E&H DTI electromagnetic flowmeter
E&H DTI electromagnetic flowmeter
| MODEL:DTI200-A11A1A+1 Manufacturer: ENDRESS + HAUSER Size: 100*100*100cm Detail Specification: electromagnetic flowmeter Comment:Carton Shipping Weight: 50Kg Estimated Lead Time: 12 Weeks Payment:T/T HS CODE:9026201090
|
product details
E&H DTI electromagnetic flowmeter
The Complete Technical Guide to the E&H DTI200 Electromagnetic Flowmeter: Cost-Effective Insertion Flow Monitoring for Water Utilities
In the demanding fields of water distribution, wastewater treatment, and industrial utilities, reliable flow monitoring with minimal investment is essential. The E&H DTI200 electromagnetic flowmeter, also known as the Magphant series, stands as the cost-effective, compact solution for insertion flow measurement and monitoring in conductive liquids -1. Engineered for simplicity and reliability, the DTI200 series delivers repeatable flow information with a space-saving design that installs directly into existing pipelines -6.
As a trusted supplier, ST-YUKE CO., LIMITED offers a comprehensive range of the E&H DTI200 electromagnetic flowmeter configurations. Whether you require installation in steel pipes as small as DN25 or plastic pipes down to DN15, understanding the technical nuances of this device is crucial for optimal process integration -1. This guide provides an in-depth look at the technical parameters, model breakdown, and ordering code for the versatile E&H DTI200 series.
Key Technical Specifications of the E&H DTI200 Series
The E&H DTI200 electromagnetic flowmeter is engineered for bidirectional measurement of liquids with a minimum conductivity of ≥5 μS/cm. Its insertion design allows for easy retrofitting into existing pipelines without process interruption, and the operation is virtually independent of pressure, density, temperature, and viscosity -7-10.
| Parameter | Specification |
| Measuring Principle | Electromagnetic induction (Insertion type) -9 |
| Primary Applications | Water distribution, wastewater monitoring, utility flow management, pump protection, leak detection -7-10 |
| Nominal Diameter Range | DN 15 to DN 2000 (½ to 80 inches) for plastic pipes; DN 25 to DN 2000 (1 to 80 inches) for steel pipes -1-9 |
| Measuring Range | 0 to 56,550 m³/h (0 to 332,800 gal/min) -7-9-10 |
| Maximum Measurement Error | 2% o.r. -7-9-10 |
| Medium Temperature Range | -20 to +120°C (-4 to +248°F) -7-9-10 |
| Maximum Process Pressure | 0 to 16 bar abs (0 to 232 psi) -7-9-10 |
| Minimum Conductivity | ≥5 μS/cm for conductive liquids |
| Wetted Materials | 1.4435 (316L) stainless steel electrodes; Process connection materials: ST.37/A570 steel, stainless steel, NBR gaskets -2-7 |
| Outputs & Communication | 4-20 mA analog output; Relay output with adjustable switch points -1-6-9 |
| Enclosure Ratings | IP66 / NEMA 4X / Type 4X -9 |
| Display & Operation | Rotary switch for switch point setting; Potentiometer for full-scale adjustment; Test function for electronics verification -6-8-9 |
| Power Supply | 24 V DC (20…30 V DC) -9 |
| Key Features | Self-monitoring with empty pipe detection (4 mA output); Integrated test function for electronics; No moving parts – maintenance free; No pressure loss due to cross-section constriction -1-6-9 |
| Certifications | ATEX, FM, CSA for hazardous areas; CE, EAC for product safety -7-9 |
Comprehensive E&H DTI200 Model Variants
The versatility of the E&H DTI200 electromagnetic flowmeter is reflected in its range of model numbers, which denote specific configurations for various pipeline sizes and connection requirements. Below is a list of common variants available through ST-YUKE CO., LIMITED, covering a wide spectrum of water applications.
| Configuration Type | E&H DTI200 Model Numbers |
| Basic Configurations | DTI200-A11A1A, DTI200-A25B1A -2-5 |
| Plastic Pipe Versions | DTI200-A25B1A (DN 15-1000 / ½-40″ plastic) -5 |
| Steel Pipe Versions | DTI200-A11A1A (DN 25-2000 / 1-80″ steel) -2 |
| Hazardous Area Versions | DTI200 models with ATEX/FM/CSA certification -7 |
Additional configurations may include variations in cable entries (M20, PG16), process connections (union nut, weld-on nipple, adapter), and approval types -2-5.
Decoding the E&H DTI200 Ordering Code: A Detailed Example
To illustrate the configurability of the E&H DTI200 electromagnetic flowmeter, let us break down a specific product code: DTI200-A11A1A+1 .
Position 1-6: The Base Model
DTI200: This identifies the device as a Magphant insertion electromagnetic flowmeter -1-6. This series is specifically designed for cost-effective flow monitoring in water and utility applications.
Position 7-8: Pipe Diameter Range
A1: This specifies the applicable pipe diameter range.
A1: Suitable for steel pipes with nominal diameter DN 25 to 2000 (1 to 80 inches) . This covers the vast majority of industrial and municipal pipeline applications -2.
Position 9-10: Process Connection / Material
1A: This section details the process connection and materials.
1: Indicates the connection type—typically a union nut with weld-on nipple for secure installation into the pipeline.
A: Specifies the materials of construction. For this configuration, it includes ST.37 / A570 steel for the nipple and compression ferrule with NBR gasket to ensure a leak-resistant seal -2.
Position 11-12: Cable Entry / Approvals
A1: These positions cover electrical connections and certifications.
A: Specifies the cable entry type, likely PG16 cable glands as standard -2.
1: Indicates the approval type. “1” typically signifies certification for non-hazardous areas, suitable for general water and utility applications -5.
Position 13-14: Accessories (Separated by +)
+1: This suffix indicates additional accessories or services. In this context, it may denote standard documentation or basic configuration options.
Why Choose ST-YUKE CO., LIMITED for Your E&H DTI200?
Selecting the right configuration of an E&H DTI200 electromagnetic flowmeter requires understanding of both the application requirements and installation conditions. At ST-YUKE CO., LIMITED, we specialize in helping clients navigate the DTI200 series—from compact installations in DN25 plastic pipes to large-scale monitoring in DN2000 steel pipelines.
Our team ensures you receive the exact device for your application, configured with the correct process connections, materials, and approvals required by your facility. We understand the critical importance of:
Cost-Effective Monitoring: The DTI200 provides reliable flow information at a fraction of the cost of full-bore magmeters -9
Easy Retrofit Installation: Insertion design allows installation into existing pipelines without cutting the pipe or interrupting flow -3
Reliable Operation: Self-monitoring with empty pipe detection and integrated electronics testing ensures process safety -1-6
Simple Configuration: Rotary switch for switch point setting and potentiometer for full-scale adjustment enable quick on-site setup without special tools -8-9
Versatile Application: Suitable for both steel and plastic pipes across a wide diameter range -1
By choosing ST-YUKE CO., LIMITED, you benefit from:
Technical Expertise: Guidance on selecting the correct model for your specific pipe material, diameter, and application requirements
Genuine Products: Assurance of authentic Endress+Hauser devices with full certifications and quality guarantees
Global Logistics: Efficient shipping to project sites worldwide, including support for water utility and industrial projects
Application Support: Assistance with installation planning, configuration, and integration into existing monitoring systems