pressure transmitter,temperature Transmitter,flow meter-ST-YK CLD

Emerson Rosemount 3051SFA Flow Meter

Model:3051SFADL120DCHPS2T100032AA1B2RHM5

Manufacturer: ROSEMOUNT

Size: 40*80*25CM

Detail Specification: Annubar Flow Meter

Comment:Carton

Shipping Weight: 20Kg

Estimated Lead Time: 12 Weeks

Payment:T/T

HS CODE:9026809000

product details

Emerson Rosemount 3051SFA Flow Meter

Product Overview

The Rosemount 3051SFA Annubar Flow Meter integrates a patented averaging pitot tube with advanced multivariable transmitter technology into a single, unified flow measurement solution-1. Designed for gas, liquid, and steam applications across line sizes from 2 to 96 inches (50 to 2440 mm), this device measures differential pressure, static pressure, and process temperature simultaneously while calculating fully compensated mass flow 22 times per second within the transmitter-1-3.

Key Technical Specifications

Parameter Specification
Line Size Range 2 to 96 in. (50 to 2440 mm)-3
DP Measurement Range Up to 1000 inH₂O (2.48 bar)-3
Static Pressure Range Up to 3626 psia / psig (250 bar)-3
Flow Turndown 200:1 rangedown (14:1 flow turndown)-3
Ultra for Flow Accuracy ±0.04% of reading-3
Process Wetted Materials 316 SST, Alloy C-276-3
Communication Protocols 4-20 mA HART, WirelessHART, FOUNDATION Fieldbus-3
Diagnostics Loop Integrity, Process Intelligence, Plugged Impulse Line-3
SIL Certification SIL 2/3 to IEC 61508-3
Warranty Up to 15 years limited-3

Model Number Breakdown: 3051SFADL120DCHPS2T100032AA1B2RHM5

Every Rosemount 3051SFA is defined by its complete model number string. The following breakdown explains each segment of 3051SFADL120DCHPS2T100032AA1B2RHM5:

Position Characters Field Description
1–8 3051SFA D Product Type + Measurement Type D = Compensated Mass & Energy Flow Calculations (DP + SP + Temperature)-11-13
9–11 L12 Line Size / Pipe Size L12 = 12-inch (300 mm) pipe-13
12 0 Line Size Modifier 0 = Standard configuration
13–14 DC Sensor Material DC = 316 SST sensor construction-11
15 H Process Connection H = Flanged (wafer style)
16–17 PS Probe Style PS = Standard insertion probe
18 2 Probe Length 2 = Standard probe length
19 T1 Thermal Well T1 = Integral thermowell for temperature measurement-11
20 0 O-Ring Material 0 = Standard O-ring
21–22 00 Calibration 00 = Factory standard calibration
23 0 Zero/Span Adjustment 0 = No external adjustment
24–25 32 Mounting Hardware 32 = Standard mounting hardware
26–28 AA1 Housing Configuration AA1 = Aluminum housing, standard electronics-11
29–30 B2 Output Protocol B2 = 4-20 mA with HART 7-11
31 R Hazardous Location Approval R = ATEX flameproof approval
32–33 HM Additional Options HM = High-temp option and material certification
34 5 Calibration Certificate 5 = NIST traceable calibration certificate

This configuration represents a fully compensated mass flow meter for a 12-inch pipe, equipped with 316 SST sensor material, integral thermowell, HART output, and hazardous location approval-11.

Additional 3051SFA Model Examples

Complete model numbers vary by line size, measurement type, and options. Common configurations include:

3051SFADL020DC — For 2-inch lines with fully compensated mass flow calculation

3051SFA1L040DC — Differential pressure only, for 4-inch lines

3051SFA5L080DC — Compensated flow (DP + temperature), for 8-inch lines

3051SFA7L200DC — Process variables only, for 20-inch lines

3051SFA2G120DC and 3051SFA6G160DC represent gas-specific configurations for 12-inch and 16-inch pipelines, respectively-28.

T-Shaped Sensor Design

The patented T-shaped sensor is engineered with an integral thermowell, enabling temperature measurement without additional pipe penetrations-3. This single-penetration design reduces installation complexity and potential leak points while maintaining a small profile in the pipe to minimize permanent pressure loss-1. The stagnation zone is strategically positioned to reduce signal noise and prevent particulate accumulation-3.

Installation Guidelines

For liquid applications, proper orientation is essential to prevent air trapping. The Annubar sensor should be positioned at 45° from vertical down, allowing air to vent and preventing sediment collection within the sensor body-24. Remote-mount transmitter configurations require the transmitter to be positioned below the process piping, with impulse lines routed downward-24. For gas and steam applications, drain/vent ports should be positioned at the bottom to allow condensate drainage.

Ordering Information Reference

Measurement Type codes determine how the transmitter processes input variables:

Type D (as shown above): Fully compensated mass and energy flow calculations using differential pressure, static pressure, and process temperature-13

Types 1-3: Differential pressure with various compensation combinations

Types 4-7: Process variable outputs without internal flow calculations

Sensor stagnation zone design reduces noise and keeps particulates from clogging, contributing to long-term measurement stability

 

Obtain relevant certificates and quotations for the product

Scroll to Top

Send Us a Message