Micro Motion F200 Flow and Density Meter
Model:F200SA32C2BZPZZZZMCRTHT
Manufacturer: Micro Motion
Size: 100*80*50CM
Detail Specification: Flow and Density Meter
Comment:wooden case
Payment:T/T
HS CODE:9026201090
Delivery time: 8-10 weeks
product details
Micro Motion F200 Flow and Density Meter
Product Overview
The Micro Motion F200SA32C2BZPZZZZMCRTHT is a 2-inch (DN50) Coriolis flow and density meter built on the F200S sensor platform — the fourth size in Emerson’s compact, drainable F-Series line. The trailing “S” confirms a 316L stainless steel wetted path, delivering direct mass flow, volume flow, density, and temperature measurement from a single instrument.
The F200S sits between the 1½-inch F150 and the 3-inch F300, making it the workhorse choice for moderate-to-high flow rate applications where a 2-inch line is standard. Its dual-tube, drainable architecture ensures complete product recovery during batch changeovers and CIP cycles. The meter’s ±0.20% mass flow accuracy and ±0.002 g/cm³ density accuracy are standard for this class, with optional upgrades pushing both specifications into custody-transfer territory. This configuration ships with a Micro Motion 1600 compact transmitter (the “MCRTHT” suffix), creating a self-contained measurement package ready for field installation.
Technical Specifications — F200SA32C2BZPZZZZMCRTHT
| Parameter | Specification |
| Base Sensor | F200S |
| Line Size | 2 in (DN50) |
| Wetted Material | 316L Stainless Steel |
| Flow Tube Configuration | Dual tube, drainable |
| Mass Flow Accuracy (Liquid) | ±0.20% of rate (standard); ±0.15% / ±0.10% optional |
| Mass Flow Repeatability (Liquid) | ±0.050% of rate |
| Volume Flow Accuracy (Liquid) | ±0.20% of rate (standard); ±0.15% / ±0.10% optional |
| Volume Flow Repeatability (Liquid) | ±0.050% of rate |
| Mass Flow Accuracy (Gas) | ±0.5% of rate |
| Mass Flow Repeatability (Gas) | ±0.25% of rate |
| Density Accuracy (Liquid) | ±0.002 g/cm³ (2.0 kg/m³) standard; ±0.001 g/cm³ optional; ±0.0005 g/cm³ optional |
| Temperature Accuracy | ±1 °C ±0.5% of reading |
| Sensor Maximum Working Pressure | 1,450 psig (100 barg) |
| Transmitter | Micro Motion 1600 Compact |
| Approvals | UL, CSA, IECEx, NEPSI, ATEX, Ingress Protection (IP66/67), EMC effects |
The ±0.20% liquid mass flow accuracy is the F200S baseline, but the meter is factory-configurable to ±0.10% for applications demanding tighter control. Gas flow accuracy at ±0.5% of rate with ±0.25% repeatability makes the F200S equally viable for natural gas and compressed gas measurement. The enhanced density calibration option at ±0.0005 g/cm³ (0.5 kg/m³) is available on the F200S, but not on high-temperature or high-pressure F-Series variants.
The F200S carries custody transfer approvals from MID OIML R 117, NTEP, Measurement Canada, and INMETRO Brazil — a credential set that opens doors to fiscal measurement and trade applications. Marine approvals include ABS, BV, CCS, DNV, LR, KR, NKK, and RINA.
Model String Decoded: F200SA32C2BZPZZZZMCRTHT
Every segment of the model number corresponds to a configuration decision:
F200 — F-Series compact, drainable platform; 2 in (DN50) line size
S — 316L stainless steel wetted parts. Per Emerson’s F-Series nomenclature, the trailing letter after the size code designates material or application: S for stainless steel, H for nickel alloy C22, A for high-temperature 316L, B for high-temperature nickel alloy, and P for high-pressure service
A32 — Process connection configuration code for the DN50 flange and fitting arrangement
C2 — Process connection type and pressure rating code
B — Additional sensor configuration (orientation, drainability, or connection variant)
Z — Calibration and accuracy option code; standard calibration unless upgraded
P — Pressure-containing configuration designation
ZZZZ — Reserved placeholders for options not selected in this build
MCRTHT — Transmitter and electronics package: M (Micro Motion), C (compact), R (mounting code), T (transmitter family), HT (high-temperature rating or HART communication variant)
F-Series Material Options: S, A, H, B, and P Compared
The F200 platform is available in five wetted-material and application configurations:
F200S — 316L stainless steel, standard temperature and pressure. Maximum working pressure: 1,450 psig (100 barg). The most widely deployed variant for hydrocarbon liquids, water, chemicals, and general process fluids.
F200A — 316L stainless steel, high-temperature version. Extends the fluid temperature envelope for hot process streams.
F200H — Nickel alloy C22, standard temperature. Maximum working pressure: 2,160 psig (149 barg). C22 resists chlorides, oxidizing acids, and aggressive chemical media that would degrade 316L.
F200B — Nickel alloy C22, high-temperature version.
F200P — Nickel alloy C22, high-pressure version. Rated to 6,250 psig (430 barg) — more than four times the F200S limit — with a rupture disk for overpressure protection.
For the F200SA32C2BZPZZZZMCRTHT configuration, the “S” confirms 316L construction at the 100 barg pressure ceiling. If the application involves aggressive chlorides, high-temperature caustics, or pressures exceeding 100 barg, an F200H or F200P alternative should be evaluated before specification.
Transmitter: Micro Motion 1600 Compact
The included 1600 transmitter is a field-mountable unit designed for space-constrained installations. Key capabilities include:
Display: Backlit graphical display with four-button mechanical controls; language support for English, German, French, Spanish, Portuguese, Russian, Chinese, and Japanese
Power: 18–100 VDC (6 watts typical, 11 watts maximum) or 85–240 VAC (3.5 watts typical, 8 watts maximum); Power over Ethernet available on Ethernet versions, compliant with IEEE 802.3at and 802.3af
Service Port: Universal USB-C port for configuration and data transfer using a standard terminal
Communication: HART (Bell 202 superimposed on primary analog output), Modbus RS-485, and EtherNet/IP + Modbus TCP on Ethernet versions
Outputs: One active 4–20 mA analog output, one active pulse output, plus an additional configurable channel for mA, pulse, or discrete output