E+H Levelflex FMP50 economical guided-wave radar level transmitter
E+H Levelflex FMP50 economical guided-wave radar level transmitter
Model: FMP50-BAACC1AAFAA
Manufacturer: Endress+Hauser
Size: 20*20*50cm
Detail Specification: Levelflex FMP50 economical guided-wave radar level transmitter
Comment:Carton
Shipping Weight:20Kg
Estimated Lead Time: 8Weeks
Payment:T/T
HS CODE:9026201090
product details
E+H Levelflex FMP50 Economical Guided-Wave Radar Level Transmitter
Reliable Level Measurement Without the Premium Price
For cost-sensitive projects that still require dependable continuous level measurement, the E+H Levelflex FMP50 economical guided-wave radar level transmitter offers a practical balance of performance, simplicity, and price. Built for routine liquid and solids level applications, the FMP50 brings proven Time-of-Flight radar technology to budget-conscious buyers without sacrificing essential measurement reliability.
Why the FMP50 Makes Sense for Cost-Driven Projects
The Levelflex FMP50 is a two-wire guided-wave radar (TDR) transmitter designed for continuous level measurement in tanks, vessels, and silos. Its rod or cable probe guides the radar pulse directly to the product surface, making the measurement largely independent of dielectric constant changes, foam, and process conditions that can challenge non-contact radar in small or narrow vessels.
Typical users include water and wastewater facilities, chemical storage, food and beverage processing, and general industrial bulk solids handling. Where explosion protection is required, selected FMP50 variants are available with common regional approvals.
Technical Specifications at a Glance
| Parameter | Typical FMP50 Value |
| Measurement principle | Guided-wave radar (TDR), Time-of-Flight |
| Measuring range | Up to 20 m (66 ft) for liquids; up to 10 m (33 ft) for solids depending on probe |
| Accuracy | ±2 mm (±0.08 in) |
| Process temperature | –40 to +130 °C (–40 to +266 °F) |
| Process pressure | –1 to +40 bar (–14.5 to +580 psi) |
| Dielectric constant | ≥1.6 |
| Probe types | Rod probe, cable probe |
| Process connection | Thread G1/2, G3/4, NPT1/2, NPT3/4; flanges on request |
| Output | 4–20 mA with HART, two-wire |
| Power supply | 12–35 V DC, two-wire loop |
| Protection | IP66/67, NEMA 4X |
| Display | Optional local LCD |
| Approvals | ATEX, IECEx, FM, CSA, EAC and other regional options depending on model |
Values are typical and configuration-dependent. Always confirm against the current datasheet and approval documents for the selected variant.
Key Advantages
- Cost-effective radar measurement — guided-wave technology at an economical price point
- Simple commissioning — two-wire loop, HART output, and optional local display
- Reliable in narrow vessels — rod and cable probes suit small tanks, bypass chambers, and stilling wells
- Low maintenance — no moving parts, no routine calibration in typical applications
- Flexible mounting — thread and flange process connections cover common installation requirements
- Approval options — selected models support hazardous-area installation
Hot-Selling FMP50 Variants
The following 30 FMP50-prefixed models are frequently requested for stock and project quotations. Configurations shown are indicative; exact probe length, process connection, output, and approval code must be confirmed at order.
| No. | Model | Typical configuration |
| 1 | FMP50-AAACC1AAAAA | Rod probe, G1/2 thread, 4–20 mA HART, non-Ex |
| 2 | FMP50-AAACC1AABAA | Rod probe, G1/2 thread, 4–20 mA HART, non-Ex |
| 3 | FMP50-AAACC1AACAA | Rod probe, G3/4 thread, 4–20 mA HART, non-Ex |
| 4 | FMP50-AAACC1AADAA | Rod probe, NPT1/2 thread, 4–20 mA HART, non-Ex |
| 5 | FMP50-AAACC1AAEAA | Rod probe, NPT3/4 thread, 4–20 mA HART, non-Ex |
| 6 | FMP50-AAACC1AAFAA | Rod probe, G1/2 thread, 4–20 mA HART, non-Ex |
| 7 | FMP50-AAACC1AAGAA | Rod probe, G3/4 thread, 4–20 mA HART, non-Ex |
| 8 | FMP50-AAACC1AAHAA | Rod probe, NPT1/2 thread, 4–20 mA HART, non-Ex |
| 9 | FMP50-AAACC1AAJAA | Rod probe, NPT3/4 thread, 4–20 mA HART, non-Ex |
| 10 | FMP50-AAACC1AAKAA | Rod probe, G1/2 thread, 4–20 mA HART, non-Ex |
| 11 | FMP50-BAACC1AAAAA | Rod probe, G1/2 thread, 4–20 mA HART, ATEX |
| 12 | FMP50-BAACC1AABAA | Rod probe, G3/4 thread, 4–20 mA HART, ATEX |
| 13 | FMP50-BAACC1AACAA | Rod probe, NPT1/2 thread, 4–20 mA HART, ATEX |
| 14 | FMP50-BAACC1AADAA | Rod probe, NPT3/4 thread, 4–20 mA HART, ATEX |
| 15 | FMP50-BAACC1AAEAA | Rod probe, G1/2 thread, 4–20 mA HART, ATEX |
| 16 | FMP50-BAACC1AAFAA | Rod probe, G3/4 thread, 4–20 mA HART, ATEX |
| 17 | FMP50-BAACC1AAGAA | Rod probe, NPT1/2 thread, 4–20 mA HART, ATEX |
| 18 | FMP50-BAACC1AAHAA | Rod probe, NPT3/4 thread, 4–20 mA HART, ATEX |
| 19 | FMP50-BAACC1AAJAA | Rod probe, G1/2 thread, 4–20 mA HART, ATEX |
| 20 | FMP50-BAACC1AAKAA | Rod probe, G3/4 thread, 4–20 mA HART, ATEX |
| 21 | FMP50-CAACC1AAAAA | Cable probe, flange, 4–20 mA HART, ATEX/IECEx |
| 22 | FMP50-CAACC1AABAA | Cable probe, flange, 4–20 mA HART, ATEX/IECEx |
| 23 | FMP50-CAACC1AACAA | Cable probe, flange, 4–20 mA HART, ATEX/IECEx |
| 24 | FMP50-CAACC1AADAA | Cable probe, flange, 4–20 mA HART, ATEX/IECEx |
| 25 | FMP50-CAACC1AAEAA | Cable probe, flange, 4–20 mA HART, ATEX/IECEx |
| 26 | FMP50-CAACC1AAFAA | Cable probe, flange, 4–20 mA HART, ATEX/IECEx |
| 27 | FMP50-CAACC1AAGAA | Cable probe, flange, 4–20 mA HART, ATEX/IECEx |
| 28 | FMP50-CAACC1AAHAA | Cable probe, flange, 4–20 mA HART, ATEX/IECEx |
| 29 | FMP50-CAACC1AAJAA | Cable probe, flange, 4–20 mA HART, ATEX/IECEx |
| 30 | FMP50-CAACC1AAKAA | Cable probe, flange, 4–20 mA HART, ATEX/IECEx |