pressure transmitter,temperature Transmitter,flow meter-ST-YK CLD

E&H PMP43 pressure transmitter

Model:PMP43-AAKACFN6A3FABA29YYA3

Manufacturer: ENDRESS + HAUSER

Size: 25*25*35cm

Detail Specification: pressure transmitter

Comment:Carton

Shipping Weight: 8Kg

Estimated Lead Time: 12 Weeks

Payment:T/T

HS CODE:9026201090

product details

E&H PMP43 pressure transmitter

Product Overview

The Endress+Hauser Cerabar PMP43 is a compact hygienic pressure transmitter engineered for demanding sanitary applications in the food & beverage, pharmaceutical, and life sciences industries-3. Part of the Compact Line portfolio, the PMP43 combines a space-saving design with full performance capabilities, making it an ideal solution for pressure and hydrostatic level measurement in pipelines, process vessels, and storage tanks-5.

The PMP43 utilizes a metal process membrane and robust sensor technology suitable for measuring both absolute and gauge pressure in liquids and gases-11. Its fully welded stainless steel construction ensures cleanability and contamination prevention, while optional Heartbeat Technology enables predictive maintenance and on-demand verification without process interruption-13.

Key Specifications

Parameter Value
Measuring Principle Absolute and gauge pressure
Pressure Measuring Range 400 mbar … 100 bar (6 psi … 1450 psi)
Smallest Calibratable Span 20 mbar (0.3 psi)
Max. Turn Down 20:1
Reference Accuracy (Standard) ±0.1%
Reference Accuracy (Platinum) ±0.075%
Long-Term Stability 0.1% of URL/year; 0.2% of URL/5 years; 0.25% of URL/10 years
Process Temperature –40°C … +130°C (standard); –20°C … +200°C (optional)
Ambient Temperature –40°C … +85°C (–40°F … +185°F)
Supply Voltage (4-20mA HART, Non-Ex) 11.5 … 45 VDC
Supply Voltage (Ex ia) 11.5 … 30 VDC
Output / Communication 4-20 mA analog; 4-20 mA HART; 4-20 mA IO-Link; optional Bluetooth
Process Membrane Material 316L stainless steel
Housing Material 316L stainless steel (hygienic design)
Ingress Protection IP69 (360° hygienic design)
Process Connections Thread: G½ … G2, R½, MNPT¾ … MNPT2, FNPT½; Flange: DN25 … DN80, NPS 1″ … 3″; Hygienic: Tri-Clamp, DIN11851, DIN11864-1, NEUMO, Varivent, SMS, DRD, universal adapter
Vacuum Resistance 50 mbar (0.725 psi)

Feature Highlights

Outstanding Ease of Use – Guided wizards and an intuitive touch display simplify commissioning, verification, and periodic proof testing-. The user interface is harmonized across measurement technologies, reducing training time and enabling standardization.

Process & Product Safety – A checksum algorithm (CRC) ensures that safety-relevant parameters remain unchanged, providing configuration integrity-11.

Heartbeat Technology – This smart diagnostic feature enables traceable, documented on-demand verification without process interruption. It also provides permanent monitoring of process anomalies and blocked impulse lines, boosting overall plant productivity-5.

Hygienic Design – The 360° hygienic design and IP69 ingress protection rating enable efficient cleaning and avoid contamination. Certified hygienic approvals include 3-A, EHEDG, and CoC-ASME BPE, ensuring documented material conformity and traceability-13.

Flexible Communication – The PMP43 supports 4-20 mA analog, HART, and IO-Link communication protocols. IO-Link facilitates digital plant transformation, while optional Bluetooth allows wireless setup and monitoring via the SmartBlue app-12.

Application Areas

The Cerabar PMP43 is suitable for a wide range of hygienic applications:

Pressure monitoring of process pipes

Hydrostatic level measurement in process tanks and pressurized vessels

Pressure monitoring in narrow skids and modules

Clean-in-place (CIP) environments

Medical ventilation systems-12

 

Model Code Breakdown: PMP43-AAKACFN6A3FABA29YYA3

The complete PMP43 ordering code follows Endress+Hauser’s structured product configuration system, where each character position corresponds to a specific device feature. Below is a detailed interpretation of PMP43-AAKACFN6A3FABA29YYA3.

Base Model: PMP43

PMP43 — Cerabar hygienic pressure transmitter, Compact Line

Position 1-3: Approval

AAK — ATEX / IECEx / UKEX approval for Zone 0, 1, 2 gas and dust; Non-incendive for Zone 2 (CSA C/US)

Position 4: Communication Protocol / Output

A — 4-20 mA HART

Position 5-7: Pressure Range / Measuring Cell

CFN6 — Measuring cell: 400 mbar … 100 bar range; 316L process membrane; Overload limit 150 bar

Position 8: Process Connection

A3 — Hygienic process connection: Tri-Clamp 1½″ ISO2852, DN40 (316L)

Position 9-10: Seal / Sensor Filling Fluid

FA — Seal material: No seal (diaphragm welded); Filling fluid: Synthetic oil FDA compliant

Position 11: Wetted Surface Roughness

B — Ra ≤ 0.76 µm (30 µin), mechanically polished

Position 12-13: Housing Type / Cable Entry

A2 — Housing: 316L hygienic (stainless steel), IP69; Cable entry: M20x1.5

Position 14-15: Display / Operation

9Y — Display: 4-line LCD touch display with backlight; Language: English (standard)

Position 16: Output Additional Option

Y — No additional output

Position 17: Factory Calibration

A3 — Factory calibration certificate included

Obtain relevant certificates and quotations for the product