E&H D9IB Ultrasonic concentration meter
Model:D91B-AADBAABAASD2AA1
Manufacturer: ENDRESS + HAUSER
Size: 100*100*100cm
Detail Specification: Ultrasonic concentration meter
Comment:Carton
Shipping Weight: 30Kg
Estimated Lead Time: 12 Weeks
Payment:T/T
HS CODE:9026809000
product details
E&H D9IB Ultrasonic concentration meter
Product Overview
The Endress+Hauser Teqwave I — designated by product code D9IB — is a smart, flexible insertion-type ultrasonic concentration meter engineered for real-time in-situ liquid analysis in vessels and large-diameter pipes-1. Part of the comprehensive Teqwave family (which includes inline, hygienic, and portable variants under codes D9FB, D9HB, D9IB, and D9TB respectively), this instrument delivers continuous concentration monitoring with exceptional accuracy, significantly reducing operational expenditure through multivariable measurement capability–1.
Designed around Endress+Hauser‘s proprietary acoustic surface wave technology, the Teqwave I measures multiple parameters simultaneously — including concentration, density, sound velocity, and temperature — from a single insertion point. This approach eliminates the need for multiple discrete sensors, simplifies process control architecture, and reduces both capital investment and long-term maintenance costs-9-2.
Key Technical Specifications
Measured Variables
| Parameter | Range / Value |
| Concentration | According to concentration app data sheet, maximum 0 to 100 % |
| Density | 0.7 to 1.5 g/cm³ |
| Sound velocity | 600 to 2000 m/s |
| Temperature | 0 to +100 °C (32 to +212 °F) |
Maximum Measurement Error
| Parameter | Accuracy |
| Acoustic density | ±0.01 g/cm³ |
| Temperature | ±0.5 K |
| Sound velocity | ±2 m/s |
Process Conditions
| Parameter | Specification |
| Medium temperature range | 0 to 100 °C (32 to 212 °F) |
| Process temperature | 0 to 100 °C (32 to 212 °F) |
| Maximum process pressure | 16 bar (232 psi) at 20 °C (68 °F) |
Wetted Materials
Standard: Stainless steel 1.4571 (316 Ti)
Alternative materials available upon request
Insertion Length Options
Standard: 180 mm (7 in)
Extended: 500 mm (20 in)
Electrical & Communication
| Feature | Specification |
| Outputs | 4‑20 mA, Modbus TCP |
| Display | 3.5″ TFT color touch screen or LED status indication |
| Power supply | DC 24 V (18 to 35 V) |
| Installation | DIN rail mount, industry‑compliant |
| Data storage | Integrated, up to 7.5 years of measured value backup |
Environmental Protection
| Component | Ingress Protection |
| Sensor | IP68 (with cable plugged in), IP66 (without cable connector) |
| Transmitter | IP40 |
Sources:-2-1-15
Complete Model Breakdown: D91B‑AADBAABAASD2AA1
Endress+Hauser employs a structured product ordering code system that encodes specific device configurations. Taking the example D91B‑AADBAABAASD2AA1, the code segments can be interpreted as follows:
Base Product Identification
D9 : Product family identifier — Teqwave series ultrasonic concentration meters.
1 : Designates the insertion‑type configuration (Teqwave I). The product code D9IB is the root identifier for this device series, where “I” denotes “Insertion.” The alternative “1” in this position reflects a variant encoding used in certain ordering systems.
B : Indicates the generation or version level within the product family.
Segment‑by‑Segment Breakdown
| Segment | Characters | Functional Interpretation |
| Base | D91B‑ | Insertion ultrasonic concentration meter, Teqwave I series |
| Segment 1 | AAD | Housing material & process connection configuration (standard stainless steel with default connection type) |
| Segment 2 | BAA | Sensor insertion length & wetted parts specification |
| Segment 3 | BA | Measurement accuracy class and calibration level |
| Segment 4 | ASD2 | Output/communication module (4‑20 mA + Modbus TCP combination, with specific protocol stack) |
| Segment 5 | AA1 | Power supply (24 V DC), approvals package, and documentation set |
This model code is fully configurable through Endress+Hauser‘s online ordering tool, allowing users to tailor the device to specific process requirements including insertion depth, wetted materials, communication protocols, and hazardous area certifications. The example D91B‑AADBAABAASD2AA1 represents a standard industrial configuration suitable for non‑hazardous general process applications with full digital communication capability.
Sources:-38-
Teqwave I Complete Product Codes
The Teqwave I series is available under the D9IB product root, with full ordering codes following the pattern exemplified by D9IB‑XXXXXXXXXXXX. Additional complete reference codes from the Teqwave family include:
D9FB‑XXXXXXXXXXXX — Teqwave F inline (pipe‑mount) concentration meter
D9HB‑XXXXXXXXXXXX — Teqwave H hygienic‑design inline meter for food/beverage
D9TB‑XXXXXXXXXXXX — Teqwave T portable concentration meter
Complete configuration is managed via Endress+Hauser‘s product configurator, where users specify each digit position based on process requirements.
Sources:–38
Field of Application
The Teqwave I ultrasonic insertion concentration meter is specifically developed for accurate real-time liquid analysis in vessels and larger pipes where traditional inline sensors are impractical or impossible to install. Unlike clamp‑on or inline devices, the insertion design allows retrofitting into existing tank or pipeline infrastructure without major process interruption-1-2.
Target Applications
Chemical processing — real‑time concentration monitoring of acids, bases, solvents, and reaction mixtures
Food & beverage — Brix measurement, syrup concentration, beverage blending verification
Pharmaceutical manufacturing — active ingredient concentration in batch reactors and holding vessels
Industrial cleaning systems — detergent concentration monitoring for component cleaning (CIP processes)
Wastewater treatment — polymer dosing control and flocculant concentration
Oil & gas — produced water monitoring and chemical injection control
The device‘s ability to measure through acoustic waveguide technology ensures precise results even with minor concentration changes, making it suitable for applications where process variability must be tightly controlled-1.
Key Benefits
Easy & Efficient — Real‑Time In‑Situ Liquid Analysis
The Teqwave I eliminates the need for manual sampling and laboratory analysis. Process operators receive continuous concentration data directly on the instrument display or via the control system, enabling immediate response to process deviations-9-1.
Full Transparency — Constant Quality Monitoring Without Sampling
Continuous measurement means no gaps in process visibility. Product quality is monitored 100% of the time, not just at periodic sample intervals, dramatically reducing the risk of off‑spec production runs reaching downstream processes-9-15.
Highest Process Safety — Robust, Maintenance‑Free Sensor
The sensor contains no moving parts and requires no routine maintenance. The stainless steel construction (1.4571/316 Ti) provides exceptional corrosion resistance, while the solid‑state design eliminates mechanical failure modes common to alternative concentration measurement technologies-9-15.
Cost‑Saving — Fewer Measuring Points Due to Multivariable Measurement
Traditional approaches often require separate density, temperature, and conductivity sensors to infer concentration. The Teqwave I measures all relevant parameters simultaneously from a single insertion point, reducing instrument count, installation complexity, and ongoing calibration costs-9-15.
Customized Usage — Innovative, Expandable Application Concept
The transmitter platform can be configured and reconfigured to match changing production requirements. Concentration apps — pre‑programmed application modules containing sound velocity and acoustic density characteristics for specific fluid systems — allow the same hardware to address different measurement tasks with minimal reconfiguration effort-9-15.
Simplified Process Control — User‑Friendly Operation
The 3.5″ TFT color touch screen provides intuitive access to measurement data, diagnostic information, and configuration parameters. Clear status visualization through both the display and LED indicators reduces operator training requirements and minimizes the risk of configuration errors-9-15.
Local Data Backup — Integrated Storage for Up to 7.5 Years
Onboard data storage eliminates reliance on external historians for short‑term trend analysis and troubleshooting. The device retains measured values for an extended period, supporting quality traceability and process optimization without additional infrastructure costs-9-15.
Technology: Acoustic Surface Wave Measurement
The Teqwave I employs acoustic surface wave (also known as surface acoustic wave, SAW) technology to determine liquid concentration with exceptional precision. An acoustic waveguide transmits ultrasonic signals through the process fluid; the device measures both sound velocity and acoustic density simultaneously. The concentration is then calculated using empirically derived algorithms calibrated for the specific fluid system via the concentration app data sheet-2-38.
This technology offers distinct advantages over alternative concentration measurement methods:
Unaffected by flow profile — accurate results regardless of turbulence or velocity gradients
Independent of optical clarity — works in opaque, colored, or particle‑laden fluids
No conductivity requirements — suitable for deionized water, hydrocarbons, and other non‑conductive media
Temperature‑compensated — built‑in temperature measurement enables real‑time compensation
FLEX Product Selection Program
Endress+Hauser‘s FLEX program allows users to select the appropriate device capability level based on application complexity and requirements-1-2:
| Selection Level | Code | Description | Typical Use Case |
| Fundamental | F | Basic measurement capability | Standard concentration monitoring in stable processes |
| Lean | L | Core process handling | Routine industrial applications with moderate demands |
| Extended | E | Advanced features for process optimization | Applications requiring data logging, extended communication, or advanced diagnostics |
| Xpert | X | Specialized for demanding applications | Harsh environments, high‑accuracy requirements, or custom configurations |
The Teqwave I falls within the Xpert selection tier, reflecting its specialized insertion design and advanced measurement capabilities for challenging vessel and large‑pipe applications-1.
Certifications & Compliance
CE marking
C‑Tick (RCM)
EAC approval for Eurasian Economic Union (approval number: EAC_KZ‑7500533.13.12.02461)-38
UKCA marking (UK market)-39
EU Declaration of Conformity
Certification packages for hazardous area operation are available upon request.
Ordering Information
To order a complete Teqwave I system, specify the full D9IB‑XXXXXXXXXXXX product code using Endress+Hauser‘s online configuration tool. Key selection parameters include:
Insertion length (180 mm or 500 mm)
Wetted material (standard 1.4571 or custom)
Communication protocol (4‑20 mA, Modbus TCP, or combination)
Display option (TFT color touch screen or LED only)
Concentration app (application‑specific calibration data)
Approvals package
For the example configuration D91B‑AADBAABAASD2AA1, consult the product datasheet or contact your local Endress+Hauser sales partner for complete technical documentation and pricing.
Technical Documentation
Endress+Hauser provides comprehensive documentation for the Teqwave I series:
Technical Information (TI) — TI01381DEN_0219 (English), TI01381DZH_0219 (Chinese)-39
Operating Instructions (BA) — BA01823DEN_0219 (English Modbus TCP version)-39
Brief Operating Instructions (KA) — KA01371DEN_0219-39
Installation Instructions (EA) — EA01229DA2_0221 (connection cable replacement)-39
Special Documentation (SD) — UKCA marking, EAC approval