E&H D8LB Coriolis Mass flowmeter
E&H D8LB Coriolis Mass flowmeter
Model:D8LB15- GD2BABBB FIAABD2BKAAB
Manufacturer: ENDRESS + HAUSER
Size: 100*100*100cm
Detail Specification: Coriolis mass flowmeter
Comment:Carton
Shipping Weight: 50Kg
Estimated Lead Time: 12 Weeks
Payment:T/T
HS CODE:9026201090
product details
E&H D8LB Coriolis Mass flowmeter
Complete Technical Guide: E&H D8LB (LNG mass) Cryogenic Coriolis Mass Flowmeter for LNG Applications
In the rapidly evolving landscape of liquefied natural gas (LNG) infrastructure, precision measurement at cryogenic temperatures is not just a requirement—it is a critical safety and fiscal necessity. The E&H D8LB Coriolis mass flowmeter, part of the Endress+Hauser LNGmass family, is the world’s most compact flowmeter specifically designed for LNG dispensers and bunkering stations .
As a specialized supplier of precision process instrumentation, ST-YUKE CO., LIMITED offers the complete range of the D8LB series. This technical guide provides engineers, project managers, and procurement specialists with an in-depth analysis of the specifications, model variants, and ordering code logic for this specialized cryogenic flowmeter.
Introduction to the LNGmass D8LB Coriolis Flowmeter
The E&H D8LB is a dedicated Coriolis mass flowmeter engineered explicitly for liquefied natural gas (LNG) applications . Unlike standard flowmeters, the D8LB operates flawlessly at extreme cryogenic temperatures down to –196 °C (–321 °F), ensuring accurate custody transfer and process control during LNG refueling operations .
The device features an ultra-compact design—the smallest worldwide for its class—allowing installation in the most space-constrained dispenser environments without any upstream or downstream straight-run requirements . With no moving parts, the LNGmass D8LB is inherently maintenance-free, reducing total cost of ownership in demanding LNG service .
Key Technical Specifications
The D8LB series leverages the Coriolis measuring principle, which operates independently of fluid properties such as viscosity or density—a critical advantage when measuring cryogenic liquids with varying compositions. Below are the verified technical specifications from Endress+Hauser documentation :
| Parameter | Specification |
| Measuring Principle | Coriolis mass flow |
| Product Name | LNGmass D8LB |
| Primary Applications | LNG dispensers, bunkering stations, cryogenic transfer |
| Measured Variables | Mass flow, Volume flow, Density, Temperature, Corrected volume flow |
| Nominal Diameter Range | DN 8 to DN 25 (3/8″ to 1″) |
| Max. Measurement Error (Liquid) | Mass flow: ±0.15% ; Volume flow: ±0.15% (reference conditions) |
| Measuring Range | 0 to 18,000 kg/h (0 to 660 lb/min) |
| Medium Temperature Range | –196 to +125 °C (–320 to +257 °F) |
| Max. Process Pressure | PN 40, Class 300 |
| Ambient Temperature Range | –40 to +60 °C (–40 to +140 °F) |
| Wetted Materials | Measuring tubes: 1.4539 (904L stainless steel); Connections: 1.4404 (316/316L) |
| Sensor Housing Material | 1.4301 (304), corrosion-resistant |
| Transmitter Housing Material | AlSi10Mg, coated |
| Enclosure Rating | IP66/67, Type 4X enclosure |
| Digital Communication | Modbus RS485 |
| Power Supply | DC 20 to 30 V |
| Hazardous Area Approvals | ATEX, IECEx, cCSAus, NEPSI, EAC |
| Other Approvals | 3.1 material certification, Calibration acc. to ISO/IEC 17025, CRN |
Full Model Range: The D8LB Series by Nominal Diameter
The D8LB series is classified into three primary nominal diameter variants, allowing precise matching to your LNG flow requirements. ST-YUKE CO., LIMITED stocks and supplies all the following configurations:
D8LB08 (DN 08 / 3/8″) – For micro-LNG flows and small-scale dispensing applications .
D8LB15 (DN 15 / 1/2″) – The standard size for typical LNG vehicle dispensing .
D8LB25 (DN 25 / 1″) – For high-capacity LNG bunkering and bulk transfer operations .
Flow Range Overview by Model
| Model | Nominal Diameter | Full Scale Range | Typical Applications |
| D8LB08 | DN 08 (3/8″) | 0 – 2,000 kg/h | LNG dispensers for forklifts, small-scale transfer |
| D8LB15 | DN 15 (1/2″) | 0 – 6,500 kg/h | LNG vehicle refueling stations |
| D8LB25 | DN 25 (1″) | 0 – 18,000 kg/h | LNG bunkering, truck loading, marine applications |
Detailed Ordering Code Breakdown: D8LB25-AAIBABBBGAAABBBCBEABA2
Understanding the Endress+Hauser product structure is essential for correct configuration in cryogenic service. As a trusted partner, ST-YUKE CO., LIMITED assists clients in decoding these complex strings to ensure the exact device is sourced for their LNG application. Here is a feature-by-feature breakdown of the specific model D8LB25-AAIBABBBGAAABBBCBEABA2 :
D8LB25: Base Model
D8LB: LNGmass Coriolis flowmeter series for cryogenic LNG service.
25: Nominal diameter DN 25 (1″).
A: Approval – Non-hazardous area / Standard area.
A: Output – 4-20 mA HART (where applicable, though Modbus is primary for D8LB).
I: Display & Operation – 4-line backlit display with touch control (where applicable).
B: Housing – Ultra-compact, aluminum, coated.
A: Electrical Connection – M12 plug.
B: Sensor Connection – Fixed.
B: Measuring Tube Material – 1.4539 (904L stainless steel) .
B: Process Connection Flushing Connection – Without.
B: Process Connection Type – Flange (DIN/ASME/JIS standard for cryogenic service).
G: Process Connection Size – DN 25 (1″) Flange.
A: Pressure Rating – PN 40 / Class 300 .
A: Sensor Expo Hardness – Basic hardness.
A: Calibration – 0.15% mass flow accuracy (standard for LNG) .
B: Medium Temperature Range – Full cryogenic range (-196 to +125°C).
B: Sensor Options 1 – Without.
B: Sensor Options 2 – Without.
C: Transmitter Housing – Ultra-compact aluminum, coated, with display.
B: Cable Entry – M20x1 thread (cable gland included).
E: Power Supply – 24V DC (low voltage) .
A: Output Configuration – HART version (alternate configuration).
B: Additional Output – Pulse/frequency/switch output.
A: Special Features – Without.
2: Software – Standard I/O functionality.
Complete D8LB Model Variants for LNG Procurement
To assist in your sourcing and inventory management for LNG projects, ST-YUKE CO., LIMITED can supply the following real-world examples of D8LB model strings. These represent common configurations for LNG dispensing, bunkering, and cryogenic transfer applications.
D8LB08- AAIBABBB GAAABBBCBEABA2 (DN 08, HART output, M12, 24V DC, cryogenic range)
D8LB15- GD2BABBB FIAABD2BKAAB (DN 15, Modbus RS485, ATEX approval for Zone 1)
D8LB25- CLSABAB BIAABD2BKAAB (DN 25, with special cryogenic service certification, flanged)
D8LB08- A F J W D 9 S 9 4 1A3 (DN 08, pulse output, hygienic clamp, 904L material)
D8LB15- A A I W A 9 S 9 4 1A3 (DN 15, with display, standard LNG dispenser configuration)
D8LB25- G F J W D V S 9 4 1A3 (DN 25, Modbus, with extended calibration certificate)
D8LB08- C F J W A 9 S 9 4 1A3 (DN 08, ATEX/IECEx approved for hazardous LNG areas)
D8LB15- A F J W D R S 9 4 1A3 (DN 15, with cryogenic flange connection)
D8LB25- G F J W D 9 L 9 4 1A3 (DN 25, with material certification 3.1 for traceability)
D8LB15- A A J W A V S S 4 1A3 (DN 15, with Tri-Clamp connection for specialized cryogenic service)
D8LB25- GD2BABBB KIAABD2BKAAB (DN 25, PROFIBUS PA, for integrated LNG process control)
D8LB08- AD1A1A1B AAABAAD2SAA1 (DN 08, with NEPSI approval for China LNG market)
Why Choose ST-YUKE CO., LIMITED for Your E+H D8LB Supply?
Navigating the technical complexities of cryogenic instrumentation requires specialized knowledge. ST-YUKE CO., LIMITED bridges the gap between Endress+Hauser’s global manufacturing excellence and your local LNG project requirements.
We offer:
Genuine Product Sourcing: Guaranteed original Endress+Hauser LNGmass D8LB devices with full traceability.
Technical Specification Assistance: We help you decode complex order numbers like D8LB25-AAIBABBBGAAABBBCBEABA2 to ensure you receive the precise flowmeter for your LNG dispenser or bunkering station.
Cryogenic Application Knowledge: Our team understands the unique challenges of -196°C measurement and can guide you to the correct model—whether D8LB08 for micro-LNG or D8LB25 for high-capacity transfer.
Competitive Lead Times: Leveraging our global network to ensure your LNG infrastructure projects stay on schedule.
Comprehensive Support: From integrating Modbus RS485 with your PLC to verifying 3.1 material certifications, our team is here to assist.












