pressure transmitter,temperature Transmitter,flow meter-ST-YK CLD

E&H PMD55 pressure transmitter

Model:PMD55-BA32AA27BGBHAJA1A+AA

Manufacturer: ENDRESS + HAUSER

Size:25*25*30cm

Detail Specification: pressure transmitter

Comment:Carton

Shipping Weight: 8Kg

Estimated Lead Time: 8 Weeks

Payment:T/T

HS CODE:9026201090

 

product details

E&H PMD55 pressure transmitter

Overview

The E&H PMD55 pressure transmitter is a differential pressure device from Endress+Hauser’s Deltabar M series. Equipped with a piezoresistive sensor and welded metallic isolating diaphragm, it provides continuous measurement of pressure differences in liquids, vapors and gases across process and environmental applications-17. Typical measuring tasks include flow measurement (volume or mass flow) using primary elements, hydrostatic level measurement in pressurized vessels, and differential pressure monitoring of filters and pumps-11-.

Core Technology: Piezoresistive Sensor with Welded Metallic Membrane

Unlike ceramic-based transmitters, the PMD55 employs a proven piezoresistive sensing element with a welded metal membrane filled with silicone oil or inert fill fluid for pressure transfer-. This construction ensures robust performance in harsh industrial environments where corrosion resistance and long-term stability are critical. The metal membrane is available in 316L or AlloyC, offering flexibility for aggressive media exposure-11.

Technical Specifications

ParameterSpecification
Reference Accuracy (Standard)±0.1% of set span
Reference Accuracy (Platinum)±0.075% of set span (optional)
Pressure Measuring Range10 mbar to 40 bar (0.15 to 580 psi)
Minimum Calibratable Span10 mbar (0.145 psi)
Turn Down Ratio100:1 or higher
Long-term Stability0.05% of URL per year; 0.125% of URL per 5 years
Process Temperature-40 to +85°C (-40 to +185°F)
Ambient Temperature-40 to +85°C (-40 to +185°F)
Maximum Overpressure (Single Side)160 bar (2300 psi)
Supply Voltage (4–20mA HART, Non-Ex)11.5 to 45 V DC
Supply Voltage (4–20mA HART, Ex ia)11.5 to 30 V DC
Supply Voltage (PROFIBUS PA / FF)9 to 32 V DC (Non-Ex)
Ingress ProtectionIP66 / IP67 / NEMA4X/6P

All performance data conform to ≥ ±3 sigma confidence levels, ensuring batch-to-batch consistency across all production units-17-11-5.

Order Code Deep Dive: PMD55-BA32AA27BGBHAJA1A+AA

Endress+Hauser employs a structured order code system. The configuration PMD55-BA32AA27BGBHAJA1A+AA breaks down as follows:

PMD55 — Deltabar M differential pressure transmitter with piezoresistive metal sensor

BA32 — Approval/Output/Display: ATEX II 1/2 G Ex d IIC T6 Ga/Gb; 4–20 mA HART; LCD display with push-button operation

AA — Housing: F30 aluminum with glass window

27 — Electrical connection: Gland M20, IP66/67 NEMA4X/6P

B — Process connection: Threaded

G — Sensor range: Measuring cell 40 bar (580 psi)

B — Reference accuracy: Standard (±0.1%)

HAJ — Calibration and unit: Custom calibration; mbar/bar units

A1A — Additional options: Standard (no special options)

+AA — Extended configuration suffix

This configuration is ideally suited for hazardous-area differential pressure monitoring requiring ATEX flameproof protection and local display operation-13.

Additional PMD55 Configurations

The PMD55 platform supports diverse application requirements through extended order codes:

PMD55-AA21BA27BGBHAJA1F — Non-hazardous approval, 4–20 mA HART, LCD display, F30 aluminum housing, M20 gland, 10 mbar sensor, 316L membrane-13

PMD55-FA22AD67HGFHA4A1A+AA — ±0.1% accuracy, 4–20 mA HART, 0–45 psi range, 1/4″ NPT process connection-

PMD55-AA21BD67LGFHAJA1J — 4–20 mA HART, 0.5 mbar to 40 bar measuring range, ±0.1% accuracy-17

PMD55-FC21BD27CGJHAJA1AZ1 — Specialized configuration with enhanced electronics features-17

PMD55-BA21BA27BGBHAJA1A — ATEX approval, -40 to +85°C ambient temperature, robust Deltabar M design-

PMD55-AA21BA67DGCHA4A1A — -1 to +1 kPa range, threaded process connection-

PMD55-AA21BA27BGCHA4A1A — -10 to +10 kPa range, suitable for low-differential applications-

PMD55-AA21BD67HDFHAJA1CN3PJ — Extended configuration with NACE material certification-17

PMD55-AA22AD67LGFHA4A1AAAN3PJ — High-end variant with NACE MR0175 compliance-17

The broad range — from PMD55-AA21BA27BGBHAJA1F to PMD55-FC21BD27CGJHAJA1AZ1 — demonstrates the transmitter’s adaptability across industries including oil and gas, chemical processing, water treatment, and environmental monitoring-.

Communications and Certifications

The PMD55 supports multiple communication protocols: 4–20 mA HART (standard), PROFIBUS PA, and FOUNDATION Fieldbus. A DIP switch on the main electronics allows quick adaptation to impulse line high-pressure/low-pressure changes without configuration tools-.

Certifications include ATEX, FM, CSA, IECEx, INMETRO, NEPSI, and TIIS explosion protection-17. The device is SIL2 certified according to IEC 61508 / IEC 61511, suitable for safety instrumented systems (SIS)-17-. Material certifications include NACE MR0103, NACE MR0175, and EN10204-3.1 for corrosion-critical applications-12.

Commissioning and Operation

The PMD55 features Quick Setup with adjustable measuring range, enabling simple commissioning that reduces costs and saves time-. Configuration options include:

Menu-guided local operation via optional LCD display with three push buttons-

DIP switch-based setup for basic parameter adjustment without display

Remote configuration via HART communicator, FieldCare, or DeviceCare

PROFIBUS PA / FOUNDATION Fieldbus for integrated plant automation

The modular design allows field replacement of display and electronics components, minimizing downtime and simplifying maintenance.

Wetted Materials and Process Connections

ComponentMaterial Options
Process Membrane316L stainless steel, AlloyC
SealsViton, PTFE, EPDM, NBR
Fill FluidSilicone oil, inert oil (optional)
Housing MaterialPowder-coated aluminum or AISI 316L stainless steel

Process connection types: Threaded 1/4″ NPT, G½, and other custom configurations-11.

Field of Application

The Deltabar M PMD55 is engineered for:

Flow measurement — Volume or mass flow using pitot tubes, orifice plates, or Venturi nozzles in gases, vapors, and liquids-

Level measurement — Hydrostatic level in pressurized vessels and open tanks

Differential pressure monitoring — Filter differential pressure, pump monitoring, and pipeline blockages-5

Environmental applications — Continuous measurement of pressure differences in liquids, vapors, and gases-17

 

Conclusion

The Endress+Hauser Deltabar M PMD55 pressure transmitter series combines piezoresistive metal sensor technology with modular flexibility and SIL2 safety certification. From the standard PMD55-BA32AA27BGBHAJA1A+AA to specialized variants like PMD55-FA22AD67HGFHA4A1A+AA and PMD55-AA21BD67LGFHAJA1J, specifiers can obtain precisely configured devices for demanding differential pressure, flow, and level applications across process industries worldwide.

 

Obtain relevant certificates and quotations for the product

Scroll to Top