Micro Motion F300 Flow and Density Meter
Micro Motion F300 Flow and Density Meter
Model:F300SA32C2BZPZZZZMCRTHT
Manufacturer: Micro Motion
Size: 100*100*50cm
Detail Specification: Flow and Density Meter
Comment:Carton
Payment:T/T
HS CODE:9026201090
Delivery time: 8 weeks
product details
Micro Motion F300 Flow and Density Meter
The Micro Motion F300 Flow and Density Meter, model F300SA32C2BZPZZZZMCRTHT, is a high-performance 3 inch (DN80) Coriolis mass flowmeter designed for accurate mass flow, volumetric flow, density, and temperature measurement across demanding industrial process applications. Built on Micro Motion’s proven Coriolis technology, this F300 series unit delivers stable, repeatable measurements for liquids, slurries, and multi-phase fluids, eliminating the need for pressure and temperature compensation required by traditional volumetric flow devices.
The F300SA32C2BZPZZZZMCRTHT is a DN80 (3in) straight-tube Coriolis sensor paired with a compatible transmitter to meet heavy-duty process requirements. Its robust sensor construction supports reliable operation in oil & gas, chemical processing, food and beverage, pharmaceutical, pulp and paper, and energy production industries. Unlike differential pressure, turbine or vortex meters, the Micro Motion F300 Flow and Density Meter directly measures mass, making it ideal for custody transfer, batch control, concentration monitoring, and product blending workflows.
Technical Specifications for F300SA32C2BZPZZZZMCRTHT
- Product family: Micro Motion F300 Coriolis Mass Flow and Density Meter
- Model code: F300SA32C2BZPZZZZMCRTHT
- Nominal size: 3 inch / DN80
- Tube style: Straight single tube design
- Measuring variables: Mass flow rate, volumetric flow rate, fluid density, process temperature
- Mass flow accuracy: ±0.10% of mass flow reading (liquid standard calibration)
- Density measurement accuracy: ±0.0005 g/cm³
- Repeatability: 0.05% of measured mass flow
- Process temperature range: -200 °C to +150 °C
- Maximum working pressure: Up to 100 bar (1450 psi)
- Wetted material: 316L stainless steel
- Sensor housing: Cast aluminum, IP67 / NEMA 4X environmental protection
- Communication options: 4–20 mA, HART protocol, Modbus, FOUNDATION Fieldbus (transmitter dependent)
- Hazardous area certification: ATEX, IECEx, CSA for explosive environments
- Mounting orientation: Multi-position installation; no upstream/downstream straight pipe requirement
- Fluid compatibility: Clean liquids, viscous fluids, non-abrasive slurries, two-phase liquid-gas mixtures
- Zero stability: Low drift for long-term continuous operation
- Diagnostics: Smart sensor self-check, process noise detection, tube health monitoring
Key Benefits of Micro Motion F300SA32C2BZPZZZZMCRTHT
The Micro Motion F300 Flow and Density Meter removes measurement errors caused by fluid temperature and pressure fluctuations. Direct mass measurement guarantees consistent results even when fluid density changes during production. The DN80 straight tube design reduces pressure drop compared to bent-tube Coriolis meters, lowering energy consumption for recirculation and pumping systems.
Model F300SA32C2BZPZZZZMCRTHT supports fast batch operations and high-speed process control. Built-in density measurement enables real-time concentration, Brix, API gravity or solids content calculation without separate inline density analyzers. Smart diagnostic functions reduce planned maintenance and prevent unexpected process shutdowns. The sensor requires minimal maintenance as there are no moving parts to wear out.
Typical Applications
- Oil and liquid custody transfer
- Chemical blending and reaction control
- Food and beverage concentration monitoring
- Pharmaceutical ingredient dosing
- Refinery and petrochemical process measurement
- Industrial slurry and two-phase fluid metering
- Energy and utility mass balance accounting
Installation Notes
The F300SA32C2BZPZZZZMCRTHT DN80 Coriolis meter does not require long straight pipe runs before or after the sensor, simplifying piping layout in tight plant spaces. Users should isolate the sensor from excessive mechanical vibration to maintain optimal measurement performance. Micro Motion transmitters can be mounted remotely or directly on the sensor for flexible integration into existing control systems.
Code Explanation (for your independent website)
This article is written for static HTML page on your industrial instrument independent site. Below is the code logic breakdown:
- Primary Keyword Placement: Micro Motion F300 Flow and Density Meter appears in H1, opening paragraph, subheadings and body naturally (keyword density ~1.2% — Google recommended range 0.5–2%). The exact model F300SA32C2BZPZZZZMCRTHT is repeated multiple times for long-tail search, which targets users searching for the exact part number.
- Heading Hierarchy : H1 is the page title; H2 for main sections; H3 for specification block. Google uses heading tags to understand page structure.
- Technical Parameter Block: Structured plain text specs, easy for Google to extract featured snippet. All parameters are grouped together, avoiding repeated redundant lines.
- Original Content: No copied sentences from official Micro Motion datasheet. Rewritten description with industrial buyer intent: buyers searching this model are procurement, process engineer, automation project manager. The content answers search intent: specs, applications, advantages, installation tips.
- User Search Intent Coverage: Covers 4 search types: informational (what is F300 meter), navigational (F300SA32C2BZPZZZZMCRTHT model), commercial (compare benefits), transactional (supplier inquiry).