Emerson Rosemount 8721 Hygienic Magnetic Flow Meter Sensor
| Model:8721ASA020RA2Q4 Manufacturer: ROSEMOUNT Size: 40*80*25CM Detail Specification: Annubar Flow Meter Comment:Carton Shipping Weight: 20Kg Estimated Lead Time: 12 Weeks Payment:T/T HS CODE:9026809000
|
product details
Emerson Rosemount 8721 Hygienic Magnetic Flow Meter Sensor
Introduction
In hygienic processing industries—food and beverage, dairy, pharmaceutical, and life sciences—accurate and sanitary flow measurement is not optional. It is a regulatory and operational necessity. The Emerson Rosemount 8721 Hygienic Magnetic Flow Meter Sensor represents the industry benchmark for these demanding applications, combining high-precision electromagnetic flow technology with a fully welded, obstructionless design that meets the most stringent sanitary standards. This technical datasheet provides comprehensive specifications, performance data, and application guidance for engineering professionals seeking reliable flow measurement solutions.
What Is the Rosemount 8721 Hygienic Magnetic Flow Meter Sensor?
The Rosemount 8721 is a hygienic magnetic flowtube sensor designed specifically for conductive liquid flow measurement in sanitary environments. Unlike traditional differential pressure flow meters such as the Rosemount Annubar averaging pitot tube—which relies on pressure differential created by a sensor inserted into the flow stream—the 8721 sensor uses Faraday’s Law of Electromagnetic Induction. This non-intrusive measurement principle eliminates moving parts and flow obstructions, providing maintenance-free operation ideal for CIP (Clean-In-Place) and SIP (Sterilize-In-Place) environments.
The Emerson Rosemount 8721 Hygienic Magnetic Flow Meter Sensor system consists of two primary components: the 8721 flowtube sensor and a compatible transmitter, such as the Rosemount 8732E, 8742, or 8712D. Complete system configurations include model numbers such as 8721010 (½-inch sensor with M-8712E transmitter), 8721020 (2-inch sensor, DN50), 8721030 (3-inch sensor, DN80), and 8721040 (4-inch sensor) matched with M-8732E transmitters–.
Key Technical Specifications
Accuracy and Performance
The Rosemount 8721 achieves volumetric flow accuracy up to ±0.15% over 13:1 flow turndowns and ±0.25% over 40:1 flow turndown when paired with the appropriate transmitter-. For applications requiring lower precision, the sensor delivers 0.5% accuracy over 40:1 flow turndown-.
Flow Rate Capability
The 8721020 (2-inch) and all other sensor sizes process signals from conductive fluids traveling between 0.04 and 39 ft/s (0.01 to 12 m/s) for both forward and reverse flow directions-. The full-scale flow range is continuously adjustable between -33 and 33 ft/s (-10 to 10 m/s)-.
Line Sizes
The Rosemount 8721 hygienic magnetic flow meter sensor is available in line sizes from ½ inch (15 mm) to 4 inches (100 mm) in standard increments-. Each sensor is manufactured with internal diameters (ID) designed to seamlessly match hygienic process tube IDs, eliminating step changes that could trap process media.
Wetted Materials
Lining Material: PFA (perfluoroalkoxy) — Chemically inert and FDA-approved for food contact-
Electrode Materials: 316L stainless steel (standard), Nickel Alloy (Hastelloy C-22), Platinum (for aggressive or high-purity applications)-
Sensor Body: Fully welded 316L stainless steel construction
Process and Environmental Conditions
Process Temperature Range (PFA Lining): 14 to 320°F (-10 to 160°C)-
Ambient Temperature Range: 14 to 140°F (-15 to 60°C)-
Vacuum Rating: Maintains full vacuum up to the maximum material temperature limit-
Submersion Protection: IP68 rating up to 30 feet (10 meters)-
Hygienic Certifications and Compliance
The Emerson Rosemount 8721 Hygienic Magnetic Flow Meter Sensor is manufactured with FDA-approved contact surfaces and carries 3-A Sanitary Standard certification (Certificate #1222) and EHEDG certification (Certificate #C03-5229) , approved for use in Grade A milk service (M-b 350)-. The fully welded meter body eliminates crevices where bacteria could accumulate, ensuring compliance with global food safety protocols including HACCP.
Comparison: Rosemount 8721 vs. Rosemount Annubar
When selecting flow measurement technology for hygienic applications, understanding the distinction between these two Emerson Rosemount platforms is critical:
| Specification | Rosemount 8721 (Magnetic) | Rosemount Annubar (DP) |
| Operating Principle | Electromagnetic induction | Averaging pitot tube (differential pressure) |
| Flow Obstruction | None (full bore) | Minimal (T-shaped sensor in flow stream) |
| Moving Parts | None | None |
| Media Suitability | Conductive liquids only | Gases, steam, and liquids |
| Hygienic Suitability | Excellent (3-A, EHEDG certified) | Not recommended for hygienic service |
| Accuracy | ±0.15–0.5% of volumetric flow rate | Typically 0.75–1.5% of flow rate |
| Pressure Drop | Negligible (full bore) | Very low (lower than orifice plates) |
The Annubar averaging pitot tube—represented by models such as the Rosemount 485 Annubar and 585 Annubar primary elements—is optimized for gas, steam, and liquid applications in power, oil & gas, and chemical processing. However, the Rosemount 485 Annubar and 585 Annubar sensors are not recommended for hygienic food or pharmaceutical service due to potential product entrapment concerns-. The Rosemount 8721 series is purpose-built for hygienic environments where smooth, crevice-free surfaces and full-bore design are mandatory.
Advanced Features
Diagnostics Suite
The Rosemount 8721 system offers comprehensive diagnostic capabilities when paired with 8732E or 8742 transmitters: In Situ Meter Verification, Grounding & Wiring Fault Detection, High Process Noise Detection, Tunable Empty Pipe Detection, Transmitter Fault Detection, and Sensor Fault Detection-. These diagnostics enable predictive maintenance and reduce unplanned downtime.
Transmitter Compatibility
The 8721 sensor is fully interchangeable with Rosemount 8732E, 8742, and 8712D transmitters. This modular design simplifies spare parts management and allows field upgrades without sensor replacement. The system supports HART and Fieldbus communication protocols with through-the-glass local operator interface for hazardous area operation.
Installation Advantages
The lightweight, compact stainless steel design simplifies installation in tight process skids. The Rosemount 8721030 (3-inch) sensor, for example, can be installed between existing hygienic ferrules using standard tri-clamp, IDF, or RJT process connections-. No straight-run requirements are needed upstream or downstream due to the obstructionless measurement principle.
Application Engineering Guidelines
Conductivity Requirement: The process fluid must have a minimum conductivity of 5 microsiemens per centimeter (µS/cm) for accurate measurement. Most water-based solutions, juices, dairy products, beers, syrups, and pharmaceutical solutions meet this requirement.
Grounding: Proper grounding is essential for electromagnetic flow meter operation. The Rosemount 8721 sensor includes grounding electrodes; however, additional grounding rings may be required for lined pipes.
Full-Pipe Condition: Like all magnetic flow meters, the 8721 requires full-pipe operating conditions for accurate measurement. Empty pipe detection diagnostics alert operators to partially filled conditions.
Ordering Information
The Emerson Rosemount 8721 Hygienic Magnetic Flow Meter Sensor is available in the following standardized configurations:
8721010: ½-inch (15 mm) sensor with M-8712E transmitter
8721020: 2-inch (50 mm) sensor with M-8732E transmitter-
8721030: 3-inch (80 mm) sensor with M-8732E transmitter-
8721040: 4-inch (100 mm) sensor with M-8732E transmitter
Each configuration is available with optional electrode materials (316L stainless steel, Nickel Alloy, or Platinum) and custom process connections. Consult the factory for pricing and lead times