Micro Motion F050 Flow and Density Meter
Model:F050S176C0AVHZZZZ
Manufacturer: Micro Motion
Size: 50*50*45cm
Detail Specification: Flow and Density Meter
Comment:Carton
Shipping Weight:50Kg
Estimated Lead Time: 8 Weeks
Payment:T/T
HS CODE:9026201090
product details
Product Overview
The Micro Motion F050 Series is a compact, drainable Coriolis flow and density meter engineered for 0.5-inch (DN15) process lines, delivering direct inline measurement of mass flow, volume flow, density, temperature, and concentration from a single device. Designed to fit tight installation spaces without sacrificing measurement integrity, the F050 platform combines Micro Motion’s MVD transmitter technology with a dual-tube sensor architecture that eliminates moving parts and minimizes maintenance costs over the instrument’s service life.
The F050 is available in five model variants to match specific process conditions:
| Model | Wetted Material | Application Designation |
| F050S | 316L Stainless Steel | Standard |
| F050A | 316L Stainless Steel | High Temperature |
| F050H | Nickel Alloy C22 | Standard |
| F050B | Nickel Alloy C22 | High Temperature |
| F050P | 316L Stainless Steel | High Pressure |
The letter suffix denotes the material of wetted parts or the application designation: S = stainless steel, H = nickel alloy C22, P = high pressure, A = 316L stainless steel for high temperature, B = nickel alloy C22 for high temperature.
Technical Specifications
Flow Measurement
| Parameter | Specification |
| Liquid mass flow accuracy | ±0.20% of rate (standard); ±0.15% of rate (optional); ±0.10% of rate (optional) |
| Liquid mass flow repeatability | ±0.050% of rate |
| Liquid volume flow accuracy | ±0.20% of rate (standard); ±0.15% of rate (optional); ±0.10% of rate (optional) |
| Liquid volume flow repeatability | ±0.050% of rate |
| Gas mass flow accuracy | ±0.5% of rate |
| Gas mass flow repeatability | ±0.25% of rate |
Density and Temperature
| Parameter | Specification |
| Liquid density accuracy | ±0.002 g/cm³ (2.0 kg/m³) standard; ±0.001 g/cm³ (1.0 kg/m³) optional |
| Temperature accuracy | ±1 °C ±0.5% of reading |
| Density range | Up to 3 g/cm³ (3000 kg/m³) |
Pressure Ratings by Model
| Model | Maximum Working Pressure |
| F050S / F050H | 1,450 psig (100 barg) |
| F050A / F050B | 1,450 psig (100 barg) |
| F050P | 5,000 psig (344 barg) |
The F050P variant is specifically engineered for high-pressure service, with a maximum sensor working pressure of 5,000 psig (344 barg), making it suitable for demanding applications in oil and gas, chemical injection, and high-pressure process control.
Sensor Geometry
| Model | Number of Tubes | Tube ID (inches) | Tube ID (mm) | Tube Length (inches) | Tube Length (mm) |
| F050S/H/A/B | 2 | 0.35 | 8.8 | 18.8 | 478 |
| F050P | 2 | 0.26 | 6.6 | 18.8 | 478 |
The F050P utilizes a narrower tube internal diameter (6.6 mm vs. 8.8 mm) to withstand the higher pressure requirements while maintaining the same overall tube length as other F050 variants.
Key Features and Benefits
Compact, Drainable Design — The F050’s self-draining flow path enables complete evacuation of process fluid, making it ideal for batch operations, food and beverage processing, and applications where cross-contamination between batches is unacceptable.
Single-Device Multivariable Measurement — One instrument simultaneously outputs mass flow, volume flow, density, temperature, and concentration, reducing installation complexity and eliminating the need for multiple sensors.
Material Options for Corrosive Service — The F050H and F050B models feature Nickel Alloy C22 wetted parts for superior resistance to chlorides, oxidizing media, and aggressive chemical environments. The F050S and F050A models use 316L stainless steel for general-purpose and high-temperature applications respectively.
No Moving Parts — The Coriolis measurement principle relies on vibrating tubes rather than mechanical components, eliminating wear-related maintenance and ensuring long-term measurement stability.
Smart Meter Verification — Real-time, in-process verification of measurement integrity without interrupting production, providing continuous assurance of calibration health.
Broad Certification Coverage — Available with UL, CSA, IECEx, NEPSI, and ATEX approvals, plus ingress protection ratings of IP66/67 and NAMUR compliance for use in demanding industrial environments.
Transmitter Compatibility
The F050 sensor integrates with the full range of Micro Motion transmitters, including the 1500, 1600, 1700, 2500, 2700, 3500, 3700, 4200, 4700, and 5700 series. Available in both integral and remote mount configurations, the transmitter platform supports HART, WirelessHART, and multiple I/O configurations to suit distributed control systems, PLC-based architectures, and standalone monitoring setups.
Typical Applications
Chemical injection and dosing — Precise mass-based measurement for additive and catalyst feed systems
Oil and gas custody transfer — MID OIML R 117 and NTEP approved configurations for fiscal measurement
Food and beverage processing — Hygienic, drainable design for batch recipe control and concentration measurement
Pharmaceutical manufacturing — Accurate density and concentration measurement for formulation processes
High-pressure process control — F050P variant for pressures up to 5,000 psig in hydrogen, natural gas, and supercritical fluid applications
Frequently Asked Questions
Q: What is the difference between F050S and F050A?
The F050S is the standard 316L stainless steel model for general-purpose liquid and gas measurement. The F050A uses the same 316L stainless steel wetted parts but is designated for high-temperature service, extending the usable process temperature range for applications such as hot oil, steam condensate, and high-temperature chemical processes.
Q: When should I choose the F050H or F050B over the stainless steel models?
Choose the F050H (standard) or F050B (high temperature) when your process fluid is corrosive to 316L stainless steel — particularly in the presence of chlorides, oxidizing acids, or aggressive chemical media. Nickel Alloy C22 provides significantly better corrosion resistance in these environments while maintaining identical flow measurement performance.
Q: What makes the F050P suitable for high-pressure applications?
The F050P features a modified flow tube design with a smaller internal diameter (6.6 mm vs. 8.8 mm) that reduces hoop stress under pressure, enabling a maximum working pressure rating of 5,000 psig (344 barg) — more than three times the rating of the standard F050S/H models.
Ordering Information
The complete model code for this configuration is F050S176C0AVHZZZZ, where:
F050 — Sensor size 0.5 in (DN15)
S — 316L stainless steel wetted parts
176 — Process connection and flange configuration code
C — Calibration option
0 — Approval and certification code
AVHZZZZ — Transmitter and output configuration
For custom configurations, contact your local Micro Motion representative or use the online sizing and selection tool to match the F050 to your specific process requirements.