E&H PMD78 pressure transmitter
Model:FMD78-AAB7DBEAFAAA
Manufacturer: ENDRESS + HAUSER
Size:45*25*50cm
Detail Specification: pressure transmitter
Comment:Carton
Shipping Weight: 50Kg
Estimated Lead Time: 8 Weeks
Payment:T/T
HS CODE:9026201090
product details
E&H PMD78 pressure transmitter
1. Product Overview
The E&H PMC78 pressure transmitter features a metallic sensor with two capillary diaphragm seals, delivering exceptional accuracy, long-term stability, and overload resistance. Unlike traditional differential pressure transmitters that require impulse piping, the PMC78 employs an electronic dp system consisting of two metal sensors and one transmitter, calculating differential pressure from both sensors and transmitting level, volume or mass via digital outputs.
The PMC78-AAB7DBEAFAAA belongs to the Deltabar S platform, a modular transmitter family that supports seamless integration with HART, PROFIBUS PA, and FOUNDATION Fieldbus communication protocols. A four-line digital display and three-key pushbutton interface enable straightforward commissioning and operation, while the integrated HistoROM data module facilitates efficient management of process and device parameters.
2. Complete Technical Specifications
| Parameter | Specification |
| Measuring Principle | Differential pressure, metallic sensor with two capillary diaphragm seals |
| Reference Accuracy | 0.075% of span + influence of diaphragm seal |
| Turn Down Ratio | Up to 100:1 |
| Pressure Measuring Range | 100 mbar to 40 bar (1.5 psi to 600 psi) |
| Process Pressure / Max. Overpressure Limit | 160 bar (2400 psi) |
| Process Temperature Range | –40°C to +400°C (–40°F to +752°F) |
| Ambient Temperature Range | –40°C to +85°C (–40°F to +185°F) |
| Supply Voltage (4-20 mA HART, non-Ex) | 10.5 to 45 V DC |
| Supply Voltage (4-20 mA HART, Ex ia) | 10.5 to 30 V DC |
| Supply Voltage (PROFIBUS PA / FOUNDATION Fieldbus) | 9 to 32 V DC |
| Long-term Stability | <0.05% of URL per year |
| Main Wetted Parts | Alloy C276, 316L, Monel, Tantalum |
| Process Membrane Material | 316L, AlloyC, Tantalum, Gold-Rhodium |
| Max. Measurement Distance | 400 m H₂O |
| Output Signals | 4-20 mA with HART, PROFIBUS PA, FOUNDATION Fieldbus |
| Hazardous Area Approvals | ATEX, FM, CSA, IECEx, INMETRO, NEPSI, EAC |
| Hygienic Approvals | 3A, EHEDG |
| Enclosure Rating | IP66 / IP67, NEMA 6P |
| Housing Material | Die-cast aluminum (T14/T15) or 316L stainless steel |
3. Order Code Breakdown: PMC78-AAB7DBEAFAAA
The PMC78-AAB7DBEAFAAA represents a fully configured electronic differential pressure transmitter with specific selections for approval, output, housing, nominal range, calibration, and process connection. Below is the decoded configuration based on the Deltabar S FMD78 order code structure:
| Position | Code | Meaning |
| Product Family | FMD78 | Deltabar S electronic differential pressure transmitter with two diaphragm seals |
| A (Approval) | A | Non-hazardous area |
| A (Output) | A | 4-20 mA HART, external + LCD display |
| B (Housing) | B | Housing T14, aluminum, IP66/67 NEMA 6P |
| 7 (Cable Entry) | 7 | M20 thread, side cover |
| D (Nominal Range) | D | Measuring cell 500 mbar / 7.5 psi |
| B (Membrane Material) | B | 316L stainless steel |
| E (Calibration Unit) | E | Custom calibration unit (per additional specification) |
| A (Process Connection) | A | Diaphragm seal with flange connection |
| F (Seal Material) | F | FKM Viton |
| A (Diaphragm Seal Fill Fluid) | A | Silicone oil |
| A (Diaphragm Seal Material) | A | 316L stainless steel |
| A (Additional Options) | A | Standard design without special options |
This configuration is well-suited for differential pressure and level applications requiring 4-20 mA HART communication, local display, and 316L wetted parts for compatibility with mildly corrosive media.
4. Performance Characteristics
The E&H PMC78 pressure transmitter achieves a reference accuracy of 0.075% of span, making it suitable for high-precision flow and level measurement applications. The long-term stability of less than 0.05% of URL per year ensures sustained measurement reliability over extended operational periods.
For dynamic response, the dead time of the PMC78 is typically under 100 milliseconds for the HART output variant, with adjustable damping from 0 to 999 seconds to accommodate process noise and pulsation. The device supports a turn-down ratio of 100:1, allowing a single transmitter to cover a wide range of operating conditions without recalibration.
The TempC membrane technology incorporated in the PMC78-AAB7DBEAFAAA diaphragm seals minimizes temperature effects and ensures short recovery times, delivering stable measurements even under fluctuating thermal conditions.
5. Communication and Integration
The E&H PMC78 pressure transmitter supports three primary communication protocols:
4-20 mA HART — Universal analog output with digital HART communication for parameterization and diagnostics. Supply voltage range: 10.5–45 V DC (non-Ex).
PROFIBUS PA — Digital fieldbus communication compliant with IEC 61158-2, enabling integration into process automation systems. Supply: 9–32 V DC.
FOUNDATION Fieldbus — Same electrical layer as PROFIBUS PA, supporting device description and function block-based control strategies.
The modular design of the PMC78-AAB7DBEAFAAA allows field replacement of sensor, electronics, or display modules without recalibration, reducing downtime and maintenance costs.
6. Applications
The E&H PMC78 pressure transmitter is deployed in the following primary applications:
Flow measurement — Volume or mass flow measurement in conjunction with differential pressure primary elements (orifice plates, pitot tubes, Venturi tubes) for gases, vapors, and liquids.
Level measurement — Level, volume, or mass measurement in liquids, including interface detection and density compensation.
Differential pressure monitoring — Filter monitoring, pump differential pressure surveillance, and heat exchanger pressure drop tracking.
Hygienic applications — When equipped with appropriate hygienic connections, the PMC78 is certified for use in food, beverage, and pharmaceutical industries (3A, EHEDG approvals).
7. Safety and Compliance
The E&H PMC78 pressure transmitter is designed according to IEC 61508 and certified for functional safety applications up to SIL3. Key safety features include:
Gas-tight feedthrough providing a secondary process barrier
Continuous function monitoring from measuring cell to electronics
Self-diagnostic functions for early fault detection
Overload resistance up to 160 bar with function-monitored design
International explosion protection approvals include ATEX, FM, CSA, IECEx, INMETRO, NEPSI, and EAC, ensuring global deployment capability in hazardous areas. Additional certifications include overfill prevention WHG, marine approvals, and NACE compliance for sour service environments.
8. Ordering Information
| Field | Value |
| Manufacturer | Endress+Hauser |
| Product Series | Deltabar S |
| Base Model | FMD78 |
| Full Order Code | FMD78-AAB7DBEAFAAA |
| Country of Origin | Germany |
| Compliance | CE, RoHS |
For additional order code variants or custom configurations, please consult the official Endress+Hauser product configurator or contact our technical sales team with your specific application requirements.