pressure transmitter,temperature Transmitter,flow meter-ST-YK CLD

Honeywell STT17C temperature transmitter

Model: STT17C

Manufacturer: Honeywell

Size: 10*10*10cm

Detail Specification:temperature transmitter

Comment:Carton

Shipping Weight:3Kg

Estimated Lead Time: 4 Weeks

Payment:T/T

HS CODE:9026809000

product details

 Honeywell STT17C temperature transmitter

Product Overview

The Honeywell STT17C Configuration Toolkit is a PC-based configuration solution for the STT170 series of programmable temperature transmitters.-1 Designed for maintenance engineers and instrument technicians, the STT17C provides easy and quick access to all configuration parameters of STT171, STT173, and STT17H smart temperature transmitters.-8

The STT170 series — configurable via the STT17C — is Honeywell’s economy-tier family of temperature transmitters, flanking the existing mid-tier STT700 and high-tier STT750 & STT850 temperature transmitters.-8 These transmitters convert low-level signals from RTD and thermocouple temperature sensors into 4-20 mA current signals capable of transmitting long distances through noisy plant environments.-8 Compared to direct-wired temperature measurement points, STT170 series transmitters offer improved accuracy, safety, and reliability while significantly reducing wiring costs.-21

Key Technical Specifications — STT17C Configuration Toolkit

Parameter Specification
Manufacturer Honeywell Process Solutions
Model STT17C
Product Type PC-based configuration toolkit
Compatible Transmitters STT171, STT173, STT17H
Interface USB 1.1/2.0
Operating System Support Windows 98SE, ME, 2000, XP, Vista
Power Source USB bus-powered (no external supply required)
Galvanic Isolation Communication connector galvanically isolated from USB connection
Configuration Environment Non-hazardous locations only
Connection Method EZ-Mini-Hooks
Graphical User Interface Intuitive PC-based GUI — minimal operator training required
EC Declarations EMC Directive 2004/108/EC, Low Voltage Directive 2006/95/EC
Compliance Standards EN 61326-1:2006, EN 61010-1:2001
Operator Manual Document No. 34-ST-25-29

The STT17C configuration toolkit contains all necessary software and transmitter interface hardware to configure STT171, STT173, and STT17H transmitters.-18 The STT17C features a graphical user interface that virtually eliminates operator training requirements after PC installation.-18 The STT17C is powered directly by the PC’s USB port, eliminating the need for external power supplies.-12 For laptop users, power can be conserved by connecting the STT17C‘s USB connector to an externally powered USB hub.-16 The STT17C’s communication connector is galvanically isolated from the PC USB connection, protecting the PC from potential electrical interference.-12

Compatible Transmitters — Fully Configurable by STT17C

The STT17C is specifically designed to configure the following STT170 series temperature transmitters:

STT171 — Analog RTD-Only Temperature Transmitter (Configurable by STT17C)

Parameter Specification
Output 4-20 mA analog
Input Type RTD-only (Pt100, Ni100, Pt1000) or resistance input
Mounting DIN Form B head mount or DIN rail
Update Time 135 ms
Supply Voltage 8 to 30 VDC
Accuracy (Pt100) ±0.1°C
Sensor Error Response NAMUR NE43 compliant (upscale 23 mA, downscale 3.5 mA)
Programmable Damping 0.33 to 60 seconds
Dimensions 44 mm diameter × 20.2 mm height
Load Resistance 0 to 870 Ω — ≤ (V supply – 8)/0.023 A
Configuration STT17C configuration tool + PC

STT173 — Analog Universal Input Temperature Transmitter (Configurable by STT17C)

Parameter Specification
Output 4-20 mA analog
Input Type Universal (RTD, thermocouple, resistance, mV)
RTD Types Pt100, Ni100, Pt1000
Thermocouple Types E, J, K, L, N, R, S, T, B, U, W3, W5
Mounting DIN Form B head mount or DIN rail
Update Time 440 ms
Supply Voltage 8 to 35 VDC
Accuracy (Pt100, Ni100) ±0.1°C
Programmable Response Time 1 to 60 seconds
Sensor Error Response NAMUR NE43 compliant
Galvanic Isolation Yes (PC isolation)
Configuration STT17C configuration tool + PC

STT17H — HART/4-20 mA Universal Input Temperature Transmitter (Configurable by STT17C)

Parameter Specification
Output 4-20 mA with HART® protocol
Input Type Universal (RTD, thermocouple, resistance, mV)
Sensor Configuration Single sensor or dual sensor (difference or averaging)
RTD Types Pt100, Ni100, Pt1000
Thermocouple Types E, J, K, L, N, R, S, T, B, U, W3, W5
HART Multidrop Supported
Mounting DIN Form B head mount or DIN rail
Update Time 440 ms
Supply Voltage 8 to 35 VDC
Accuracy (Pt100, Ni100) ±0.1°C
Programmable Response Time 1 to 60 seconds
Sensor Error Response NAMUR NE43 compliant
Galvanic Isolation Yes (PC isolation)
Configuration STT17C configuration tool + PC, or HART field communicator

Common Specifications — All STT170 Series Transmitters (Configurable by STT17C):

Parameter Value
Output Current Range 4 to 20 mA
Power Supply Effect ≤0.005% of span per VDC
Operating Temperature -40°C to +85°C (-40°F to +185°F)
Relative Humidity 0 to 95% RH (Non-Condensing)
Vibration Tolerance Max 4g over 25 to 100 Hz
Sensor Error Detection NAMUR NE43 compliant
Alarm Levels Programmable high/low limits
Signal Linearization Automatic within user-defined upper/lower limits
Applications Cost-effective, programmable temperature monitoring

Configuration Capabilities of STT17C

The STT17C provides comprehensive configuration and monitoring capabilities for STT171, STT173, and STT17H transmitters:

Sensor Configuration: Select RTD, thermocouple, resistance, or mV input types; configure 2, 3, or 4-wire RTD connections

Range Setting: Define upper and lower measurement limits; automatic linearization of temperature signal output

Alarm Programming: Set high and low limit alarm points; configurable sensor failure response upscale (23 mA) or downscale (3.5 mA) per NAMUR NE43

Damping Adjustment: Programmable response time from 0.33 to 60 seconds (STT171) or 1 to 60 seconds (STT173, STT17H)

Sensor Matching: Configure transmitter to match calibrated RTD characteristics for enhanced accuracy

Real-Time Monitoring: Process variable display and diagnostics access during operation

Dual Sensor Management (STT17H only): Configure difference, average, or redundant measurement modes between two sensors

HART Multidrop Configuration (STT17H only): Address multiple transmitters on a single communication loop

Output Simulation: Loop testing and verification capabilities

Applications

The STT170 series — fully configurable by STT17C — is designed for cost-effective temperature monitoring applications:

Oil & Gas: Pipeline temperature monitoring, wellhead control

Chemical Processing: Reactor temperature measurement, batch process control

Power Generation: Bearing temperature monitoring, auxiliary system control

Pharmaceuticals: Cleanroom temperature monitoring, storage condition validation

Food & Beverage: Process temperature monitoring, cold chain management

HVAC: Building automation, environmental control systems

General Industrial: Equipment temperature monitoring, OEM machinery integration

The STT170 series transmitters are suitable for end users and Original Equipment Manufacturers (OEMs) requiring reliable and accurate temperature measurement in a cost-effective manner.-8 When ordering STT170 series transmitters, users can combine them with Honeywell temperature sensors and thermowells to form complete, installation-ready temperature measurement assemblies.-21

Safety Approvals & Certifications

The STT17C configuration toolkit carries EC Declaration of Conformity under EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC, with EN 61326-1:2006 and EN 61010-1:2001 compliance.-12

STT170 series transmitters configurable by STT17C are available with the following approvals:

Approval Scope
ATEX European hazardous area compliance (EN 50014, EN 50020, EN 50281)
FM Factory Mutual approvals (Intrinsic Safety, Non-Incendive, Dust Tight)
CSA Canadian Standards Association
CE Mark European conformity
IECEx International explosion protection
KEMA Hazardous area certifications
UL Underwriters Laboratories
RoHS Restriction of Hazardous Substances compliance
NAMUR NE43 Sensor error response compliance

Hazardous Area Classifications (FM/CSA/ATEX certified configurations):

Intrinsic Safety: Class I, Div. 2, Groups A, B, C, D, T4

Non-Incendive: Suitable for Class I, Division 2 hazardous locations

Dust Tight: Certified for combustible dust environments

Ordering Information

Attribute Detail
Product Number STT17C
Part Number STT3000 TEMPERATURE XMTR CONFIG. TOOL
Unit of Measure Each (includes software and all interface hardware)
Compatible Models STT171, STT173, STT17H — all configurable via STT17C
Documentation Reference Operator Manual 34-ST-25-29
Typical Lead Time Stock item — contact for current availability
Warranty Standard Honeywell industrial components warranty applies

The STT17C configuration toolkit is delivered factory-ready, complete with software installation media and all necessary EZ-Mini-Hook connection hardware for immediate field use with STT171, STT173, and STT17H transmitters.

 

 

 

Obtain relevant certificates and quotations for the product

Scroll to Top

Send Us a Message