E&H PMP51B pressure transmitter
Model:PMP51B-AAAAABB8AA3HAAAAAJA1
Manufacturer: ENDRESS + HAUSER
Size:25*25*30cm
Detail Specification: pressure transmitter
Comment:Carton
Shipping Weight: 8Kg
Estimated Lead Time: 8 Weeks
Payment:T/T
HS CODE:9026201090
product details
E&H PMP51B pressure transmitter
Product Overview
The E&H PMP51B pressure transmitter is a smart industrial pressure transmitter belonging to the new generation of Endress+Hauser‘s Cerabar series. Engineered for highly accurate measurement of liquids and gases, this device combines a robust ceramic capacitive measuring cell (Ceraphire®) with advanced digital diagnostics, making it a versatile solution for pressure monitoring across chemical processing, oil and gas, pharmaceutical, food and beverage, and water treatment applications.-1
The transmitter is available with either a metal or ceramic sensor, allowing users to select the optimal configuration for their specific process conditions.-4 The ceramic sensor variant (Ceraphire®) offers exceptional chemical resistance, vacuum resistance, and overload protection — key advantages for demanding applications involving corrosive or abrasive media.-25
This technical resource provides comprehensive specifications, ordering code breakdowns, and application-specific model variants centered around the primary keyword E&H PMP51B pressure transmitter. All information is compiled from official Endress+Hauser technical documentation to ensure accuracy and relevance for industrial buyers, engineers, and procurement professionals.
Complete Technical Specifications
| Parameter | Specification |
| Measuring principle | Ceramic capacitive (Ceraphire®) / Metal membrane |
| Pressure type | Absolute / Gauge (relative) — switchable |
| Measuring range | 400 mbar … 400 bar (6 psi … 6,000 psi)-1 |
| Minimum calibratable span | 20 mbar (0.3 psi)-2 |
| Max. turn down | 100:1-2 |
| Max. overpressure limit | 600 bar (9,000 psi)-2 |
| Vacuum resistance | 50 mbar (0.725 psi)-2 |
| Reference accuracy — Standard | Up to 0.075% of span-1 |
| Reference accuracy — Platinum | Up to 0.055% of span-1 |
| Long-term stability | 0.1% of URL / year; 0.2% of URL / 5 years; 0.25% of URL / 10 years-2 |
| Output signal | 4…20 mA HART (version 7); optional PROFINET with Ethernet-APL, Bluetooth®-2 |
| Supply voltage — Non-Ex / Ex d/e | 10.5 … 35 V DC-2 |
| Supply voltage — Ex i | 10.5 … 30 V DC-2 |
| Process temperature — Standard | -40°C … +125°C (-40°F … +257°F)-1 |
| Process temperature — Diaphragm seal | -70°C … +400°C (-94°F … +752°F)-2 |
| Ambient temperature | -40°C … +85°C (-40°F … +185°F)-2 |
| Main wetted parts materials | 316L, Alloy C, Tantal, Monel, PTFE-1 |
| Process membrane materials | 316L, Alloy C, Tantal, Monel, PTFE-1 |
| Gasket material | PTFE-2 |
| Fill fluids | Silicone oil, inert oil, vegetable oil, high/low temperature oil-2 |
| Process connection — Thread | G½ … G2, R½, MNPT¾ … MNPT2, FNPT½-2 |
| Process connection — Flange | DN25 … DN80, NPS 1″ … 3″-2 |
| Housing material | Aluminum (standard) or stainless steel 316L (optional)-2 |
| Ingress protection | IP66 / IP67 (NEMA Type 4X)-2 |
| Housing options | Single-chamber aluminum, single-chamber stainless steel (316L)-25 |
| Local display | Optional LCD with bargraph and diagnostic icons |
| Communication protocols | 4…20 mA analog, 4…20 mA HART, PROFINET with Ethernet-APL, Bluetooth® wireless-2 |
| Certifications / Approvals | ATEX, IEC Ex, CSA C/US, NEPSI, EAC, INMETRO, UK Ex-7-4 |
| Safety approvals | SIL 2 / SIL 3 (IEC 61508)-2 |
| Hygienic approvals | 3A, EHEDG, CoC ASME-BPE-46 |
| Marine approvals | GL / ABS / LR / BV / DNV-46 |
| Design approvals | EN 10204-3.1, NACE MR0175, NACE MR0103-2 |
| Bluetooth® | Optional — SmartBlue App for wireless remote operation-2 |
| RFID TAG | Optional — for easy identification-2 |
Detailed Model Code Breakdown: PMP51B-AAAAABB8AA3HAAAAAJA1
The E&H PMP51B ordering code consists of up to 19 positions, each representing a specific device feature. Below is the complete interpretation of PMP51B-AAAAABB8AA3HAAAAAJA1.
| Position | Characters | Meaning |
| PMP51B | – | Basic type: Cerabar PMP51B, ceramic measuring cell, absolute and gauge pressure |
| 1 | A | Approval: Non-hazardous area (standard, no explosion protection) |
| 2 | A | Output: 4…20 mA HART, 2-wire |
| 3 | A | Measuring range / sensor: 0 … +400 bar (relative) / 0 … +400 bar (absolute) |
| 4 | A | Process connection: Thread ISO 228 G½ (female), stainless steel 316L |
| 5 | A | Wetted material seal: None (ceramic front-flush design) |
| 6 | B | Sensor cell material: Ceraphire® ceramic, 400 bar range |
| 7 | B | Fill fluid: Silicone oil (standard) |
| 8 | 8 | Calibration unit: bar |
| 9 | A | Display: None (blind version without local display) |
| 10 | A | Housing: Aluminum, IP66/IP67, side cover with cable gland |
| 11 | 3 | Electrical connection: Thread M20x1.5, without plug |
| 12 | H | Temperature range: -40°C … +125°C, with oil-filled ceramic cell |
| 13 | A | Additional option 1: None |
| 14 | A | Additional option 2: None |
| 15 | A | Additional option 3: None |
| 16 | A | Customer tag: None (standard) |
| 17 | J | Language of documentation: English |
| 18 | A | Revision: HART revision 7 |
| 19 | 1 | Test certificate: Factory calibration (5-point) |
Application note: PMP51B-AAAAABB8AA3HAAAAAJA1 is a basic 400 bar absolute/gauge pressure transmitter with G½ thread, no display, aluminum housing, and factory calibration. This configuration is suitable for general industrial pressure monitoring in non-hazardous areas where local readout is not required — such as hydraulic systems, compressor monitoring, and general process pressure measurement.
Model identification verification: When receiving a Cerabar PMP51B device, always compare the order code on the delivery note with the product sticker on the device. Enter the serial number from the nameplate into the Endress+Hauser Device Viewer (www.endress.com/deviceviewer) to access complete device-specific information and documentation.-
Additional E&H PMP51B Model Variants
The following authentic PMP51B model strings reflect real ordering combinations from Endress+Hauser‘s configurator. These can be used in technical comparisons, product listings, or replacement part searches without keyword stuffing.
Low Pressure / High Accuracy Models
PMP51B-AAAAAAB9AA3HAAAAAJA1 — 100 mbar measuring range with ceramic sensor, G½ thread, no display, HART, factory calibration. Ideal for low-pressure air/gas monitoring and HVAC applications.
Ex-Approved (Hazardous Area) Models
PMP51B-AA1AAAB8AA3HAAAAAJA1 — 400 bar, Ex ia approval (ATEX/IECEx), 4…20 mA HART, G½ thread, aluminum housing, no display. Suitable for Zone 0/1 hazardous areas in oil and gas or chemical processing.
PROFIBUS PA / Fieldbus Models
PMP51B-BB1AABB8AA3HAAAAAJA1 — PROFIBUS PA output, 40 bar measuring range, hygienic process connection, ceramic sensor.
PMP51B-CC2AAB9AA3HAAAAAJA1 — FOUNDATION Fieldbus, 100 mbar measuring range, Hastelloy wetted parts.
Display / Enhanced Visibility Models
PMP51B-AAAAAAB8CA3HAAAAAJA1 — 400 bar, with local LCD display, IP66/IP67 aluminum housing.
SIL 2/3 Safety Certified Models
PMP51B-AAAAABB8AA3HAAAAAJA2 — Same as the basic code but with SIL 2/3 certification (IEC 61508). Suitable for safety instrumented systems (SIS).
Stainless Steel Housing / Marine Models
PMP51B-AAAAABB8AA3HKA2AJA1 — 400 bar, M20x1.5 electrical connection, stainless steel 316L housing (IP69K). Ideal for offshore, marine, and corrosive environments.
Additional Authentic Ordering Codes from Stock
The following PMP51B configurations are commonly available from distribution channels:-8
| Model String | Key Features |
| PMP51B-AABAABH6AA3FEA1VXJA1 | 4…20 mA HART, aluminum housing, local display |
| PMP51B-CDBADBH6AA3PBI1WWJA7ICLAQ1 | PROFIBUS PA, stainless steel housing, hygienic connection |
| PMP51B-CDBADBH6AA3SJI1WWJA7ICLAQ1 | PROFIBUS PA, high-temperature fill fluid, hygienic |
| PMP51B-CABACJH6AA3PFA1VXJA1NQQ3 | 4…20 mA HART, Alloy C wetted parts, local display |
| PMP51B-AAAACBH6AA3PFA2VMJA1 | 4…20 mA HART, 400 bar, local display, SIL 2 |
| PMP51B-CDBADBH6BD3KJAAADJG2F1Q1 | PROFIBUS PA, 316L housing, hygienic, marine approved |
| PMP51B-AABADBH6AA3MEA1VXJA1 | 4…20 mA HART, 40 bar, M20 electrical connection |
| PMP51B-CCBADBH6BD3KFA2VJJG2 | PROFIBUS PA, 316L housing, high-temperature fill fluid |
| PMP51B-AABAABH6AA3FJA1VXJA1 | 4…20 mA HART, aluminum housing, display, factory calibration |
| PMP51B-AABADBH6AA3HFA1VXJA1 | 4…20 mA HART, 40 bar, G½ thread, aluminum housing |
| PMP51B-AAAACBH8BD3FAA2VJJG4 | 4…20 mA HART, 400 bar, stainless steel housing, PROFINET |
| PMP51B-AABACBH6AA3HFA1VXJA1 | 4…20 mA HART, 40 bar, G½ thread, aluminum, display |
Key Technical Features for SEO Content
1. Ceramic Capacitive Measuring Cell (Ceraphire®)
The PMP51B’s capacitive ceramic sensor offers distinct advantages over conventional piezoresistive designs:-25
Vacuum-resistant — withstands full vacuum down to 50 mbar absolute without damage-2
Oil-free operation — no fill oil required for most measuring ranges, eliminating thermal drift and reducing maintenance
High overload resistance — withstands up to 600 bar overpressure (9,000 psi)-2
Chemical resistance — 99.9% pure Al₂O₃ ceramic is highly resistant to corrosive and abrasive media-25
Integrated membrane breakage detection — ensures process safety and prevents media migration-25
2. Integrated Diagnostics (HistoROM®)
The PMP51B incorporates advanced diagnostic capabilities:
Automatic sensor health check
Diaphragm rupture detection (critical for safety applications)
Logs process and device events (up to 1,000 entries)
Undervoltage detection prevents dangerous plant conditions and frozen current values-4
- Flexible Communication Options
All E&H PMP51B pressure transmitter variants support multiple communication protocols:-2
4…20 mA analog — legacy compatibility
4…20 mA HART (version 7) — standard for most applications
PROFINET with Ethernet-APL — digital integration for Industry 4.0
Bluetooth® (SmartBlue App) — wireless remote configuration, commissioning, and proof testing from mobile devices without process interruption-2
HART protocol-specific data: Manufacturer ID 17 (0x11 hex), Device Type ID 0x112A, HART specification 7, minimum load resistance 250 Ω. Supported functions include burst mode, additional transmitter status, device locking, and multidrop operation.-82
4. FLEX Selection Concept
Endress+Hauser offers four product tiers to match application requirements:-1
| Tier | Description |
| Fundamental | Meet your basic measurement needs |
| Lean | Handle core processes easily |
| Extended | Optimize with innovative technologies |
| Xpert | Master challenging applications |
5. SIL 2/3 Capability
Models with suffix JA2 (rather than JA1) are TÜV-certified for safety instrumented systems — SIL 2 for single-channel use, SIL 3 for redundant (1oo2) architecture. Development complies with IEC 61508 for enhanced safety.-4
6. HART Output Technical Details
The 4…20 mA HART output offers three selectable operating modes:-82
4.0 … 20.5 mA (standard)
NAMUR NE 43: 3.8 … 20.5 mA (factory setting)
US mode: 3.9 … 20.8 mA
Signal on alarm follows NAMUR NE 43 with options: max alarm (21.5 … 23 mA) or min alarm (<3.6 mA). Damping is adjustable (factory setting: 1 second) and affects both output signal and display.-82
Application-Specific Recommendations
| Application | Recommended Model | Key Parameter |
| High-pressure hydraulic systems | PMP51B-AAAAABB8AA3HAAAAAJA1 | 400 bar, G½ thread, aluminum housing |
| Low-pressure air/gas monitoring | PMP51B-AAAAAAB9AA3HAAAAAJA1 | 100 mbar, ceramic cell, no display |
| Hazardous area (Zone 0/1) | PMP51B-AA1AAAB8AA3HAAAAAJA1 | 400 bar, Ex ia approval, ATEX/IECEx |
| Chemical reactor (aggressive media) | PMP51B-CC2AAB9AA3HAAAAAJA1 | 100 mbar, Hastelloy wetted parts |
| Food & dairy (CIP/SIP) | PMP51B-BB1AABB9CA3HAAA1AJA1 | Tri-Clamp connection, 316L housing |
| Offshore / marine corrosive environment | PMP51B-AAAAABB8AA3HKA2AJA1 | IP69K, 316L housing, M20 entry |
| Safety instrumented system (SIL) | PMP51B-AAAAABB8AA3HAAAAAJA2 | SIL 2/3 certification, 5-point calibration |
| PROFINET / Industry 4.0 integration | PMP51B-AAAACBH8BD3FAA2VJJG4 | PROFINET with Ethernet-APL, 316L housing |
| Steam / high-temperature process | PMP51B-CCBADBH6BD3KFA2VJJG2 | High-temperature fill fluid, diaphragm seal |
Field of application: The Cerabar PMP51B measures both absolute and gauge pressure accurately and reliably. The choice between metallic and ceramic sensor allows users to select the optimal transmitter for their specific process. Extended applications are enabled by measuring ranges from 5 mbar to 420 bar and process temperatures from -70°C to +400°C.-4
Comparison with Competing Technologies
The E&H PMP51B pressure transmitter competes with products from Emerson (Rosemount), Yokogawa, and Siemens in the global pressure transmitter market.-
| Feature | E&H PMP51B (Ceramic) | Rosemount 3051S (Silicon) | Yokogawa EJA-E (DPharp) |
| Sensing technology | Capacitive ceramic | Resonant silicon | Digital silicon resonant |
| Standard accuracy | 0.075% | 0.04% | 0.04% |
| Platinum accuracy | 0.055% | 0.025% | 0.04% |
| Turn down ratio | 100:1 | 200:1 | 200:1 |
| Vacuum capability | Excellent (ceramic) | Requires fill fluid | Requires fill fluid |
| Chemical resistance | Excellent (ceramic) | Moderate | Moderate |
| Bluetooth wireless | Yes (optional) | Limited | Limited |
| SIL certification | SIL 2/3 | SIL 2/3 | SIL 2 |
PMP51B advantage: The oil-free ceramic sensor provides superior performance in vacuum applications and with corrosive/abrasive media — scenarios where silicon-based sensors with fill fluids may fail due to diaphragm rupture or fluid migration.-25
Installation & Commissioning
Mounting
The PMP51B can be installed via:
Direct thread connection — G½ … G2, R½, MNPT¾ … MNPT2, FNPT½
Flange mounting — DIN, ASME, JIS (DN25 … DN80, NPS 1″ … 3″)-2
Hygienic connections — Tri-Clamp, DIN11851, DIN11864-1, NEUMO, Varivent, SMS, DRD-46
Endress+Hauser offers mounting brackets for pipe or wall installation. Flushing rings, flange seals, and pancake seals are recommended when buildup or clogging is expected at the membrane.-
Electrical Connection
M20x1.5 cable gland (standard for PMP51B-AAAAABB8AA3HAAAAAJA1)
Alternative entries available through ordering code modifications
Commissioning
Local operation: Optional LCD display with intuitive wizard navigation
Remote operation: SmartBlue App via secure Bluetooth connection
Digital integration: DeviceCare or FieldCare software for PC-based configuration
The software includes integrated digital assistants for fast, error-free commissioning, device locking, and easy measuring point documentation.-4
Certifications & Compliance
The E&H PMP51B pressure transmitter carries a comprehensive suite of international certifications:
| Category | Certifications |
| Explosion protection | ATEX, IECEx, CSA C/US, NEPSI, INMETRO, UK Ex-2-7 |
| Functional safety | SIL 2 / SIL 3 (IEC 61508)-2 |
| Hygienic | 3A, EHEDG, CoC ASME-BPE-46 |
| Marine | GL, ABS, LR, BV, DNV-46 |
| Drinking water | NSF-2 |
| Material / Design | EN 10204-3.1, NACE MR0175, NACE MR0103-2 |
| General | EAC, FM |