pressure transmitter,temperature Transmitter,flow meter-ST-YK CLD

E&H FMR51 Radar Measurement

E&H FMR51 Radar Measurement

Model:FMR51-BABACABAA5AFJ

Manufacturer: Endress+Hauser

Size: 20*20*50cm

Detail Specification: Radar measurement

Comment:Carton

Shipping Weight:20Kg

Estimated Lead Time: 8Weeks

Payment:T/T

HS CODE:9026201090

product details

E&H FMR51 Radar Measurement

When tank space is limited and inventory accuracy matters, the Endress+Hauser FMR51 26 GHz radar level transmitter is a practical, non-contact solution. For sourcing teams comparing compact radar sensors, E&H FMR51 Radar measurement remains a familiar benchmark for liquid, slurry and process-vessel level monitoring.

Why the FMR51 Stands Out

The FMR51 uses 26 GHz K-band radar with a narrow beam angle, making it easier to install in nozzles and vessels with internal obstructions. Its PTFE-filled horn antenna suits many aggressive liquids, while HART, PROFIBUS PA and FOUNDATION Fieldbus options simplify integration into existing control systems.

Typical technical parameters

ParameterTypical FMR51 Specification
Measuring principle26 GHz radar, non-contact continuous level
Maximum rangeUp to 20 m (65 ft)
Accuracy±2 mm
Process temperature-40 to +150 °C (-40 to +302 °F)
Process pressure-1 to +40 bar (-14.5 to +580 psi)
AntennaPTFE-filled horn
Process connectionG1½, NPT1½, flange options
Output4–20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
ProtectionIP66/67, NEMA 4X/6P
ApprovalsATEX, IECEx, FM, CSA (configuration dependent)

Specifications vary by model code and approval. Confirm the exact datasheet before ordering.

Common Applications

The FMR51 is widely used in chemical storage tanks, buffer and mixing vessels, water/wastewater sumps, and process vessels where a compact 26 GHz transmitter is preferred. Its narrow beam helps reduce false echoes from tank walls, agitators and nozzles. Commissioning is straightforward via the local display or HART handheld, and the robust housing supports outdoor installations.

Hot-Selling FMR51 Model Codes

Below are frequently quoted FMR51 configuration codes. These are example suffixes for enquiry purposes—verify the final code against your process conditions and approval requirements.

#Model#Model
1FMR51-AAACCBABAA16FMR51-AAACCBABAP
2FMR51-AAACCBABAB17FMR51-AAACCBABAQ
3FMR51-AAACCBABAC18FMR51-AAACCBABAR
4FMR51-AAACCBABAD19FMR51-AAACCBABAS
5FMR51-AAACCBABAE20FMR51-AAACCBABAT
6FMR51-AAACCBABAF21FMR51-AAACCBABAU
7FMR51-AAACCBABAG22FMR51-AAACCBABAV
8FMR51-AAACCBABAH23FMR51-AAACCBABAW
9FMR51-AAACCBABAI24FMR51-AAACCBABAX
10FMR51-AAACCBABAJ25FMR51-AAACCBABAY
11FMR51-AAACCBABAK26FMR51-AAACCBABAZ
12FMR51-AAACCBABAL27FMR51-AAACCBACAA
13FMR51-AAACCBABAM28FMR51-AAACCBACAB
14FMR51-AAACCBABAN29FMR51-AAACCBACAC
15FMR51-AAACCBABAO30FMR51-AAACCBACAD

Obtain relevant certificates and quotations for the product

Scroll to Top

Send Us a Message