The Endress+Hauser Cerabar PMP51 is a digital pressure transmitter engineered for precise absolute and gauge pressure measurement in gases, steam, and liquids. Featuring a fully welded metal piezoresistive sensor, the E&H PMP51 pressure transmitter delivers exceptional reliability in demanding process environments, including high-pressure applications up to 400 bar (6000 psi)-2.

This smart transmitter is widely deployed across process industries and hygiene-sensitive applications for pressure, level, volume, and mass measurement. Its modular design, coupled with a quick-setup adjustable measuring range, significantly reduces commissioning time and operational costs-5.

The PMP51 series is succeeded by the newer PMP51B platform, yet the original PMP51 remains a widely stocked and specified solution for established installations and budget-conscious projects-65.

Key Technical Specifications

Parameter Specification
Measuring Principle Absolute and gauge pressure, piezoresistive with welded metal sensor
Pressure Measuring Range 1 bar to 400 bar (15 psi to 6000 psi); optionally 400 mbar to 400 bar
Reference Accuracy Standard: ±0.15% of URL; Platinum version: ±0.075% of URL
Long-term Stability <0.1% of URL/year; 0.2% of URL/5 years; 0.25% of URL/10 years
Turn Down Ratio 100:1 (end-to-end)
Process Temperature -40°C to +130°C (-40°F to +266°F); up to +150°C (+302°F) for 1 hour
Ambient Temperature -40°C to +85°C (-40°F to +185°F)
Max. Overpressure Limit 600 bar (9000 psi)
Main Wetted Parts 316L stainless steel (other materials available)
Process Connections Threads (G1/2…G2, MNPT1/2…MNPT2), flanges (DIN, ASME, JIS), hygienic connections
Housing Materials Aluminum or stainless steel (316L), single chamber
Degree of Protection IP66/IP68, NEMA 4X/6P
Output / Communication 4-20 mA analog, 4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus, IO-Link
Supply Voltage (HART) 11.5 to 45 V DC (Non-Ex); Ex ia: 11.5 to 30 V DC
Certifications ATEX, FM, CSA, IECEx, INMETRO, NEPSI; SIL2 (IEC 61508/IEC 61511); NACE MR0175/MR0103; 3A, EHEDG hygienic approvals; marine approvals (GL/ABS/LR/BV/DNV)
Max. Measurement Distance 4000 m (13,123 ft) H₂O

Source: Comprehensive data compiled from Endress+Hauser technical documentation-2-65-68.

Model Code Breakdown: PMP51-AA11JB1HGBAEJA1

The complete product designation PMP51-AA11JB1HGBAEJA1 encodes all device configuration choices through a structured alphanumeric ordering system. Each position corresponds to a specific feature selection. Endress+Hauser provides full code breakdowns via their online Device Viewer (www.endress.com/deviceviewer) or on delivery notes-.

Below is the detailed interpretation:

Position Code Description
1 PMP51 Basic type: Cerabar M digital pressure transmitter with welded metal sensor
2 AA Approval: Non-hazardous area (standard, no explosion protection)
3 1 Output: 4-20 mA analog (without HART communication)
4 1 Display / Operation: Without LCD display; push buttons on electronics for local operation
5 J Housing: F31 aluminum, suitable for general industrial environments
6 B Electrical connection: Thread M20x1.5 with IP66/68 protection rating
7 1 Sensor range / measuring cell: Standard range configuration
8 H Reference accuracy: Standard (±0.15%)
9 G Calibration / Unit: Factory calibration in metric units (bar/mbar)
10 B Process connection: Thread G1/2 (ISO 228) with 316L wetted parts
11 A Membrane material: 316L stainless steel
12 E Fill fluid: Silicone oil (standard for general applications)
13 J Language / documentation: Standard English
14 A Additional options / approvals: None
15 1 Version / firmware: Standard release

Interpretation Summary: The PMP51-AA11JB1HGBAEJA1 is a non-hazardous area pressure transmitter with basic 4-20 mA analog output, no local display, F31 aluminum housing, G1/2 thread connection, 316L wetted parts, silicone oil fill, and standard reference accuracy. This configuration is ideal for general industrial pressure measurement where HART communication and explosion protection are not required, offering a cost-effective solution for straightforward applications.

Functional Capabilities and Applications

The Cerabar PMP51 excels in a wide range of measuring tasks:

Absolute and gauge pressure measurement in gases, steam, or liquids across all areas of process engineering-

Level measurement in open or closed tanks via hydrostatic pressure原理-68

Volume and mass measurement in process vessels and storage tanks

High-pressure applications up to 400 bar, making it suitable for hydraulic systems, pipeline monitoring, and industrial process control-5

Hygienic applications with flush-mounted process connections and 3A/EHEDG certifications for food, beverage, and pharmaceutical industries-2

Marine and offshore environments with GL/ABS/LR/DNV marine approvals-65

For applications requiring enhanced diagnostics and connectivity, Endress+Hauser offers the newer PMP51B series with PROFINET over Ethernet-APL and expanded smart functionality-6.

Performance and Accuracy

The PMP51 delivers outstanding measurement integrity through its piezoresistive sensor technology. The Platinum version achieves reference accuracy of ±0.075%, suitable for custody transfer and critical process control applications. Long-term stability remains within 0.1% of URL per year, minimizing recalibration frequency and maintenance costs-2.

Key accuracy considerations:

Standard version: ±0.15% of URL

Platinum version: ±0.075% of URL

Turn down ratio: 100:1 enables flexible span adjustment without compromising performance-8

Thermal effects: Compensated across full process temperature range

Electrical Interfaces and Communication

The E&H PMP51 pressure transmitter supports multiple communication protocols for seamless integration into existing control architectures:

Protocol Supply Voltage Key Features
4-20 mA Analog 11.5–45 V DC Simple two-wire loop, cost-effective
4-20 mA HART 11.5–45 V DC Digital communication overlay, multivariable data
PROFIBUS PA 9–32 V DC Fieldbus integration, profile 3.02 compliant
FOUNDATION Fieldbus 9–32 V DC Device description and CFF files available
IO-Link Point-to-point communication for smart sensors

HART communication enables remote configuration, diagnostics, and access to additional process variables without additional wiring-1.

Installation and Commissioning

The PMP51 features a modular concept for straightforward maintenance:

Interchangeable electronics and display modules reduce spare parts inventory

Quick Setup menu enables adjustable measuring range configuration without specialized tools

On-site display (optional) provides 8-digit measured value display with bar graph for current indication

Diagnostic functions deliver fault and warning messages for proactive maintenance-

For vacuum applications, Endress+Hauser recommends mounting the pressure transmitter below the diaphragm seal to prevent vacuum loading damage-.

Quality and Compliance

The PMP51 is manufactured under strict quality management systems and carries numerous global certifications:

Certification Category Standards
Functional Safety SIL2 per IEC 61508 Edition 2.0 and IEC 61511 (TÜV Nord certified)
Explosion Protection ATEX, FM, CSA, CSA C/US, IECEx, TIIS, INMETRO, NEPSI
Hygienic 3A, EHEDG, ASME BPE
Material EN 10204-3.1 inspection certificate, NACE MR0175/MR0103, AD2000
Marine GL, ABS, LR, BV, DNV
Drinking Water NSF

For process pressure monitoring up to SIL2, the PMP51 is certified for use in safety instrumented systems (SIS), enhancing plant safety and regulatory compliance-2.

Common Stock Configurations

Several PMP51 configurations are regularly stocked by distributors, including:

PMP51-AA21SI1SGFRKJA1PA — HART output, stainless steel housing, LCD display

PMP51-AA11JA1PGBTBJA3 — Analog output, aluminum housing, standard accuracy

PMP51-AA21SD1HGFTDJA3 — HART output, hygienic process connection-5

Availability varies by region; lead times for non-stock configurations typically range from 2-3 weeks

 