Rosemount 5402 Level Transmitter: High-Frequency Non-Contacting Radar Level Transmitter
Rosemount 5402 is a high-frequency (~26 GHz) two-wire non-contacting radar level transmitter engineered for precise level measurement of liquids, slurries, and solids across demanding industrial environments. Featuring Dual Port Technology and circular polarization, the 5402 delivers reliable performance even under challenging conditions including turbulence, foam, condensation, and low-dielectric media.
Key Technical Specifications
| Parameter | Specification |
| Operating Frequency | ~26 GHz (K-band) |
| Measurement Range | Up to 35 m (115 ft) from flange |
| Accuracy | ±3 mm (±0.1 in.) under reference conditions |
| Repeatability | ±1 mm (±0.04 in.) |
| Resolution | 1 mm (0.04 in.) |
| Near Zone Distance | 0.4 m (1.3 ft) from antenna bottom |
| Transition Zone | 150 mm (6 in.) from antenna bottom |
| Minimum Dielectric Constant (εr) | 1.4 |
| Microwave Output Power | < 1 mW |
| Update Interval | 1 second |
| Maximum Level Change Rate | 40 mm/s default; adjustable to 180 mm/s |
| Process Temperature | -40 to 150°C (-40 to 302°F); up to 200°C (392°F) with parabolic antenna |
| Process Pressure | Full vacuum to 16 bar (232 psi) |
| Ambient Temperature | -40 to 80°C (-40 to 176°F) |
| Temperature Dependence | 0.05% per 10 K over -40°C to 80°C |
| Output Signal | 4-20 mA with HART®; Foundation™ Fieldbus; Modbus® |
| Power Supply | 16-42.4 VDC (loop powered) |
| Housing Material | Polyurethane-covered aluminum or stainless steel CF8M |
| Ingress Protection | Type 4X, IP66/IP67 |
| Display | 5-digit integral LCD (optional) |
Antenna Types and Applications
The Rosemount 5402 offers multiple antenna configurations to suit varied process conditions:
Cone Antenna: Build-up resistant design suitable for stilling wells, vertical pipes, and smooth nozzles. Available in 2-inch to 8-inch sizes with materials including 316L stainless steel and Hastelloy® C-276. Beam angles range from 19° (2-inch) to 9° (4-inch).
Process Seal Antenna: Ideal for small tanks, corrosive fluids, and applications with heavy condensation or stratification tendency. The enlarged PTFE tank seal protects the antenna from contamination.
Parabolic Antenna: Extends measurement range for solids applications in tall vessels. The narrow beam focuses energy output, improving accuracy for uneven surfaces up to 32 m (105 ft).
Rod Antenna: Designed for small process connections and corrosive environments.
Operating Principle
The Rosemount 5402 measures level by transmitting short radar pulses from the antenna toward the product surface. When the pulse reaches a medium with different dielectric properties, a portion of the energy reflects back to the transmitter. The time difference between transmitted and reflected pulses determines the distance to the product surface, from which level, volume, and level rate are calculated.
Advanced Signal Processing Technologies
Dual Port Technology: The 5402 features two separate ports for transmitting and receiving microwave signals, generating more than 75% stronger signal strength than single-port transmitters. This enables reliable measurement even when reflected energy is weak due to low-dielectric products, turbulence, or long measurement ranges.
Circular Polarization: Unlike conventional linear polarization, circular polarization minimizes interference from tank walls, obstructions, and disturbing objects. This allows installation without clearance distance from tank walls, increasing mounting flexibility.
Condensation-Resistant Antenna: The enlarged PTFE tank seal protects the antenna from process atmosphere contamination, ensuring consistent performance in high-humidity and condensing applications.
Configuration and Integration
The Rosemount 5402 is a loop-powered device supporting both 4-20 mA with HART® and Foundation™ Fieldbus protocols. Configuration is accomplished via Rosemount RadarMaster software (included), providing a five-step wizard, automatic connection, and online help. The transmitter also supports DD-compatible tools including AMS Device Manager, DeltaV, and 375 Field Communicator.
The integral five-digit display can show level, distance, volume, level rate, signal strength, internal temperature, analog output current, and percentage of range.
Model Code Example: 5402AH1NA3SPVBAM1
| Code Segment | Description |
| 5402 | High-frequency version (~26 GHz) |
| A | Housing Material: Polyurethane-covered Aluminum |
| H | Signal Output: 4-20 mA with HART communication |
| 1 | Conduit/Cable Threads: ½ inch – 14 NPT |
| NA | Product Certifications: No product certificates |
| 3S | Antenna: 3-inch cone, 316L SST (EN 1.4404) |
| PV | Process Connection: ANSI 3-inch 150 lb flange, 316 SST |
| BA | Flange: 3-inch, 150 lb ANSI |
| M1 | Integral Digital Display |
| C1 | Factory Configuration |
Common Rosemount 5402 Model Numbers
| Model Number | Key Features |
| 5402AH1NA2SPVAAM1T1C1N2SBS | 2-inch cone, FM intrinsic safety, transient protection, marine cert |
| 5402AH1NA3PNABAM1Q4 | 3-inch process seal, no product cert, calibration cert |
| 5402AH1NA3SPVCA | 3-inch cone, 4-inch flange, integral display |
| 5402AH1NA4SNACA | 4-inch cone, 3-inch flange, no display |
| 5402AH1E54SPVCA | 4-inch cone, ATEX flameproof, 4-inch flange |
| 5402AH1E64SPVDAM1C1S3 | 4-inch cone, CSA explosion-proof, antenna extension |
| 5402AFMNA4SPECAM1C1Q4 | Foundation Fieldbus, 4-inch process seal, calibration cert |
| 5402AH1I14SPVCB | 4-inch cone, ATEX intrinsic safety, 4-inch 300 lb flange |
Certifications and Approvals
The Rosemount 5402 carries global certifications including ATEX, FM, CSA, IECEx, NEPSI, INMETRO, and EAC for explosion-proof and intrinsic safety applications. The transmitter is TÜV tested and WHG approved for overfill prevention, with optional NACE MR0175/ISO 15156 compliance for sour service.
Why Choose the Rosemount 5402?
Superior Signal Strength: Dual Port Technology delivers 75% more signal power than standard two-wire radar transmitters
Installation Flexibility: Circular polarization eliminates clearance requirements from tank walls
Reliable Performance: Advanced echo tracking maintains measurement integrity under turbulence, foam, and condensation
Low Maintenance: Non-contacting design with no moving parts eliminates wear and recalibration requirements
Broad Application Coverage: Measures liquids, slurries, and solids with dielectric constants as low as 1.4
Global Compliance: Extensive certification portfolio enables installation worldwide in hazardous areas