pressure transmitter,temperature Transmitter,flow meter-ST-YK CLD

Honeywell PX2 Pressure Transducers

Model:PX2AN1XX200PAAAX

Manufacturer: Honeywell

Size: 10*10*10cm

Detail Specification: LCD

Comment:Carton

Shipping Weight: 0.5Kg

Estimated Lead Time: 4 Weeks

Payment:T/T

HS CODE:9026809000

 

product details

Honeywell PX2 Pressure Transducers

Overview

The Honeywell PX2 Series Heavy Duty Pressure Transmitter is a family of highly configurable industrial pressure transducers designed for reliable performance in demanding applications. Using piezoresistive sensing technology with an on-board ASIC for signal conditioning, the PX2 Series is housed in a rugged 304 stainless steel enclosure and delivers fully calibrated, temperature-compensated output across a wide operating range.

Unlike traditional process transmitters that integrate local display modules, the PX2 Series is a compact transducer form factor optimized for OEM and machinery integration where space is constrained and remote monitoring via control systems is preferred. For applications requiring local visual indication, external panel meters or loop-powered LCD displays can be integrated into the 4–20 mA loop.

The PX2 Series measures absolute, sealed gage, or vented gage pressure, with thousands of possible configurations allowing Honeywell to meet diverse customer requirements with short lead times-1. The series is available in three pressure ranges covering 1 bar to 70 bar, 100 kPa to 7 MPa, or 15 psi to 1000 psi-1. All products are RoHS compliant and manufactured according to ISO 9001 standards-1.

Key Specifications

General Specifications

Parameter Value
Product Type Heavy Duty Pressure Transducer (Transmitter)
Pressure Types Absolute, Sealed Gage, Vented Gage
Pressure Ranges 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi
Overpressure Rating Up to 2× FS (depending on range)
Burst Pressure Up to 5× FS (depending on range)
Total Error Band (TEB) ±2 %FSS over −40 °C to 125 °C
Accuracy ±0.25% Full Scale (typical for most models)
Output Signal Options 4–20 mA (2-wire loop-powered) | 0.5–4.5 V ratiometric | 1–5 V | 0–10 V (depending on model)
Supply Voltage 4.75–5.25 Vdc (ratiometric voltage models) | 8–30 Vdc (current output models)
Supply Current 5 mA (typical, voltage output)
Response Time < 2 ms (10–90% step change)
Warm-up Time < 100 ms (to within 1% of final value)
Pressure Cycles Durability ≥ 10 million cycles

Performance & Accuracy

Parameter Value
Reference Accuracy ±0.25% FSS (standard); ±0.5% FSS (economy models)
Total Error Band ±2% FSS over −40 °C to +125 °C
Long-term Stability ±0.25% FSS per year (typical)
Hysteresis ±0.1% FSS typical
Non-linearity (BFSL) ±0.1% FSS typical
Repeatability ±0.1% FSS typical

Total Error Band (TEB) Clarification

The PX2 Series is fully calibrated and compensated for offset, sensitivity, temperature effects and non-linearity using the on-board ASIC. This provides a Total Error Band of ±2% over the entire operating temperature range of −40 °C to 125 °C, meaning users can rely on consistent measurement accuracy without performing additional in-system calibration across the full temperature spectrum-1.

Temperature Specifications

Parameter Value
Operating Temperature Range −40 °C to +125 °C (−40 °F to +257 °F)
Compensated Temperature Range −40 °C to +125 °C
Storage Temperature −40 °C to +125 °C
Media Temperature Range −40 °C to +125 °C (compatible with measured media)
Temperature Effect on Zero ±0.02% FSS / °C typical
Temperature Effect on Span ±0.02% FSS / °C typical

Electrical Specifications

Parameter Value
Output Types Available 4–20 mA (2-wire loop-powered), 0.5–4.5 V ratiometric, 1–5 V regulated, 0–10 V
Supply Voltage (4–20 mA models) 8–30 Vdc (unregulated)
Supply Voltage (0.5–4.5 V ratiometric) 4.75–5.25 Vdc (regulated)
Supply Voltage (1–5 V regulated) 8–30 Vdc
Supply Voltage (0–10 V regulated) 12–30 Vdc
Output Load Resistance (4–20 mA) 0–500 Ω @ 24 Vdc
Output Load Resistance (Voltage models) ≥ 5 kΩ
Reverse Polarity Protection Yes
Short Circuit Protection Yes (output to ground or supply)
Electromagnetic Compatibility 100 V/m radiated immunity
Electrical Connection Packard Metri-Pack 150, Deutsch DT04-3P, cable harness, or integral connector

Pressure Port Specifications

Parameter Value
Port Materials 304 Stainless Steel
Diaphragm Material 304 Stainless Steel
Fluid Path Materials 304 stainless steel, epoxy, alumina, glass, silicon
Port Thread Options 7/16-20 UNF 45° Flare Female (SAE J512), 7/16-20 UNF 45° Flare Male (SAE J513), 7/16-20 UNF 37° Flare Male (SAE J514), G1/4 (ISO 1179-3), G1/8 (ISO 1179-3), M12×1.5 (ISO 6149-3), 1/4-18 NPT, 1/8-27 NPT, 9/16-18 UNF (SAE J1926-3), 7/16-20 UNF (SAE J1926-3)

Environmental & Mechanical

Parameter Value
Ingress Protection Up to IP69K (dependent on configuration)
Housing Material 304 Stainless Steel
Weight Approx. 35–50 grams (depending on port and connector type)
Mechanical Shock 100 g / 6 ms (MIL-STD-202G, Method 213B)
Vibration 20 g / 10–2000 Hz (MIL-STD-202G, Method 214A)
Radiated Immunity 100 V/m (ISO 11452-2)
ESD Protection ±8 kV contact, ±15 kV air (IEC 61000-4-2)

Media Compatibility

The PX2 Series is compatible with a wide range of harsh media commonly found in industrial applications-1-18:

Media Category Examples
Refrigerants (HFC-based) R410A, R134A, R448A (Solstice® N40), R32, R1234ZE
Industrial Fluids Engine oil, petroleum-based hydraulic fluids, DOT 3 brake fluid
Other Media Dry air, compressed air, tap water

Note: For ammonia and other highly corrosive media, refer to Honeywell‘s SPT Series-18. The PX2 Series fluid path is an assembly of 304 stainless steel, epoxy, alumina, glass, and silicon; use only non-abrasive, chemically compatible media to prevent damage to diaphragm or port materials-25.

Certifications & Compliance

Certification Status
RoHS Compliant
ISO 9001 Designed and manufactured under certified quality system
CE Compliant
UKCA Compliant
REACH Compliant
FDA Food Contact Certain configurations (consult factory)

Pressure Reference Types

The PX2 Series supports three distinct pressure measurement references:

Reference Type Description
Absolute Measures pressure relative to a perfect vacuum (internal vacuum reference). Output is proportional to absolute pressure. Ideal for barometric pressure measurement, altitude sensing, and vacuum monitoring.
Sealed Gage Measures pressure relative to a fixed reference of one atmosphere at sea level. Suitable for applications where atmospheric pressure variation is not relevant, such as hydraulic systems and sealed vessels.
Vented Gage Measures pressure relative to ambient atmospheric pressure through a vent tube in the cable or port. Ideal for tank level measurement and applications requiring atmospheric compensation.

Output Signal Options

The PX2 Series offers multiple output configurations to accommodate different control system requirements:

Output Type Supply Voltage Output Range Application Suitability
4–20 mA (2-wire) 8–30 Vdc 4–20 mA Long-distance transmission, industrial PLCs, loop-powered systems
0.5–4.5 V (Ratiometric) 4.75–5.25 Vdc 0.5–4.5 V Microcontroller/ADC inputs, automotive, battery-powered systems
1–5 V (Regulated) 8–30 Vdc 1–5 V PLC analog inputs, industrial controls
0–10 V (Regulated) 12–30 Vdc 0–10 V Building automation, HVAC, general industrial

For applications requiring local visual indication with a 4–20 mA output, an external loop-powered LCD panel meter or digital indicator can be placed in series with the current loop to provide real-time pressure readout without affecting the 4–20 mA signal integrity.

Configuration Nomenclature

The PX2 Series ordering code follows a structured format that encodes pressure range, output type, pressure reference, port style, electrical connection, and other options. Standard configuration elements include:

Pressure Range: 006B (6 bar), 015P (15 psi), 030P (30 psi), 060P (60 psi), 100P (100 psi), 200P (200 psi), 300P (300 psi), 500P (500 psi), 1000P (1000 psi)

Output Type: AC (0.5–4.5 V ratiometric), AD (1–5 V regulated), AF (4–20 mA), AG (0–10 V)

Pressure Reference: A (Absolute), G (Vented Gage), S (Sealed Gage)

Port Style: Variants include NPT, UNF, G-thread, and M-thread options

Electrical Connection: Packard, Deutsch, cable, or custom harness

Example Configuration: PX2AN1XX200PAAAX = PX2 Series, Absolute pressure, 200 psi range, 0.5–4.5 V output, 1/4″ NPT male port, Packard connector, RoHS compliant.

Applications

The PX2 Series Heavy Duty Pressure Transmitter is engineered for monitoring performance and efficiency across a broad spectrum of industrial applications–18:

Industry Segment Specific Applications
HVAC / Refrigeration Refrigerant pressure monitoring, compressor discharge/suction pressure, chiller systems, heat pumps
Air Compressors Tank pressure monitoring, compressor control, system pressure indication
Industrial Machinery Hydraulic system pressure, pneumatic controls, press monitoring
Factory Automation Robotic pressure feedback, assembly line monitoring, leak testing
Valve & Pump Control Pump discharge pressure, valve position feedback, flow control systems
Packaging & Lamination Laminating roller pressure, packaging machine pneumatics
Spray Equipment Paint and coating spray pressure, foam dispensing systems
Solar & Emissions Monitoring Solar thermal system pressure, emissions control system monitoring
Transportation (Heavy Equipment) Brake system pressure, transmission pressure, hydraulic implement control
Laser Cooling Systems Coolant pressure monitoring for industrial laser systems

The PX2 Series can survive at least 10 million pressure cycles and operates reliably in the rigorous environments commonly found in HVAC/R and air compressor applications-18. The wide operating temperature range and ingress protection up to IP69K enable deployment in washdown environments and outdoor installations where moisture, dust, and temperature extremes are present-1.

Installation & Wiring Considerations

When installing the PX2 Series pressure transmitter, observe the following guidelines:

Torque Specifications: NPT ports are installed based on Turns From Finger Tight (TFFT) rather than specific torque values. When using NPT ports in stainless steel manifolds, use a thread sealant with anti-seize properties to prevent thread galling-25.

Installation Tools: Use appropriate tools such as an open-ended wrench or deep well socket. Always hand-start transducers into the mounting hole to prevent cross-threading and damage-25.

Overpressure Protection: Do not exceed the specified overpressure rating. Both static and dynamic overpressure must be considered, particularly in hydraulic system applications where pressure fluctuations can produce high peak pressures (water hammer effect). An oscilloscope is recommended for determining if high-pressure transients exist in a system. A pressure snubber may be used to reduce peak pressure applied to the transducer-25.

Electromagnetic Interference (EMI): Although the PX2 Series has been rated for high immunity to electrical noise (100 V/m radiated immunity), care should be taken when used near high-voltage sources that emit high levels of radiated electromagnetic energy, such as variable frequency motor drives, solenoids, radio transmitters, and engine ignition systems. The use of shielded cable and grounding of the pressure port is recommended-25.

Power Supply: Ensure the power supply is off while wiring. Ratiometric voltage devices require either a regulated 3.3 Vdc or regulated 5.0 Vdc supply depending on the specific model. All other versions can use an unregulated supply within the specified excitation ranges-25.

Ordering Information

When specifying the Honeywell PX2 Series Heavy Duty Pressure Transmitter, consider the following configuration parameters:

Pressure Range: Select from 1 bar to 70 bar (or equivalent in kPa/psi)

Pressure Reference: Absolute, Sealed Gage, or Vented Gage

Output Signal: 4–20 mA, 0.5–4.5 V ratiometric, 1–5 V, or 0–10 V

Pressure Port Type: Select from NPT, UNF, G-thread, or M-thread options

Electrical Connection: Packard Metri-Pack 150, Deutsch DT04-3P, cable harness, or custom

Accuracy Grade: Standard (±0.25% FSS) or economy (±0.5% FSS) where available

Consult the official Honeywell PX2 Series datasheet (document number 500599462) for the complete ordering matrix and available configuration codes-12.

 

 
 

 

 

 

 

 

Obtain relevant certificates and quotations for the product

Scroll to Top

Send Us a Message