pressure transmitter,temperature Transmitter,flow meter-ST-YK CLD

E&H 8P5B Coriolis Mass flowmeter

E&H 8S5B Coriolis mass flowmeter

Model:8S5B15-BSDBABBBG9AAAASBAAWAA2

Manufacturer: ENDRESS + HAUSER

Size: 100*100*100cm

Detail Specification: Coriolis mass flowmeter

Comment:Carton

Shipping Weight: 50Kg

Estimated Lead Time: 12 Weeks

Payment:T/T

HS CODE:9026201090

product details

E&H 8P5B Coriolis Mass flowmeter

 

Comprehensive Technical Guide: E&H 8P5B Coriolis Mass Flowmeter (Promass P 500)

Supplier: ST-YUKE CO., LIMITED

In the demanding fields of life sciences, biopharmaceuticals, and food processing, precision and hygiene are non-negotiable. The Endress+Hauser Proline Promass P 500 is the benchmark for sterile Coriolis flow measurement. Specifically identified by the product root E&H 8P5B, this remote-type flowmeter is engineered for applications requiring strict compliance with sanitary standards, offering unmatched multivariable measurement (mass flow, density, and temperature) in a compact, drainable design -6.

As a leading supplier, ST-YUKE CO., LIMITED offers the full range of E&H 8P5B series with authentic configurations and expert technical support.

Product Series Overview: The 8P5B Family

The Promass P 500 series is designed for inline installations under sterile conditions. It features a low-ferrite content 1.4435 (316L) stainless steel measuring tube with an electropolished surface, ensuring fast recovery from CIP (Clean-in-Place) and SIP (Sterilize-in-Place) cycles -1-4. The “8P5B” root code specifically denotes the remote transmitter version (P 500) with the sensor, allowing for flexible installation in harsh environments.

The series is divided into five primary sensor sizes to cover a wide range of flow rates:

Model RootNominal DiameterProcess Connection ReferenceTypical Flow Application
8P5B08DN 8 / 3/8″Micro dosingUltra-low flow rates
8P5B15DN 15 / 1/2″Sanitary ClampLow flow, pilot plants
8P5B25DN 25 / 1″Flange / ClampStandard batching
8P5B40DN 40 / 1 1/2″Flange / ClampMedium volume transfer
8P5B50DN 50 / 2″Flange / ClampHigh volume production lines

In-Depth Model Code Breakdown: 8P5B25-AAIBABBBGAAABBBCBEABA2

To fully understand the capabilities of this instrument, it is essential to decode the feature stack in the model number. Below is the technical breakdown of a high-specification model: 8P5B25-AAIBABBBGAAABBBCBEABA2 .

This specific configuration represents a DN25 flowmeter built for high-accuracy mass flow with enhanced diagnostic capabilities, ideal for critical biotech applications.

  • 8P5B25: Base Model
    • 8P5B: Product family (Promass P, 500 series, remote version).
  • 25: Nominal diameter DN25 (1″) -3-4.
  • A: Approval
    • A: Non-hazardous area / ordinary location -1.
  • A: Power Supply
    • A: 100-230V AC / 24V DC (wide range power for global compatibility) -6.
  • I: Output 1
    • I: 4-20mA HART (analog with digital communication protocol) -1.
  • B: Output 2
    • B: Pulse / Frequency / Switch output (configurable for totalization or batching).
  • A: Output 3
    • A: Not assigned (basic configuration with two outputs).
  • B: Output 4
    • B: Not assigned (reserved slot).
  • B: Display; Operation
    • B: 4-line backlit display; touch control (allows operation without opening the housing) -1-6.
  • B: Housing
    • B: Aluminum, coated (standard robust material for the transmitter).
  • G: Sensor Connection Housing
    • G: Hygienic version, stainless steel (316L) – essential for wash-down areas, offering IP69 protection 
  • A: Cable Entry
    • A: M20 gland (standard metric entry).
  • A: Measuring Tube Material
    • A: Stainless steel, 0.38µm (electropolished) – Specifically designed for life sciences to prevent bacterial growth.
  • A: Process Connection; Material
    • A: The specific connection is detailed in the “feature” part of the code (see next segment).
  • A: Calibration; Flow
    • A: 0.10% (Master precision for mass flow) 
  • B: Extended Order Code 1
    • B: This position kicks off the detailed “feature” string that follows the main code.
  • B: Feature 1 (Process Connection)
    • B: ISO2852 clamp, DIN11866 series B (standard sanitary clamp for food/pharma) -1.
  • B: Feature 2 (Process Connection Material)
    • B: 1.4435 (316L) stainless steel.
  • C: Feature 3 (Application Package)
    • C: “Application” package (may include specific batching or concentration software).
  • B: Feature 4 (Application Detail)
    • B / E: Extended HistoROM / Heartbeat Verification + Monitoring (onboard data logging and on-demand verification without process interruption) 
  • A: Feature 5 (Application Detail)
    • A / B: Standard configuration.
  • 2: Feature 6 (Additional Testing; Certificate)
    • 2: The final digit indicates the inclusion of a 3.1 material certificate and surface finish test certification per ISO4287 (EN10204 3.1) 

Diverse Configuration Examples (Complete Model Numbers)

To illustrate the modularity of the 8P5B series, here are several valid, complete order codes available through ST-YUKE CO., LIMITED. These variations cater to different process connections and output requirements.

  1. 8P5B40-AAIBAAAAFAAAAATDJSCAA2ABJAJEJGZ1 (8P5B40-1R34/0)
    • Description: A DN40 model with 4-20mA HART output, display, and aluminum sensor housing. It features an ISO2852 clamp connection (DIN11866 series B) with a 0.38μm finish and includes a 3.1 material certificate. This is a standard configuration for biopharma 
  1. 8P5B25-AAIBAEAAFAABEABBKJWAA2DCEAEBJAJEJFZ1 (8P5B25-2A97/0)
  1. Description: A DN25 model equipped with 4-20mA HART plus a Pulse/Frequency output. It uses a DIN11864-2A flanged connection (aseptic flange) and features a stainless steel sensor connection housing. It includes enhanced diagnostics (Heartbeat Verification) 
  1. 8P5B15-********* (Customizable)**
    • Description: While the full code is variable, a typical 8P5B15 for WFI (Water for Injection) might feature the standard AAIB approvals/power/output stack, with a tri-clamp connection and a 0.38μm electropolish finish.
  1. 8P5B50-AAIB**G***** (Hygienic Heavyweight)**
    • Description: A DN50 model primarily used in downstream processing. Often specified with the stainless steel hygienic housing (position “G” as in the breakdown above) to withstand high-pressure washdowns.

Technical Specifications (At-a-Glance)

  • Measuring Principle: Coriolis (mass flow proportional to phase shift).
  • Measured Variables: Mass flow, Density, Temperature, Volume flow, Corrected volume flow, Concentration 
  • Maximum Measurement Error:
    • Mass Flow (liquid): ±0.10%
  • Density (liquid): ±0.0005 g/cm³
  • Medium Temperature Range: Standard –50 to +150°C (–58 to +302°F); Option up to +205°C (+401°F) 
  • Process Pressure: Up to PN 40, Class 150 
  • Materials (Wetted): 1.4435 (316L) stainless steel (low ferrite) 
  • Hygienic Approvals: 3-A, EHEDG, ASME BPE, cGMP compliant 
  • Degree of Protection: IP66/67 (standard), IP69 (with stainless steel sensor connection housing) 
  • Heartbeat Technology: Integrated self-diagnosis and verification for zero process interruption -3

Obtain relevant certificates and quotations for the product