Honeywell SMG890 Multivariable Transmitter
MODEL: SMG890 -S1-0-E1AC4A-1-0-AHH-11S-A-00A0-00-00000
Manufacturer: honeywell
Size: 35*30*26CM
Detail Specification: Multivariable Transmitter
Comment:Carton
Shipping Weight:6 Kg
Estimated Lead Time: 3 – 4 Weeks
Payment:T/T
HS CODE:9026201090
product details
Measurement Types:
Honeywell SMG890 Multivariable Transmitter is capable of mass flow measurements for liquids, gases, and superheated and saturated steam.
Personal Computer Configuration
Honeywell’s PC Based configuration Toolkit SCT3000 provides an easy way to configure the Honeywell SMG890 Multivariable Transmitter DE devices. SMV800 HART Device can be configured using Device Description based DCS Hosts and Asset Management Systems. HART device can also be configured using PC based DTMs. DTMs provide enhanced features like:
o
Easy to use Flow Configuration
o
Units Preference: Configurable Engineering units
o
Auto Calculation of Viscosity and Density
Coefficients, Auto Calculation of K User, Beta Factor
o
Export and Import Configurations to/from external file
with predefine schema/format
o
Summary Page
Primary Element Compatibility
FLOW: The SMV is compatible with and provides dynamic calculation capabilities. SMV800 supports Advanced Algorithms and ASME 1989 Algorithms which is User selectable option in the DD / DTM Tools. Advanced Algorithm option supports the following Primary Elements with SMV800 HART Protocol:
:
o Orifice Plates (ASME MFC-3M & AGA No 3/ISO
5167/GOST 8.586).
o Integral Orifice
o Small Bore Orifice (ASME MFC -14M)
o Conditional Orifice (ISO5167-2003)
o Nozzles (ASME MFC-3M/ISO 5167/GOST 8.586).
o Venturi Tubes (ASME MFC-3M/ISO 5167/GOST).
o Averaging Pitot Tubes
o V-Cone®, Wafer Cone, Wedge
ASME 1989 Algorithm Option supports the following
Primary Elements with SMV800 HART and DE protocol:
o
Orifice (Flange Taps D >/= 2.3 inches, Flange Taps
2 </= D </= 2.3, Corner Taps,Orifice D and D/2
Taps, Orifice 2.5 and 8D Taps)
o
Venturi (Machined Inlet, Rough Cast Inlet, Rough Welded Sheet-Iron Inlet, Leopold, Gerand, Venturi
Tube, Low-Loss Venturi Tube)
o
Nozzle (Long Radius, Venturi Nozzle)
o
Various Preso Ellipse Pitot Tubes with varying Pipe
Sizes
o
Other Pitot TubesSMV 800 Smart Pressure Transmitter
3
Primary Element Compatibility, continued
Fixed Parameters: Fixed Cd, Y1, Viscosity, Density are supported for user to customize the flow calculation
Temperature: The SMV also has the following temperature
input options:
o RTD (2,3,4 wires): PT25, PT100*, PT200, PT500, PT1000 (*DE models use only PT100 RTD)
o Universal Input: RTD PT25, PT100, PT200, PT500,
PT1000 and Thermocouple:
Type B*, E, J, K, N*, R*, S*, T.
*B, N , R, S Type inputs are only available with HART protocol
Mass Flow Calculation
Mass Flow Compensation can be selected for Standard Compensations by user for Gas, Liquid and Steam without limitation on primary elements. Mass Flow Compensation can be selected for Dynamic
Compensation by the user from: ASME-MFC-3M, ISO5167, Gost-8.586, for Orifice Plate, Nozzle and Venturri, AGA3 for Orifice, and Calculation Support for Averaging Pitot Tube, VCone,Wafer Cone,
Wedge and Integral Orifice and Conditional Orifice are also available. Mass Flow Calculations also support user Fixed Input Parameters for Customizing the Calculations.
System Integration
o
SmartLine communications protocols all meet the most
current published standards for HART/DE
o
Integration with Honeywell’s Experion PKS offers the following unique advantages.
o Messaging & Maintenance Mode Indication
o Tamper reporting
o FDM Plant Area Views with Health summaries
o All SMV 800 units are Experion tested to provide the highest level of compatibility assurance
Automatic Density Compensation
Using the configuration software, the SMV can be configured with the primary element type and the physical parameters of the fluid measured. This method dynamically compensates for fluid haracteristics such as discharge coefficients, gas expansion factors, density, and viscosity as well as
installation issues like upstream pipe size using the above referenced algorithms.
Basic Flow Density Compensation
This conventional calculation method is based on flow factors being manually entered
Modular Design
To help contain maintenance & inventory costs, all SMV 800 transmitters are modular in design supporting the user’s ability to replace meter bodies, indicators or change electronic
modules without affecting overall performance or approval body certifications. Each meter body is uniquely characterized to provide in-tolerance performance over a wide range of application variations in temperature and pressure and due to the Honeywell advanced interface, electronic
modules may be swapped without losing in-tolerance performance characteristics.
Modular Features
o
Meter body replacement
o
Replaceable electronics/comm modules*
o
Add or remove integral indicators*
o
Add or remove lightning protection (terminal connection)* * Field replaceable in all electrical environments (including IS) except flameproof without violating agency approvals. With no performance effects, Honeywell’s unique modularity results in lower inventory needs and lower overall operating
costs.
Description: SMG890 -S1-0-E1AC4A-1-0-AHH-11S-A-00A0-00-00000
SMG890 | Multivariable Pressure Transmitter,max measurement span:span:0-1000mbar |
S1 | Single Input – RTD (2/3/4 Wire) |
0 | Digital Output:No |
E | Diaphragm Material:316 SSL |
1 | Silicone Oil 200 |
A | Process connections:1/4 NPT female |
C | Bolt/Nut Materials:Carbon Steel |
4 | Vent/Drain Type/Location |
A | Gasket Material;Teflon® or PTFE (Glass Filled) |
1 | HighSide Left, Low Side Right2 / Std Head Orientation |
0 | No Approvals Required |
A | TRANSMITTER ELECTRONICS SELECTIONS:Polyester Powder Coated Aluminum Electrical connection:1/2 NPT female |
H | OUTPUT:HART Protocol |
H | Customer Interface SelectionsAdvanced |
1 | Standard Diagnostics |
1 | Output Limit:High Output Limits |
S | CONFIGURATION SELECTIONS:Factory Standard |
A | CALIBRATION & ACCURACY SELECTIONS:Standard |
0 | Mounting Bracket:Angle Bracket-316SST |
0 | Customer Tag:One Wired Stainless Steel Tag (Up to 4 lines 26 char/line) |
A0 | No Conduit Plugs or Adapters Required |
00 | Certifications Warranty:None – No additional options |
0000 | Factory Identification |
Hot Models:
SMG890 -S1-0-E1AC4A-1-0-AHH-11S-A-00A0-00-00000 |
SMG890 -S2-0-E2AC4A-1-0-AHC-11S-A-00A0-00-00000 |
SMG890 -S1-0-A1AC4A-1-0-AHH-11S-A-00A0-00-00000 |