Hygienic version with stainless steel tri-clamp fitting; 24VDC; 0.10% accuracy; ideal for sanitary applications |
| DN 25 (1″) | 8F1B25-AAIBABAAADSACWSJA2 | Non-hazardous; 4-20mA HART; dual output configuration; standard accuracy |
| DN 40 (1½”) | 8F1B40-AADBBADSAAASA | Non-hazardous; 4-20mA HART with pulse/frequency output; display included; NPT 1/2″; ASME B16.5 Class 150 flanges; 0.10% accuracy |
| DN 50 (2″) | 8F1B50-AAIBABAAADSACWSJA2 | Non-hazardous; 4-20mA HART; dual output; suitable for high-flow applications |
| DN 80 (3″) | 8F1B80-AAIBABAAADSACWSJA2 | Non-hazardous; 4-20mA HART; dual output; heavy industrial applications |
| DN 100 (4″) | 8F1B1H-XXXXXXXXXXX | High-capacity configuration for large-volume processing |
| DN 150 (6″) | 8F1B1F-XXXXXXXXXXX | Very high-flow configuration for main distribution lines |
Key Technical Advantages
Premium Accuracy
The 8F1B series delivers exceptional measurement performance with mass flow accuracy of ±0.05% (PremiumCal option), making it one of the most precise Coriolis flowmeters available for liquid applications . Gas flow measurement achieves ±0.25% accuracy, ensuring reliable performance across all media types.
Ultra-Compact Transmitter Design
Featuring the smallest transmitter housing available today, the 8F1B delivers full functionality on an exceptionally small footprint, making it the preferred choice for system integrators, skid builders, and equipment manufacturers working in space-constrained installations . An extra-compact stainless steel hygienic housing allows placement into the most compact rigs.
True Multivariable Measurement
The 8F1B series simultaneously measures mass flow, density, and temperature, eliminating the need for separate instruments and reducing both capital expenditure and installation complexity.
Heartbeat Technology for Continuous Verification
The integrated Heartbeat Technology enables continuous self-diagnosis during operation, on-demand device verification without process interruption, and predictive maintenance capabilities based on actual device health . This technology is TÜV-attested for measurement traceability according to ISO 9001:2015 requirements .
Installation Flexibility
The compact sensor design requires no upstream or downstream straight pipe runs, offering unparalleled flexibility in system design and retrofitting applications. This feature is particularly valuable in skid-mounted systems and space-constrained installations.
Measurement Principle Independence
The Coriolis measurement principle operates independently of physical fluid properties such as viscosity, density, pressure, temperature, and conductivity, ensuring consistent accuracy across varying process conditions .
Robust Design for Harsh Environments
With IP66/67 enclosure rating and robust construction from corrosion-resistant materials, the 8F1B series is engineered to withstand demanding industrial environments. High ingress protection up to IP69K is available for hygienic applications .
Applications and Industries
The E&H 8F1B Coriolis mass flowmeter is ideally suited for:
Chemical Industry: High-precision liquid and gas measurement under varying process conditions
Petrochemical Processing: Mass balance, blending, and process monitoringPharmaceutical Manufacturing: Batch processing and ingredient dosing with hygienic options
Food and Beverage: Sanitary process applications with 3-A/EHEDG certifications
Oil and Gas: Production monitoring and distribution systems
Water and Wastewater: Treatment chemical dosing and monitoring
System Integration: Skid building and equipment manufacturing requiring compact designWhy Partner with ST-YUKE CO., LIMITED?
With over two decades of specialized experience in industrial instrumentation supply, ST-YUKE CO., LIMITED has established itself as a trusted partner for process automation solutions worldwide. Our expertise in the E&H 8F1B Coriolis mass flowmeter series enables us to provide:
20+ Years of Industry Expertise
Our team possesses deep understanding of process measurement challenges across multiple industries, allowing us to provide informed guidance on instrument selection, configuration, and application optimization.
Comprehensive Technical Support
We offer end-to-end technical support, from initial product selection through post-installation troubleshooting. Our technical staff can assist with model code interpretation, specification verification, and application engineering.
Global Supply Chain Capabilities
Leveraging our long-standing relationships with manufacturers and distributors worldwide, we ensure competitive pricing and reliable delivery for the full range of E&H 8F1B configurations, including all nine size variants from DN8 to DN150.
Customized Solutions
We recognize that every application has unique requirements. ST-YUKE CO., LIMITED works closely with clients to identify the optimal configuration—whether standard or specialized—ensuring perfect fit for your process conditions.
Commitment to Quality
Our 20-year track record in industrial supply is built on a foundation of quality assurance and customer satisfaction. We stand behind every product we supply, ensuring you receive genuine, factory-specified instrumentation.
Contact Information
For technical consultation, quotations, or application assistance regarding the E&H 8F1B Coriolis mass flowmeter series, please contact:
ST-YUKE CO., LIMITED
Industrial Instrumentation Specialists – Serving Global Industries for Over 20 Years
Our technical sales team is available to discuss your specific requirements, provide model code assistance, and deliver competitive pricing for all 8F1B variants, including 8F1B08, 8F1B2F, 8F1B15, 8F1B25, 8F1B40, 8F1B50, 8F1B80, 8F1B1H, and 8F1B1F configurations.