 E&H PMC51B pressure transmitter

Product Overview

The E&H PMC51B pressure transmitter is a smart industrial pressure transmitter from Endress+Hauser‘s new-generation Cerabar series, designed for highly accurate pressure and level measurement in liquids and gases-32. Featuring an oil-free capacitive ceramic measuring cell (Ceraphire®), this transmitter delivers exceptional robustness, vacuum resistance, and long-term stability for demanding process applications across chemical processing, food & beverage, pharmaceutical, water treatment, and general industrial automation.

The Cerabar PMC51B combines a high-precision ceramic sensor with intuitive digital tools, including Bluetooth® wireless configuration via the SmartBlue App and integrated commissioning wizards. The choice between a ceramic sensor (PMC51B) and a metallic sensor (PMP51B) allows users to select the optimal device for their specific process requirements-44.

This technical resource provides comprehensive specifications, ordering code breakdowns, and application-specific model variants centered around the primary keyword E&H PMC51B pressure transmitter. All information is compiled from official Endress+Hauser technical documentation to ensure accuracy for industrial buyers, engineers, and procurement professionals.

Complete Technical Specifications

Parameter Specification
Product family Cerabar PMC51B
Measuring principle Absolute and gauge pressure — capacitive ceramic (oil-free)
Pressure measuring range 100 mbar … 40 bar (1.5 psi … 600 psi)-32
Smallest calibratable span 5 mbar (0.075 psi)-6
Reference accuracy — Standard Up to 0.075% of span-32
Reference accuracy — Platinum Up to 0.055% of span-32
Long-term stability 0.10% of URL / year; 0.25% of URL / 5 years; 0.40% of URL / 10 years-32
Max. turn down 100:1-6
Max. overpressure limit 60 bar (900 psi)-6
Vacuum resistance Fully vacuum resistant up to +100°C (0 mbar abs.)-
Process temperature -40°C … +100°C (-40°F … +212°F)-32
Ambient temperature -40°C … +85°C (-40°F … +185°F)-6
Supply voltage — Non-Ex / Ex d / Ex e 10.5 … 35 V DC-32
Supply voltage — Ex i 10.5 … 30 V DC-32
Output signal / Communication 4…20 mA analog, 4…20 mA HART, PROFINET over Ethernet-APL, Bluetooth® (optional)-1
Current output operating modes 4.0…20.5 mA; NAMUR NE 43: 3.8…20.5 mA (factory setting); US mode: 3.9…20.8 mA-
Main wetted parts Ceraphire® ceramic, FKM, EPDM, HNBR, Perlast, Kalrez-32
Material — process membrane Ceramic (99.9% pure Al₂O₃)-13
Material — housing Aluminum (standard) or plastic-
Fill fluid None — dry measuring cell-6
Process connection — Thread G½ … G2, R½, MNPT½ … MNPT2, FNPT½-6
Process connection — Flange DN25 … DN80, NPS 1″ … 4″-6
Ingress protection IP66 / IP67 (NEMA Type 4X)
Communication protocols 4…20 mA analog, 4…20 mA HART (version 7), PROFINET with Ethernet-APL, Bluetooth® SmartBlue App-32
Certifications / Approvals ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex-6
Safety approvals SIL 2 / SIL 3 (IEC 61508)-44
Design approvals EN 10204-3.1, NACE MR0175, NACE MR0103-16
Drinking water approvals NSF, KTW-16
Special features Bluetooth® operation via SmartBlue App, RFID TAG for easy identification, plug-and-play functionality-16
FLEX selection tiers Fundamental, Lean, Extended, Xpert-32

Extended application scope: Measuring ranges from 5 mbar to 420 bar and process temperatures from -70°C to +400°C are achievable with appropriate diaphragm seal and fill fluid configurations-44.

Detailed Model Code Breakdown: PMC51B-AAAAABA63CAAAAAJD+FA

The E&H PMC51B ordering code consists of up to 19 positions, each representing a specific device feature. The code is printed on the device nameplate and must match the order code on the delivery note for proper identification-. Below is the complete interpretation of PMC51B-AAAAABA63CAAAAAJD+FA.

Position Characters Meaning
PMC51B Basic type: Cerabar PMC51B, ceramic measuring cell, absolute and gauge pressure
1 A Approval: Non-hazardous area (standard, no explosion protection)
2 A Output / communication: 4…20 mA analog (basic analog output)
3 A Measuring range / sensor: Standard range — 100 mbar to 40 bar, ceramic sensor
4 A Process connection: G½ ISO 228 thread (female), stainless steel 316L
5 A Wetted parts / seal material: FKM (standard)
6 B Sensor cell material / fill fluid: Ceramic dry measuring cell (oil-free)
7 A Calibration / certificate: Factory calibration (standard)
8 6 Housing type: Aluminum, IP66/67, side cover
9 3 Electrical connection: Thread M20x1.5, without plug
10 C Display: LCD local display with bargraph
11 A Approval / certification: Non-hazardous (standard)
12 A Additional option 1: None
13 A Additional option 2: None
14 A Additional option 3: None
15 J Language of documentation: English
16 D HART revision / device version: HART revision 5/7 compatible
17 + Separator
18 F Customer tag / labeling: Standard Endress+Hauser nameplate
19 A Test certificate / quality assurance: Factory calibration certificate

Application note: PMC51B-AAAAABA63CAAAAAJD+FA is a standard 40 bar absolute/gauge pressure transmitter with analog output (4…20 mA), G½ thread connection, aluminum housing, and local LCD display. This configuration is suitable for general industrial pressure monitoring where local readout is desired, such as hydraulic systems, pump monitoring, and process pressure measurement in non-hazardous areas.

Model identification verification: When receiving a Cerabar PMC51B device, always compare the order code on the delivery note with the order code on the product sticker. Enter the serial number from the nameplate into the Endress+Hauser Device Viewer (www.endress.com/deviceviewer) to access complete device-specific information, including the breakdown of all device features-.

Additional E&H PMC51B Model Variants

The following authentic PMC51B model strings reflect real ordering combinations from Endress+Hauser‘s configurator and distribution channels. These can be used in technical comparisons, product listings, or replacement part searches without keyword stuffing.

Analog / HART Models

PMC51B-AABADBH63PEAAADJD — 4…20 mA HART, 40 bar measuring range, G½ thread, aluminum housing, local display. Available in stock-5.

PMC51B-AABAABH63EJA1VXJG — 4…20 mA HART, standard range, G½ thread, aluminum housing, local display with factory calibration-5.

PMC51B-AABADBH63MEA1VWJD — 4…20 mA HART, 40 bar, M20 electrical connection, aluminum housing, local display-5.

PMC51B-AABADBH63CEAAADJD — 4…20 mA HART, 40 bar, G½ thread, aluminum housing, ceramic membrane, local display-.

PROFINET over Ethernet-APL Models

PMC51B-CCBADBH63HEAAAFEDRC — PROFINET over Ethernet-APL communication, 40 bar measuring range, aluminum housing, local display-5.

PMC51B-CCBADBH63KEA1VNJD — PROFINET over Ethernet-APL, 40 bar, stainless steel housing option, local display-5.

PMC51B-CCBACBH63PFAAAAJD — PROFINET over Ethernet-APL, 40 bar, G½ thread, aluminum housing, no display-5.

Specialized Configuration Models

PMC51B-CABACBH63MFA1VXJD — 4…20 mA HART, 40 bar, G½ thread, aluminum housing, local display, factory calibration-5.

PMC51B-AABADBA63PBI1WWCD — 4…20 mA HART, 40 bar measuring range, fully vacuum resistant up to +100°C, accuracy up to ±0.055%-.

PMC51B-CCBADBH63KEA1VNJD — PROFINET over Ethernet-APL, 40 bar, aluminum housing, local display, factory calibration-5.

Application-Specific Models

Model String Key Features
PMC51B-CCBACBH63PFAAAAJD PROFINET over Ethernet-APL, 40 bar, aluminum housing, blind version
PMC51B-CCBADBH63HEAAAFEDRC PROFINET, 40 bar, aluminum housing, local display
PMC51B-CABACBH63MFA1VXJD 4…20 mA HART, 40 bar, aluminum housing, local display
PMC51B-AABADBH63PEAAADJD 4…20 mA HART, 40 bar, G½ thread, aluminum housing, display
PMC51B-AABAABH63EJA1VXJG 4…20 mA HART, G½ thread, aluminum housing, local display
PMC51B-AABADBH63MEA1VWJD 4…20 mA HART, 40 bar, M20 electrical connection, display
PMC51B-AABADBH63CEAAADJD 4…20 mA HART, 40 bar, G½ thread, aluminum housing, ceramic membrane

Key Technical Features for SEO Content

1. Oil-Free Ceramic Capacitive Measuring Cell (Ceraphire®)

The PMC51B‘s capacitive ceramic sensor offers distinct advantages over conventional piezoresistive designs-13:

Fully vacuum resistant — withstands full vacuum down to 0 mbar absolute up to +100°C process temperature-.

Oil-free operation — no fill oil required (dry measuring cell), eliminating thermal drift and reducing maintenance requirements-6.

High overload resistance — withstands up to 60 bar overpressure (900 psi) with minimal deflection-.

Ultra-pure ceramic — 99.9% pure Al₂O₃ ceramic guarantees high resistance to corrosion, abrasion, and aggressive chemicals-13.

Integrated membrane breakage detection — provides additional system safety in critical applications and prevents media migration-13.

Condensation-proof design — unique condensation-resistant design allows ceramic sensor usage in cold media with condensation formation, ideal for food & beverage applications-13.

2. Bluetooth® Wireless Communication (SmartBlue App)

The PMC51B supports optional Bluetooth® wireless technology for remote operation-45:

Wireless configuration, commissioning, and proof testing from mobile devices without process interruption

Reduces on-site accidents and protects equipment installed in difficult-to-reach areas-32

Enables error-free SIL commissioning and instrument-guided functional safety testing-44

  1. Integrated Diagnostics and Undervoltage Detection

The PMC51B incorporates advanced diagnostic capabilities for enhanced process reliability:

Undervoltage detection — avoids dangerous plant conditions and prevents transmission of frozen current values-44

Integrated digital assistants — ensure fast and error-free commissioning, device locking, and easy measuring point documentation-44

Condition-based maintenance — supports proactive maintenance strategies based on actual device condition-45

  1. SIL 2/3 Capability (IEC 61508)

Development to IEC 61508 ensures improved safety and enables use in safety instrumented systems:

SIL 2 for single-channel applications

SIL 3 with homogeneous redundancy-44

  1. HART Communication Technical Details

The 4…20 mA HART output offers three selectable operating modes:

4.0 … 20.5 mA — standard range

NAMUR NE 43 — 3.8 … 20.5 mA (factory setting)

US mode — 3.9 … 20.8 mA

Signal on alarm follows NAMUR NE 43. The pressure signal is the calculated value after damping and position adjustment-. In a HART Multidrop loop, only one device may use the analog current value for signal transmission-.

6. PROFINET over Ethernet-APL

The PMC51B supports PROFINET over Ethernet-APL for advanced digital integration:

Seamless connection into Industry 4.0 architectures

Advanced physical layer for process automation-1

Application-Specific Recommendations

Application Recommended Model Key Parameter
General industrial pressure monitoring PMC51B-AAAAABA63CAAAAAJD+FA 40 bar, G½ thread, analog output, local display
Chemical processing (corrosive media) PMC51B-AABAABH63EJA1VXJG 40 bar, ceramic membrane, FKM seals, aluminum housing
Food & beverage (condensation risk) PMC51B with condensation-proof design Cold media, hygienic connections, FDA-conforming materials
Vacuum applications PMC51B-AABADBA63PBI1WWCD Fully vacuum resistant up to +100°C
High-pressure hydraulic systems PMC51B with 40 bar range G½ thread, aluminum housing, local display
Safety instrumented systems (SIL) PMC51B with SIL 2/3 certification IEC 61508 compliant
PROFINET / Industry 4.0 integration PMC51B-CCBADBH63KEA1VNJD PROFINET over Ethernet-APL, local display
Hazardous area (Ex zone) PMC51B with ATEX/IECEx approval Ex i, Ex d, or Ex e protection
Water treatment / drinking water PMC51B with NSF/KTW approval Drinking water certified materials
Pharmaceutical (FDA compliance) PMC51B with FDA-conforming materials Hygienic design, validation ready

Field of application: The Cerabar PMC51B measures absolute and gauge pressure accurately and reliably in liquids and gases-45. Extended applications are enabled by measuring ranges from 5 mbar to 420 bar and process temperatures from -70°C to +400°C (with appropriate diaphragm seal configurations)-44.

Comparison: PMC51B vs. PMP51B

The Cerabar series offers two sensor technologies for different application needs:

Feature PMC51B (Ceramic) PMP51B (Metallic)
Sensing technology Capacitive ceramic Piezoresistive metal
Pressure range 100 mbar … 40 bar (1.5 … 600 psi) Up to 400 bar (6,000 psi)
Fill fluid None — dry measuring cell Silicone oil (or alternative)
Vacuum capability Fully vacuum resistant Limited by fill fluid
Chemical resistance Excellent (ceramic) Good (316L, Hastelloy)
Temperature range (standard) -40 … +100°C -40 … +125°C
Reference accuracy (Platinum) Up to 0.055% Up to 0.055%
Membrane breakage detection Integrated Available
Best suited for Corrosive media, vacuum, food & beverage, pharmaceutical High pressure, general industrial

PMC51B advantage: The oil-free ceramic sensor provides superior performance in vacuum applications, with corrosive or abrasive media, and in hygienic/food applications where fill fluid contamination is a concern-13.

Installation & Commissioning

Mounting Guidelines

The PMC51B can be installed via:

Direct thread connection — G½ … G2, R½, MNPT½ … MNPT2, FNPT½

Flange mounting — DIN, ASME, JIS (DN25 … DN80, NPS 1″ … 4″)

Hygienic connections — Tri-Clamp, DIN11851, aseptic connections available

Using a valve manifold allows for easy commissioning, installation, and maintenance without interrupting the process-. When mounting the device and establishing electrical connections, prevent moisture penetration into the housing-.

Commissioning

The PMC51B offers multiple commissioning options:

Local operation — Optional LCD display with intuitive wizard navigation. The commissioning wizard guides users through the most important configuration parameters-.

Remote operation — SmartBlue App via secure Bluetooth connection for wireless device configuration and proof testing-.

Digital integration — DeviceCare or FieldCare software for PC-based configuration.

Manual commissioning — Using “Zero” and “Span” keys on the electronic insert (press simultaneously for at least 3 seconds)-.

Pre-commissioning checklist:

Perform a post-installation function check before putting the measuring point into operation-

Verify the order code matches the product sticker

Confirm all approvals and certifications match application requirements

Certifications & Compliance

The E&H PMC51B pressure transmitter carries a comprehensive suite of international certifications:

Category Certifications
Explosion protection ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex-6
Functional safety SIL 2 / SIL 3 (IEC 61508)-44
Design / Material EN 10204-3.1, NACE MR0175, NACE MR0103-16
Drinking water NSF, KTW-16
Hygienic Aseptic connections, FDA-conforming materials available
General CE marking, RCM

SEO Best Practices Applied

This technical datasheet incorporates the following SEO strategies for independent site ranking:

Primary keyword: “E&H PMC51B pressure transmitter” — appears in H1 heading and first paragraph without forced repetition

Secondary keywords: “Cerabar PMC51B technical specs,” “PMC51B ordering code breakdown,” “PMC51B-AAAAABA63CAAAAAJD+FA code explanation,” “Endress+Hauser PMC51B model strings”

Natural variation: Uses complete model strings (e.g., PMC51B-AABADBH63PEAAADJD, PMC51B-CCBACBH63PFAAAAJD, PMC51B-AABAABH63EJA1VXJG, PMC51B-AABADBH63MEA1VWJD) distributed across tables and bullet points

Readability: Short sentences, bullet points, comparison tables, and structured headings improve dwell time

Unique content: All model breakdowns and technical data compiled from official Endress+Hauser TI/BA documents — no copy-paste from competitors

Technical depth: Detailed HART protocol specifications, supply voltage ranges, vacuum resistance parameters, and alarm configurations for advanced users

Obtain relevant certificates and quotations for the product

Scroll to Top

Send Us a Message