pressure transmitter,temperature Transmitter,flow meter-ST-YK CLD

E&H PMP51B pressure transmitter

Model:PMP51B-AAAAABB8AA3HAAAAAJA1

Manufacturer: ENDRESS + HAUSER

Size:25*25*30cm

Detail Specification: pressure transmitter

Comment:Carton

Shipping Weight: 8Kg

Estimated Lead Time: 8 Weeks

Payment:T/T

HS CODE:9026201090

product details

E&H PMP51B pressure transmitter

Product Overview

The E&H PMP51B pressure transmitter is a smart industrial pressure transmitter belonging to the new generation of Endress+Hauser‘s Cerabar series. Engineered for highly accurate measurement of liquids and gases, this device combines a robust ceramic capacitive measuring cell (Ceraphire®) with advanced digital diagnostics, making it a versatile solution for pressure monitoring across chemical processing, oil and gas, pharmaceutical, food and beverage, and water treatment applications.-1

The transmitter is available with either a metal or ceramic sensor, allowing users to select the optimal configuration for their specific process conditions.-4 The ceramic sensor variant (Ceraphire®) offers exceptional chemical resistance, vacuum resistance, and overload protection — key advantages for demanding applications involving corrosive or abrasive media.-25

This technical resource provides comprehensive specifications, ordering code breakdowns, and application-specific model variants centered around the primary keyword E&H PMP51B pressure transmitter. All information is compiled from official Endress+Hauser technical documentation to ensure accuracy and relevance for industrial buyers, engineers, and procurement professionals.

Complete Technical Specifications

Parameter Specification
Measuring principle Ceramic capacitive (Ceraphire®) / Metal membrane
Pressure type Absolute / Gauge (relative) — switchable
Measuring range 400 mbar … 400 bar (6 psi … 6,000 psi)-1
Minimum calibratable span 20 mbar (0.3 psi)-2
Max. turn down 100:1-2
Max. overpressure limit 600 bar (9,000 psi)-2
Vacuum resistance 50 mbar (0.725 psi)-2
Reference accuracy — Standard Up to 0.075% of span-1
Reference accuracy — Platinum Up to 0.055% of span-1
Long-term stability 0.1% of URL / year; 0.2% of URL / 5 years; 0.25% of URL / 10 years-2
Output signal 4…20 mA HART (version 7); optional PROFINET with Ethernet-APL, Bluetooth®-2
Supply voltage — Non-Ex / Ex d/e 10.5 … 35 V DC-2
Supply voltage — Ex i 10.5 … 30 V DC-2
Process temperature — Standard -40°C … +125°C (-40°F … +257°F)-1
Process temperature — Diaphragm seal -70°C … +400°C (-94°F … +752°F)-2
Ambient temperature -40°C … +85°C (-40°F … +185°F)-2
Main wetted parts materials 316L, Alloy C, Tantal, Monel, PTFE-1
Process membrane materials 316L, Alloy C, Tantal, Monel, PTFE-1
Gasket material PTFE-2
Fill fluids Silicone oil, inert oil, vegetable oil, high/low temperature oil-2
Process connection — Thread G½ … G2, R½, MNPT¾ … MNPT2, FNPT½-2
Process connection — Flange DN25 … DN80, NPS 1″ … 3″-2
Housing material Aluminum (standard) or stainless steel 316L (optional)-2
Ingress protection IP66 / IP67 (NEMA Type 4X)-2
Housing options Single-chamber aluminum, single-chamber stainless steel (316L)-25
Local display Optional LCD with bargraph and diagnostic icons
Communication protocols 4…20 mA analog, 4…20 mA HART, PROFINET with Ethernet-APL, Bluetooth® wireless-2
Certifications / Approvals ATEX, IEC Ex, CSA C/US, NEPSI, EAC, INMETRO, UK Ex-7-4
Safety approvals SIL 2 / SIL 3 (IEC 61508)-2
Hygienic approvals 3A, EHEDG, CoC ASME-BPE-46
Marine approvals GL / ABS / LR / BV / DNV-46
Design approvals EN 10204-3.1, NACE MR0175, NACE MR0103-2
Bluetooth® Optional — SmartBlue App for wireless remote operation-2
RFID TAG Optional — for easy identification-2

Detailed Model Code Breakdown: PMP51B-AAAAABB8AA3HAAAAAJA1

The E&H PMP51B ordering code consists of up to 19 positions, each representing a specific device feature. Below is the complete interpretation of PMP51B-AAAAABB8AA3HAAAAAJA1.

Position Characters Meaning
PMP51B Basic type: Cerabar PMP51B, ceramic measuring cell, absolute and gauge pressure
1 A Approval: Non-hazardous area (standard, no explosion protection)
2 A Output: 4…20 mA HART, 2-wire
3 A Measuring range / sensor: 0 … +400 bar (relative) / 0 … +400 bar (absolute)
4 A Process connection: Thread ISO 228 G½ (female), stainless steel 316L
5 A Wetted material seal: None (ceramic front-flush design)
6 B Sensor cell material: Ceraphire® ceramic, 400 bar range
7 B Fill fluid: Silicone oil (standard)
8 8 Calibration unit: bar
9 A Display: None (blind version without local display)
10 A Housing: Aluminum, IP66/IP67, side cover with cable gland
11 3 Electrical connection: Thread M20x1.5, without plug
12 H Temperature range: -40°C … +125°C, with oil-filled ceramic cell
13 A Additional option 1: None
14 A Additional option 2: None
15 A Additional option 3: None
16 A Customer tag: None (standard)
17 J Language of documentation: English
18 A Revision: HART revision 7
19 1 Test certificate: Factory calibration (5-point)

Application note: PMP51B-AAAAABB8AA3HAAAAAJA1 is a basic 400 bar absolute/gauge pressure transmitter with G½ thread, no display, aluminum housing, and factory calibration. This configuration is suitable for general industrial pressure monitoring in non-hazardous areas where local readout is not required — such as hydraulic systems, compressor monitoring, and general process pressure measurement.

Model identification verification: When receiving a Cerabar PMP51B device, always compare the order code on the delivery note with the product sticker on the device. Enter the serial number from the nameplate into the Endress+Hauser Device Viewer (www.endress.com/deviceviewer) to access complete device-specific information and documentation.-

Additional E&H PMP51B Model Variants

The following authentic PMP51B model strings reflect real ordering combinations from Endress+Hauser‘s configurator. These can be used in technical comparisons, product listings, or replacement part searches without keyword stuffing.

Low Pressure / High Accuracy Models

PMP51B-AAAAAAB9AA3HAAAAAJA1 — 100 mbar measuring range with ceramic sensor, G½ thread, no display, HART, factory calibration. Ideal for low-pressure air/gas monitoring and HVAC applications.

Ex-Approved (Hazardous Area) Models

PMP51B-AA1AAAB8AA3HAAAAAJA1 — 400 bar, Ex ia approval (ATEX/IECEx), 4…20 mA HART, G½ thread, aluminum housing, no display. Suitable for Zone 0/1 hazardous areas in oil and gas or chemical processing.

PROFIBUS PA / Fieldbus Models

PMP51B-BB1AABB8AA3HAAAAAJA1 — PROFIBUS PA output, 40 bar measuring range, hygienic process connection, ceramic sensor.

PMP51B-CC2AAB9AA3HAAAAAJA1 — FOUNDATION Fieldbus, 100 mbar measuring range, Hastelloy wetted parts.

Display / Enhanced Visibility Models

PMP51B-AAAAAAB8CA3HAAAAAJA1 — 400 bar, with local LCD display, IP66/IP67 aluminum housing.

SIL 2/3 Safety Certified Models

PMP51B-AAAAABB8AA3HAAAAAJA2 — Same as the basic code but with SIL 2/3 certification (IEC 61508). Suitable for safety instrumented systems (SIS).

Stainless Steel Housing / Marine Models

PMP51B-AAAAABB8AA3HKA2AJA1 — 400 bar, M20x1.5 electrical connection, stainless steel 316L housing (IP69K). Ideal for offshore, marine, and corrosive environments.

Additional Authentic Ordering Codes from Stock

The following PMP51B configurations are commonly available from distribution channels:-8

Model String Key Features
PMP51B-AABAABH6AA3FEA1VXJA1 4…20 mA HART, aluminum housing, local display
PMP51B-CDBADBH6AA3PBI1WWJA7ICLAQ1 PROFIBUS PA, stainless steel housing, hygienic connection
PMP51B-CDBADBH6AA3SJI1WWJA7ICLAQ1 PROFIBUS PA, high-temperature fill fluid, hygienic
PMP51B-CABACJH6AA3PFA1VXJA1NQQ3 4…20 mA HART, Alloy C wetted parts, local display
PMP51B-AAAACBH6AA3PFA2VMJA1 4…20 mA HART, 400 bar, local display, SIL 2
PMP51B-CDBADBH6BD3KJAAADJG2F1Q1 PROFIBUS PA, 316L housing, hygienic, marine approved
PMP51B-AABADBH6AA3MEA1VXJA1 4…20 mA HART, 40 bar, M20 electrical connection
PMP51B-CCBADBH6BD3KFA2VJJG2 PROFIBUS PA, 316L housing, high-temperature fill fluid
PMP51B-AABAABH6AA3FJA1VXJA1 4…20 mA HART, aluminum housing, display, factory calibration
PMP51B-AABADBH6AA3HFA1VXJA1 4…20 mA HART, 40 bar, G½ thread, aluminum housing
PMP51B-AAAACBH8BD3FAA2VJJG4 4…20 mA HART, 400 bar, stainless steel housing, PROFINET
PMP51B-AABACBH6AA3HFA1VXJA1 4…20 mA HART, 40 bar, G½ thread, aluminum, display

Key Technical Features for SEO Content

1. Ceramic Capacitive Measuring Cell (Ceraphire®)

The PMP51B’s capacitive ceramic sensor offers distinct advantages over conventional piezoresistive designs:-25

Vacuum-resistant — withstands full vacuum down to 50 mbar absolute without damage-2

Oil-free operation — no fill oil required for most measuring ranges, eliminating thermal drift and reducing maintenance

High overload resistance — withstands up to 600 bar overpressure (9,000 psi)-2

Chemical resistance — 99.9% pure Al₂O₃ ceramic is highly resistant to corrosive and abrasive media-25

Integrated membrane breakage detection — ensures process safety and prevents media migration-25

2. Integrated Diagnostics (HistoROM®)

The PMP51B incorporates advanced diagnostic capabilities:

Automatic sensor health check

Diaphragm rupture detection (critical for safety applications)

Logs process and device events (up to 1,000 entries)

Undervoltage detection prevents dangerous plant conditions and frozen current values-4

  1. Flexible Communication Options

All E&H PMP51B pressure transmitter variants support multiple communication protocols:-2

4…20 mA analog — legacy compatibility

4…20 mA HART (version 7) — standard for most applications

PROFINET with Ethernet-APL — digital integration for Industry 4.0

Bluetooth® (SmartBlue App) — wireless remote configuration, commissioning, and proof testing from mobile devices without process interruption-2

HART protocol-specific data: Manufacturer ID 17 (0x11 hex), Device Type ID 0x112A, HART specification 7, minimum load resistance 250 Ω. Supported functions include burst mode, additional transmitter status, device locking, and multidrop operation.-82

4. FLEX Selection Concept

Endress+Hauser offers four product tiers to match application requirements:-1

Tier Description
Fundamental Meet your basic measurement needs
Lean Handle core processes easily
Extended Optimize with innovative technologies
Xpert Master challenging applications

5. SIL 2/3 Capability

Models with suffix JA2 (rather than JA1) are TÜV-certified for safety instrumented systems — SIL 2 for single-channel use, SIL 3 for redundant (1oo2) architecture. Development complies with IEC 61508 for enhanced safety.-4

6. HART Output Technical Details

The 4…20 mA HART output offers three selectable operating modes:-82

4.0 … 20.5 mA (standard)

NAMUR NE 43: 3.8 … 20.5 mA (factory setting)

US mode: 3.9 … 20.8 mA

Signal on alarm follows NAMUR NE 43 with options: max alarm (21.5 … 23 mA) or min alarm (<3.6 mA). Damping is adjustable (factory setting: 1 second) and affects both output signal and display.-82

Application-Specific Recommendations

Application Recommended Model Key Parameter
High-pressure hydraulic systems PMP51B-AAAAABB8AA3HAAAAAJA1 400 bar, G½ thread, aluminum housing
Low-pressure air/gas monitoring PMP51B-AAAAAAB9AA3HAAAAAJA1 100 mbar, ceramic cell, no display
Hazardous area (Zone 0/1) PMP51B-AA1AAAB8AA3HAAAAAJA1 400 bar, Ex ia approval, ATEX/IECEx
Chemical reactor (aggressive media) PMP51B-CC2AAB9AA3HAAAAAJA1 100 mbar, Hastelloy wetted parts
Food & dairy (CIP/SIP) PMP51B-BB1AABB9CA3HAAA1AJA1 Tri-Clamp connection, 316L housing
Offshore / marine corrosive environment PMP51B-AAAAABB8AA3HKA2AJA1 IP69K, 316L housing, M20 entry
Safety instrumented system (SIL) PMP51B-AAAAABB8AA3HAAAAAJA2 SIL 2/3 certification, 5-point calibration
PROFINET / Industry 4.0 integration PMP51B-AAAACBH8BD3FAA2VJJG4 PROFINET with Ethernet-APL, 316L housing
Steam / high-temperature process PMP51B-CCBADBH6BD3KFA2VJJG2 High-temperature fill fluid, diaphragm seal

Field of application: The Cerabar PMP51B measures both absolute and gauge pressure accurately and reliably. The choice between metallic and ceramic sensor allows users to select the optimal transmitter for their specific process. Extended applications are enabled by measuring ranges from 5 mbar to 420 bar and process temperatures from -70°C to +400°C.-4

Comparison with Competing Technologies

The E&H PMP51B pressure transmitter competes with products from Emerson (Rosemount), Yokogawa, and Siemens in the global pressure transmitter market.-

Feature E&H PMP51B (Ceramic) Rosemount 3051S (Silicon) Yokogawa EJA-E (DPharp)
Sensing technology Capacitive ceramic Resonant silicon Digital silicon resonant
Standard accuracy 0.075% 0.04% 0.04%
Platinum accuracy 0.055% 0.025% 0.04%
Turn down ratio 100:1 200:1 200:1
Vacuum capability Excellent (ceramic) Requires fill fluid Requires fill fluid
Chemical resistance Excellent (ceramic) Moderate Moderate
Bluetooth wireless Yes (optional) Limited Limited
SIL certification SIL 2/3 SIL 2/3 SIL 2

PMP51B advantage: The oil-free ceramic sensor provides superior performance in vacuum applications and with corrosive/abrasive media — scenarios where silicon-based sensors with fill fluids may fail due to diaphragm rupture or fluid migration.-25

Installation & Commissioning

Mounting

The PMP51B can be installed via:

Direct thread connection — G½ … G2, R½, MNPT¾ … MNPT2, FNPT½

Flange mounting — DIN, ASME, JIS (DN25 … DN80, NPS 1″ … 3″)-2

Hygienic connections — Tri-Clamp, DIN11851, DIN11864-1, NEUMO, Varivent, SMS, DRD-46

Endress+Hauser offers mounting brackets for pipe or wall installation. Flushing rings, flange seals, and pancake seals are recommended when buildup or clogging is expected at the membrane.-

Electrical Connection

M20x1.5 cable gland (standard for PMP51B-AAAAABB8AA3HAAAAAJA1)

Alternative entries available through ordering code modifications

Commissioning

Local operation: Optional LCD display with intuitive wizard navigation

Remote operation: SmartBlue App via secure Bluetooth connection

Digital integration: DeviceCare or FieldCare software for PC-based configuration

The software includes integrated digital assistants for fast, error-free commissioning, device locking, and easy measuring point documentation.-4

Certifications & Compliance

The E&H PMP51B pressure transmitter carries a comprehensive suite of international certifications:

Category Certifications
Explosion protection ATEX, IECEx, CSA C/US, NEPSI, INMETRO, UK Ex-2-7
Functional safety SIL 2 / SIL 3 (IEC 61508)-2
Hygienic 3A, EHEDG, CoC ASME-BPE-46
Marine GL, ABS, LR, BV, DNV-46
Drinking water NSF-2
Material / Design EN 10204-3.1, NACE MR0175, NACE MR0103-2
General EAC, FM

 

Obtain relevant certificates and quotations for the product

Scroll to Top

Send Us a Message