E&H 93TA1 ultrasonic flowmeter
Model:9B2B50-AAAACA1A121+AA
Manufacturer: ENDRESS + HAUSER
Size: 100*100*100cm
Detail Specification: ultrasonic flowmeter
Comment:Carton
Shipping Weight: 30Kg
Estimated Lead Time: 12 Weeks
Payment:T/T
HS CODE:9026809000
product details
E&H 93TA1 ultrasonic flowmeter
Product Introduction
The Proline Prosonic Flow 93T is Endress+Hauser‘s portable ultrasonic flow measurement solution designed for temporary monitoring and test measurements. Known by the order code 93TA1, this non-invasive flowmeter uses clamp-on sensors to measure liquid volume flow from outside the pipe, eliminating the need for process interruption-11.
Whether you are performing verification checks on existing flow metering points, conducting temporary monitoring across multiple measurement sites, or validating system performance during commissioning phases, the Prosonic Flow 93T delivers reliable, economical measurement with minimal setup time-3.
Key Features at a Glance
| Parameter | Value |
| Max. measurement error | ±2.0 % |
| Measuring range | 0 … 452,389 m³/h |
| Flow velocity range | 0 … 15 m/s |
| Nominal diameter range | DN 15 … 4000 (½” … 160”) |
| Max. process pressure | No limit |
| Degree of protection (transmitter) | IP40 |
| Degree of protection (sensors) | IP67 / IP68 |
| Display | Four-line backlit LCD with touch control |
| Data logging | Integrated USB data logging |
| Communication | FXA 193 |
| Analog outputs | 4 … 20 mA current output |
| Analog inputs | 4 … 20 mA current input |
Measuring Principle: Transit-Time Ultrasonic Technology
The Prosonic Flow 93T operates on the transit-time difference principle. Two ultrasonic transducers clamp onto the pipe exterior, alternately transmitting and receiving ultrasonic signals. When fluid flows, the signal traveling downstream moves faster than the signal traveling upstream. The flowmeter calculates the time difference between these two signals, then converts it into flow velocity and volumetric flow rate–.
This non-intrusive measurement method offers several inherent advantages:
No pressure loss — the clamp-on design introduces no flow obstruction
Bidirectional flow measurement capability
Unaffected by process pressure or fluid electrical conductivity
No moving parts, meaning virtually zero wear
Nominal Diameter Specifications
The 93TA1 accommodates an exceptionally wide pipe diameter range through three sensor families. Each sensor type is optimized for specific diameter bands and temperature conditions:
| Sensor Family | Nominal Diameter Range | Medium Temperature Range |
| U-Sensor | DN 15 … 65 (½” … 2½”) | –40 … +150°C (–40 … +302°F) |
| W-Sensor | DN 50 … 300 (2” … 12”) | –40 … +170°C (–40 … +338°F) |
| P-Sensor | DN 100 … 4000 (4” … 160”) | –40 … +80°C (–40 … +176°F) |
For the W-Sensor, an optional temperature variant is available for medium temperatures from 0 … +170°C (32 … +338°F)-3-7.
Measurement Performance
Accuracy
The Prosonic Flow 93T achieves a maximum measurement error of ±2.0 % of reading across its specified operating range-11.
Measurement Range
Volumetric flow rate: 0 … 452,389 m³/h (dependent on pipe diameter and fluid velocity)
Flow velocity: 0 … 15 m/s
This wide turndown capability allows the instrument to handle both low-flow and high-flow applications without requiring recalibration or sensor replacement.
Repeatability
The transit-time measurement method combined with automatic frequency scanning ensures consistent, repeatable results even when measurements are taken at different times or by different operators.
Operating Conditions
Medium Temperature
The 93TA1 handles a broad spectrum of fluid temperatures based on the sensor selected:
DN 15 … 65 sensors: –40 … +150°C (–40 … +302°F)
DN 50 … 300 sensors: –40 … +170°C (–40 … +338°F)
DN 100 … 4000 sensors: –40 … +80°C (–40 … +176°F)-11
Process Pressure
No upper pressure limit. Because the sensors are clamped externally onto the pipe wall, they never contact the process medium. This means the flowmeter can be used on high-pressure lines without derating or special pressure considerations-3-7.
Ambient Temperature
The portable transmitter is rated for field use in typical industrial environments. For extreme ambient conditions, consult the full technical documentation (TI00109D).
Fluid Compatibility
The Prosonic Flow 93T is suitable for any liquid that conducts ultrasonic waves. Typical applications include:
Water and wastewater
Demineralized water and drinking water
Cooling water and river water
Oils and hydrocarbons
Solvents and acids
Chemical reagents
Lightly contaminated liquids-3-7
The measurement is completely unaffected by the fluid‘s electrical conductivity, making the 93TA1 an excellent choice for deionized water applications where electromagnetic flowmeters would fail.
Pipe Compatibility
The 93TA1 works with virtually any pipe material capable of conducting ultrasonic waves:
Metal pipes (steel, stainless steel, copper, aluminum)
Plastic pipes (PVC, PP, PE)
Lined pipes
Composite pipes-3
For pipes with internal linings (e.g., rubber, PTFE, cement mortar), the ultrasonic signal penetrates the lining material as long as it is acoustically conductive. The installation requires only that the pipe surface is clean and that the sensors have solid acoustic contact.
Transmitter Specifications
Display and User Interface
The transmitter features a four-line backlit LCD that remains readable even in low-light field conditions. Navigation and parameter entry are handled via touch keys, providing a simple, glove-friendly interface-3.
The display shows:
Instantaneous flow rate (with selectable engineering units)
Totalized flow (forward/reverse/net)
Diagnostic messages
Sensor signal quality indicators
Power Supply
The 93TA1 operates independently of mains power using an internal rechargeable battery. A full charge typically supports a full day of intermittent measurements or several hours of continuous operation. The included power adapter recharges the battery when docked-11.
Protection Ratings
| Component | IP Rating | Description |
| Transmitter | IP40 | Protected against solid objects >1 mm; no water protection — suitable for indoor or sheltered outdoor use |
| Clamp-on sensors | IP67 / IP68 | Dust-tight and protected against temporary immersion; suitable for wet or submerged installation |
Physical Dimensions
Consult the Prosonic Flow 93T Technical Information document (TI00109D) for exact dimensional drawings.
Transmitter weight: Approximately 2.5 kg (5.5 lbs) including battery
Carrying case: Rugged, weather-resistant case included with standard configuration
Data Management and Connectivity
Integrated Data Logging
The Prosonic Flow 93T includes a built-in data logger capable of storing site configurations and measurement data. The instrument can retain up to 20 measuring site configurations, eliminating the need to re-enter parameters when moving between measurement points-3.
USB Data Transfer
Data transfer is accomplished via USB flash drive without requiring any additional software installation. Simply insert a standard USB stick, export the logged data, and analyze it on any PC-21.
Analog I/O
Current output: 4 … 20 mA (active/passive configurable) for integration with control systems, chart recorders, or remote displays
Current input: 4 … 20 mA for accepting external signals (e.g., pressure, temperature, or density) to enable calculated measurements such as mass flow or energy flow
Digital Communication
The instrument supports communication via FXA 193, Endress+Hauser‘s service interface for configuration and diagnostics using FieldCare or other asset management tools-3.
Installation and Mounting
Clamp-On Sensor Installation
The sensors mount directly onto the exterior pipe wall using specially designed mounting kits. The installation process requires no pipe cutting, welding, or process shutdown. A typical installation can be completed in minutes:
Clean the pipe surface at the intended mounting location
Apply acoustic couplant to the sensor faces
Secure the sensors using the appropriate mounting fixture (chain, strap, or rigid fixture)
Connect the sensor cables to the transmitter
Power on and verify signal strength
Mounting Configurations
The sensors can be installed in two configurations depending on pipe diameter and space constraints:
V-method (reflection mode): Single sensor pair, one reflection off the opposite pipe wall. Suitable for smaller diameters.
W-method (double reflection): Extended signal path for larger diameters or difficult acoustic conditions.
Z-method (through-transmission): Transmitting and receiving sensors mounted on opposite sides of the pipe. Recommended for large diameters, heavily scaled pipes, or when maximum signal strength is required.
Straight Run Requirements
For rated accuracy, the Prosonic Flow 93T requires straight pipe runs upstream and downstream of the sensor mounting location. Endress+Hauser‘s FlowDC technology helps maintain specified accuracy even in less-than-ideal piping configurations with as little as 2 × DN straight run-.
Application Examples
Verification of Existing Flow Meters
The primary intended use of the Prosonic Flow 93T is conducting verification measurements at already installed permanent flow metering points. By clamping onto the pipe alongside an existing meter, operators can:
Validate the permanent meter’s calibration
Detect drift or degradation in the installed instrument
Document measurement uncertainty for audit purposes
Temporary Monitoring
For applications requiring flow data for limited durations—such as pump performance testing, balancing HVAC systems, or troubleshooting flow issues—the 93TA1 provides a cost-effective solution that requires no permanent installation.
Multiple Measurement Points
The instrument‘s ability to store up to 20 site configurations makes it highly efficient for facilities that need to measure flow at many different locations. Operators can move from point to point, recall the saved configuration, and begin measuring immediately-3.
Order Code Information
The 93TA1 order code designates the portable Prosonic Flow 93T variant. Complete ordering codes follow the structure:
93TA1-XXXXXX+XXXXXX
Where the placeholder characters specify:
Sensor type and cable length
Transmitter configuration
Output options
Approvals and certifications
For example, 93TA1-CCAEAA+E2F1F2 represents a complete portable measurement system with standard configuration-.
Advantages and Benefits Summary
| Benefit | Description |
| No process interruption | Clamp-on installation means zero downtime |
| No pressure loss | Non-intrusive measurement adds no flow restriction |
| Bidirectional measurement | Measures flow in both forward and reverse directions |
| Battery-powered | Operates independently of external power supply |
| USB data transfer | No software installation required |
| Site memory | Stores up to 20 measurement point configurations |
| Wide pipe range | Covers DN 15 to 4000 (½” to 160”) |
| Wide fluid temperature range | Handles –40°C to +170°C (–40°F to +338°F) |
| Any conductive or non-conductive liquid | Unaffected by fluid conductivity |
| Diagnostic capability | Built-in process transparency and diagnostic functions |
| Automatic frequency scan | Optimizes measuring performance for each installation |
Limitations and Considerations
The following factors can affect measurement accuracy or feasibility:
Acoustic conductivity of the fluid: The fluid must be able to conduct ultrasonic waves. Heavily aerated or gas-entrained liquids, or those containing large suspended solids, may attenuate the signal.
Pipe wall condition: Heavily corroded, pitted, or scaled pipe surfaces can impede acoustic coupling.
Pipe liner adhesion: Liners that have separated from the pipe wall (debonded) will block the ultrasonic signal.
Transmitter protection: The IP40 rating of the transmitter requires protection from direct water spray or heavy rain.
Technical Documentation and Support
For complete engineering data, Endress+Hauser provides the following documentation for the Prosonic Flow 93T:
TI00109D/06/EN — Technical Information (full specifications, dimensions, and ordering details)
BA00109D/06/EN — Operating Instructions (installation, commissioning, and operation)
KA00109D/06/EN — Brief Operating Instructions (quick-start guide)