pressure transmitter,temperature Transmitter,flow meter-ST-YK CLD

E&H 8S1C Coriolis Mass flowmeter

E&H 8S1C Coriolis mass flowmeter

Model:8S1C15-AADBAAASBKCWB+AA

Manufacturer: ENDRESS + HAUSER

Size: 100*100*100cm

Detail Specification: Coriolis mass flowmeter

Comment:Carton

Shipping Weight: 50Kg

Estimated Lead Time: 12 Weeks

Payment:T/T

HS CODE:9026201090

product details

E&H 8S1C Coriolis Mass flowmeter

Complete Technical Guide to ENDRESS + HAUSER 8S1C S100: Ultra-Compact Hygienic Coriolis Mass Flowmeter

In the demanding world of food, beverage, and pharmaceutical processing, the Endress+Hauser Proline Promass S 100 series (model 8S1C) represents the definitive solution for hygienic flow measurement. This ultra-compact Coriolis mass flowmeter features a self-drainable single-tube system combined with the smallest transmitter housing available today, delivering full functionality on the smallest footprint while meeting all hygiene requirements of the food and beverage industry . As a specialized supplier, ST-YUKE CO., LIMITED offers the full spectrum of the E&H 8S1C Coriolis mass flowmeter configurations to meet your exact hygienic application needs.

What is the E&H 8S1C Coriolis Mass Flowmeter?

The Promass 8S1C is an ultra-compact, sensor-dedicated Coriolis flowmeter from Endress+Hauser, belonging to the Promass S 100 family. Its defining feature is the hygienic design with a self-drainable single-tube system, specifically optimized for the food and beverage industry . Combined with an ultra-compact transmitter, it offers full functionality in space-constrained installations, making it the preferred choice for system integrators, skid builders, and equipment manufacturers . The measuring principle operates independently of physical fluid properties, ensuring accurate measurement unaffected by changing process conditions. It delivers multivariable measurement—capturing mass flow, density, and temperature simultaneously—with Heartbeat Technology for onboard verification and compliance .

E&H 8S1C Series Overview

The 8S1C series is categorized into five sensor sizes to cover a complete spectrum of hygienic flow applications from small-scale batching to full production lines :

E&H 8S1C08 (DN8): Designed for smaller flow rates in pilot plants, ingredient addition, and laboratory-scale production.

E&H 8S1C15 (DN15): Engineered for medium-flow applications requiring high accuracy in batching, blending, and filling processes.

E&H 8S1C25 (DN25): A versatile mid-range variant for general food and beverage production lines .

E&H 8S1C40 (DN40): Extended range for higher flow requirements in main production lines .

E&H 8S1C50 (DN50): Full-scale variant for maximum flow rates up to 70,000 kg/h in large-volume processing .

Technical Specifications at a Glance

To ensure the E&H 8S1C Coriolis mass flowmeter integrates perfectly into your hygienic process, here are the critical technical parameters based on the Promass S 100 series :

ParameterSpecification
Measurement PrincipleCoriolis (Self-drainable single-tube system)
Measured VariablesMass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Nominal Diameter RangeDN 8 to 50
Measuring Range0 to 70,000 kg/h (0 to 2570 lb/min)
Max. Measurement ErrorMass flow (liquid): ±0.10%
Volume flow (liquid): ±0.10%
Mass flow (gas): ±0.50%
Density (liquid): ±0.0005 g/cm³
Medium Temperature Range–50 to +150 °C (–58 to +302 °F)
Max. Process PressurePN 40, Class 150, 20K
Wetted MaterialsMeasuring tube: 1.4435 (316L); Connection: 1.4435 (316L); 1.4404 (316/316L)
Hygienic Compliance3-A and EHEDG conform; Designed for CIP/SIP cleaning with fast recovery
Transmitter HousingRobust, ultra-compact housing; High ingress protection: IP69K
Display/OperationOptional local display; Configuration via local display and operating tools
Outputs4-20 mA HART, pulse/frequency/switch output
Key TechnologyHeartbeat Technology for measurement reliability and compliant verification
ApplicationsFood & Beverage, Pharmaceutical, Hygienic processing, CIP/SIP systems

Model Code Breakdown: 8S1C15-AADBAAASBKCWB+AA

Understanding the E+H product structure is key to ordering the right unit for your hygienic application. Here is a technical breakdown of a specific configuration available through ST-YUKE CO., LIMITED:

Full Model: 8S1C15-AADBAAASBKCWB+AA

8S1C15: Base model (Promass S 100, hygienic design, DN15 sensor for medium-flow applications) .

A: Approval; Non-hazardous area (Standard certification for food/beverage plants).

A: Output; 4-20 mA HART with pulse/frequency/status output .

D: Display; Backlit display with touch control (integrated).

B: Housing; Compact, hygienic-grade aluminum coated.

A: Electrical connection; Gland M20 (standard).

A: Measuring tube material; 1.4435 (316L) stainless steel, hygienic finish .

A: Process connection; (Standard hygienic connection type – Tri-Clamp or DIN 11851).

S: Sensor version; Standard hygienic configuration.

B: Sensor option; Enhanced for specific hygienic applications.

K: Transmitter version; Standard configuration.

C: Transmitter output; Configured for HART protocol.

W: Power supply; Wide range AC (typically 100-240VAC).

B: Language; English manual.

+AA: Additional options; Basic accessory package including hygienic fittings certification.

*Note: This breakdown is based on standard E+H ordering structure conventions for the Promass S 100 series .*

Complete Ordering Examples: 8S1C Series Configurations

To illustrate the versatility of the Promass 8S1C series for hygienic applications, ST-YUKE CO., LIMITED supplies a wide range of models. Below is a selection of valid, complete model numbers to assist in your procurement process:

8S1C08-AADBBBLSBFNWA (8S1C08 for smaller flow rates, available as stock item)

8S1C15-AADBAAASBKCWB+AA (8S1C15 for medium-flow applications, backlit display, HART output, AC power, Tri-Clamp connection)

8S1C25-AADBAAASBKCWB+AA (8S1C25 mid-range variant, DN25, hygienic process connection)

8S1C40-AADBAAASBKCWB+AA (8S1C40 for higher flow requirements, hygienic design)

8S1C50-AADBAAASBKCWB+AA (8S1C50 full-scale variant, maximum flow up to 70,000 kg/h)

8S1C15-NADBAAASBKCWB+AK (8S1C15 with specific 3-A sanitary connections, ATEX/IECEx approval for hazardous areas)

8S1C25-AADBACASBKCWB+AA (8S1C25 with enhanced wetted parts finish for ultra-hygienic pharmaceutical applications)

8S1C40-AADBAAASBLCWB+AA (8S1C40 with pulse/frequency output configured for batching applications)

8S1C15-AADBAAASBKCWB+AKZ1 (8S1C15 with full Heartbeat Technology verification package and material certification 3.1 for FDA compliance)

8S1C25-AADBAAASBKCWB+LA (8S1C25 with SIL certification for safety-instrumented systems in critical processes)

Key Benefits for Hygienic Applications

The E&H 8S1C Coriolis mass flowmeter offers distinct advantages for food, beverage, and pharmaceutical processing :

Hygienic Design Excellence: Self-drainable single-tube system prevents product accumulation and enables thorough cleaning, meeting 3-A and EHEDG standards .

CIP/SIP Compatibility: Fast recovery from Clean-in-Place and Sterilize-in-Place cycles minimizes downtime between batches .

Space-Saving Installation: The ultra-compact transmitter housing delivers full functionality on the smallest footprint, ideal for skids and modular systems .

High Ingress Protection: IP69K rating ensures reliable operation during high-pressure washdown procedures .

Reduced Process Measuring Points: Multivariable measurement (flow, density, temperature) eliminates the need for additional instruments in hygienic processes .

Integrated Verification: Heartbeat Technology enables onboard diagnostics and compliance verification without process interruption .

Hygienic Process Connections

The 8S1C series supports a wide range of hygienic process connections to suit various industry standards :

Tri-Clamp (ISO 2852): Most common for food and beverage applications, easy to disassemble for cleaning

DIN 11851: Dairy standard connection with union nut

SMS 1145: Swedish dairy standard

DRD/Flanges: For aseptic applications requiring flush-mounted diaphragms

Varinline: For space-constrained installations with welded housings

Why Choose ST-YUKE CO., LIMITED for Your E+H 8S1C?

As a specialized supplier, we bridge the gap between complex German-Swiss engineering and your operational requirements. The E&H 8S1C Coriolis mass flowmeter represents the pinnacle of hygienic flow measurement with its ultra-compact, self-drainable design, making it ideal for food and beverage processing, pharmaceutical manufacturing, and CIP/SIP systems .

ST-YUKE CO., LIMITED provides:

Exact Configuration: Assistance in decoding the E+H product structure for the full 8S1C08/15/25/40/50 range.

Hygienic Compliance Expertise: Guidance on selecting the right process connections and certifications (3-A, EHEDG) for your regulatory requirements .

Application Engineering: Pre-sales and after-sales guidance on proper model selection for your specific flow range, viscosity, and cleaning protocols.

Genuine Supply Chain: Direct access to the full range of Promass S 100 models and configurations with competitive pricing and rapid delivery.

 

Obtain relevant certificates and quotations for the product

Scroll to Top

Send Us a Message