E&H PMD75 pressure transmitter
Model:PMD75-ABB7CC2ECAB
Manufacturer: ENDRESS + HAUSER
Size:25*25*30cm
Detail Specification: pressure transmitter
Comment:Carton
Shipping Weight: 8Kg
Estimated Lead Time: 8 Weeks
Payment:T/T
HS CODE:9026201090
product details
E&H PMD75 pressure transmitter
1. Product Overview
The E&H PMD75 pressure transmitter features a piezoresistive sensor with a welded metallic membrane, delivering exceptional accuracy, long-term stability, and overload resistance-13. The E&H PMD75-ABB7CC2ECAB belongs to the Deltabar S platform, a modular transmitter family that supports seamless integration with HART, PROFIBUS PA, and FOUNDATION Fieldbus communication protocols-7.
A three-key pushbutton interface enables straightforward commissioning and operation, while the integrated HistoROM data module facilitates efficient management of process and device parameters. The device is certified for functional safety up to SIL2/SIL3 according to IEC 61508-1.
2. Complete Technical Specifications
| Parameter | Specification |
| Measuring Principle | Differential pressure, piezoresistive sensor with welded metallic membrane-1 |
| Reference Accuracy (Standard) | 0.05% of span-1 |
| Reference Accuracy (Platinum) | Up to 0.035% of span-1 |
| Max. Measurement Error | 0.075% (standard) / 0.05% (platinum)-12 |
| Turn Down Ratio | Up to 100:1 (higher on request)-13 |
| Pressure Measuring Range | 10 mbar to 250 bar (0.15 psi to 3,750 psi)-1 |
| Process Pressure / Max. Overpressure Limit | 420 bar (42 MPa / 6,300 psi)-1 |
| Process Temperature Range | –40°C to +85°C (–40°F to +185°F)-12 |
| Ambient Temperature Range | –40°C to +85°C (–40°F to +185°F)-1 |
| Supply Voltage (4-20 mA HART, non-Ex) | 10.5 to 45 V DC-1 |
| Supply Voltage (4-20 mA HART, Ex ia) | 10.5 to 30 V DC-1 |
| Supply Voltage (PROFIBUS PA / FF) | 9 to 32 V DC-1 |
| Long-term Stability | 0.05% of URL per year-1 |
| Main Wetted Parts | Alloy C276, 316L, Monel, Tantalum-12 |
| Process Membrane Material | 316L, AlloyC, Tantalum, Gold-Rhodium-12 |
| Max. Measurement Distance | 400 m H₂O-12 |
| Output Signals | 4-20 mA with HART, PROFIBUS PA, FOUNDATION Fieldbus-1 |
| Hazardous Area Approvals | ATEX, FM, CSA, IECEx, INMETRO, NEPSI, TIIS-1 |
| Enclosure Rating | IP66 / IP67, NEMA 6P |
| Housing Material | Die-cast aluminum or 316L stainless steel (optional) |
3. Order Code Breakdown: E&H PMD75-ABB7CC2ECAB
The E&H PMD75-ABB7CC2ECAB represents a fully configured differential pressure transmitter with specific selections for approval, output, housing, nominal range, calibration, and process connection. Below is the decoded configuration:
| Position | Code | Meaning |
| Product Family | PMD75 | Deltabar S differential pressure transmitter |
| A (Approval) | A | Non-hazardous area |
| B (Output) | B | 4-20 mA HART, external + LCD display |
| B (Housing) | B | Housing T14, aluminum, IP66/67 NEMA 6P |
| 7 (Cover Sealing) | 7 | EPDM sealing |
| C (Cable Entry) | C | M20 thread, side cover |
| C (Nominal Range) | C | Measuring cell 30 mbar / 3 kPa / 0.45 psi |
| 2 (Membrane Material) | 2 | 316L stainless steel |
| E (Calibration Unit) | E | Custom calibration unit (per additional specification) |
| C (Process Connection) | C | NPT1/4-18, IEC61518, UNF7/16-20 |
| A (Seal Material) | A | FKM Viton |
| B (Additional Options) | B | Mounting bracket, wall/pipe, 316L, standard design |
This configuration is well-suited for low-differential pressure applications requiring 4-20 mA HART communication, local display, and 316L wetted parts for compatibility with mildly corrosive media-12-7.
4. Performance Characteristics
The E&H PMD75 pressure transmitter achieves a reference accuracy of up to 0.035% when ordered with the Platinum option, making it suitable for custody transfer and high-precision flow measurement applications-7. The long-term stability of 0.05% of URL per year ensures sustained measurement reliability over extended operational periods-1.
For dynamic response, the dead time of the E&H PMD75-ABB7CC2ECAB is typically under 100 milliseconds for the HART output variant, with adjustable damping from 0 to 999 seconds to accommodate process noise and pulsation-7. The device supports a turn-down ratio of 100:1, allowing a single transmitter to cover a wide range of operating conditions without recalibration-13.
5. Communication and Integration
The E&H PMD75 pressure transmitter supports three primary communication protocols:
4-20 mA HART — Universal analog output with digital HART communication for parameterization and diagnostics. Supply voltage range: 10.5–45 V DC (non-Ex)-1.
PROFIBUS PA — Digital fieldbus communication compliant with IEC 61158-2, enabling integration into process automation systems. Supply: 9–32 V DC-1.
FOUNDATION Fieldbus — Same electrical layer as PROFIBUS PA, supporting device description and function block-based control strategies-1.
The modular design of the E&H PMD75-ABB7CC2ECAB allows field replacement of sensor, electronics, or display modules without recalibration, reducing downtime and maintenance costs-1.
6. Applications
The E&H PMD75 pressure transmitter is deployed in the following primary applications:
Flow measurement — Volume or mass flow measurement in conjunction with differential pressure primary elements (orifice plates, pitot tubes, Venturi tubes) for gases, vapors, and liquids-7.
Level measurement — Level, volume, or mass measurement in liquids, including interface detection and density compensation-7.
Differential pressure monitoring — Filter monitoring, pump differential pressure surveillance, and heat exchanger pressure drop tracking-7.
High-temperature applications — When paired with diaphragm seals, the E&H PMD75-ABB7CC2ECAB can support process temperatures up to 400°C (752°F)-7.
7. Safety and Compliance
The E&H PMD75 pressure transmitter is designed to IEC 61508 and certified by TÜV SÜD for functional safety applications up to SIL3-13. Key safety features include:
Gas-tight feedthrough providing a secondary process barrier
Continuous function monitoring from measuring cell to electronics
Self-diagnostic functions for early fault detection
Overload resistance up to 420 bar with function-monitored design-1
International explosion protection approvals include ATEX, FM, CSA, IECEx, INMETRO, NEPSI, and TIIS, ensuring global deployment capability in hazardous areas-1. Additional certifications include WHG overfill prevention, marine approvals, and NACE compliance for sour service environments-46.
8. Ordering Information
| Field | Value |
| Manufacturer | Endress+Hauser |
| Product Series | Deltabar S |
| Base Model | PMD75 |
| Full Order Code | PMD75-ABB7CC2ECAB |
| Country of Origin | Germany |
| Compliance | CE, RoHS |
For additional order code variants or custom configurations, please consult the official Endress+Hauser product configurator or contact our technical sales team with your specific application requirements.