pressure transmitter,temperature Transmitter,flow meter-ST-YK CLD

Rosemount 5402 Level Transmitter

Rosemount 5402 Level Transmitter

MODEL: 5402AH2I12PNAHB

Manufacturer: Rosemount

Size:70*20*20cm

Detail Specification:level Transmitter

Comment:Carton

Shipping Weight: 18 Kg

Estimated Lead Time: 6 – 8 Weeks

Payment:T/T

product details

Rosemount 5402 Level Transmitter

Rosemount 5402 Level Transmitter: High-Frequency Non-Contacting Radar Level Transmitter

Rosemount 5402 is a high-frequency (~26 GHz) two-wire non-contacting radar level transmitter engineered for precise level measurement of liquids, slurries, and solids across demanding industrial environments. Featuring Dual Port Technology and circular polarization, the 5402 delivers reliable performance even under challenging conditions including turbulence, foam, condensation, and low-dielectric media.

Key Technical Specifications

ParameterSpecification
Operating Frequency~26 GHz (K-band)
Measurement RangeUp to 35 m (115 ft) from flange
Accuracy±3 mm (±0.1 in.) under reference conditions
Repeatability±1 mm (±0.04 in.)
Resolution1 mm (0.04 in.)
Near Zone Distance0.4 m (1.3 ft) from antenna bottom
Transition Zone150 mm (6 in.) from antenna bottom
Minimum Dielectric Constant (εr)1.4
Microwave Output Power< 1 mW
Update Interval1 second
Maximum Level Change Rate40 mm/s default; adjustable to 180 mm/s
Process Temperature-40 to 150°C (-40 to 302°F); up to 200°C (392°F) with parabolic antenna
Process PressureFull vacuum to 16 bar (232 psi)
Ambient Temperature-40 to 80°C (-40 to 176°F)
Temperature Dependence0.05% per 10 K over -40°C to 80°C
Output Signal4-20 mA with HART®; Foundation™ Fieldbus; Modbus®
Power Supply16-42.4 VDC (loop powered)
Housing MaterialPolyurethane-covered aluminum or stainless steel CF8M
Ingress ProtectionType 4X, IP66/IP67
Display5-digit integral LCD (optional)

Antenna Types and Applications

The Rosemount 5402 offers multiple antenna configurations to suit varied process conditions:

Cone Antenna: Build-up resistant design suitable for stilling wells, vertical pipes, and smooth nozzles. Available in 2-inch to 8-inch sizes with materials including 316L stainless steel and Hastelloy® C-276. Beam angles range from 19° (2-inch) to 9° (4-inch).

Process Seal Antenna: Ideal for small tanks, corrosive fluids, and applications with heavy condensation or stratification tendency. The enlarged PTFE tank seal protects the antenna from contamination.

Parabolic Antenna: Extends measurement range for solids applications in tall vessels. The narrow beam focuses energy output, improving accuracy for uneven surfaces up to 32 m (105 ft).

Rod Antenna: Designed for small process connections and corrosive environments.

Operating Principle

The Rosemount 5402 measures level by transmitting short radar pulses from the antenna toward the product surface. When the pulse reaches a medium with different dielectric properties, a portion of the energy reflects back to the transmitter. The time difference between transmitted and reflected pulses determines the distance to the product surface, from which level, volume, and level rate are calculated.

Advanced Signal Processing Technologies

Dual Port Technology: The 5402 features two separate ports for transmitting and receiving microwave signals, generating more than 75% stronger signal strength than single-port transmitters. This enables reliable measurement even when reflected energy is weak due to low-dielectric products, turbulence, or long measurement ranges.

Circular Polarization: Unlike conventional linear polarization, circular polarization minimizes interference from tank walls, obstructions, and disturbing objects. This allows installation without clearance distance from tank walls, increasing mounting flexibility.

Condensation-Resistant Antenna: The enlarged PTFE tank seal protects the antenna from process atmosphere contamination, ensuring consistent performance in high-humidity and condensing applications.

Configuration and Integration

The Rosemount 5402 is a loop-powered device supporting both 4-20 mA with HART® and Foundation™ Fieldbus protocols. Configuration is accomplished via Rosemount RadarMaster software (included), providing a five-step wizard, automatic connection, and online help. The transmitter also supports DD-compatible tools including AMS Device Manager, DeltaV, and 375 Field Communicator.

The integral five-digit display can show level, distance, volume, level rate, signal strength, internal temperature, analog output current, and percentage of range.

Model Code Example: 5402AH1NA3SPVBAM1

Code SegmentDescription
5402High-frequency version (~26 GHz)
AHousing Material: Polyurethane-covered Aluminum
HSignal Output: 4-20 mA with HART communication
1Conduit/Cable Threads: ½ inch – 14 NPT
NAProduct Certifications: No product certificates
3SAntenna: 3-inch cone, 316L SST (EN 1.4404)
PVProcess Connection: ANSI 3-inch 150 lb flange, 316 SST
BAFlange: 3-inch, 150 lb ANSI
M1Integral Digital Display
C1Factory Configuration

Common Rosemount 5402 Model Numbers

Model NumberKey Features
5402AH1NA2SPVAAM1T1C1N2SBS2-inch cone, FM intrinsic safety, transient protection, marine cert
5402AH1NA3PNABAM1Q43-inch process seal, no product cert, calibration cert
5402AH1NA3SPVCA3-inch cone, 4-inch flange, integral display
5402AH1NA4SNACA4-inch cone, 3-inch flange, no display
5402AH1E54SPVCA4-inch cone, ATEX flameproof, 4-inch flange
5402AH1E64SPVDAM1C1S34-inch cone, CSA explosion-proof, antenna extension
5402AFMNA4SPECAM1C1Q4Foundation Fieldbus, 4-inch process seal, calibration cert
5402AH1I14SPVCB4-inch cone, ATEX intrinsic safety, 4-inch 300 lb flange

Certifications and Approvals

The Rosemount 5402 carries global certifications including ATEX, FM, CSA, IECEx, NEPSI, INMETRO, and EAC for explosion-proof and intrinsic safety applications. The transmitter is TÜV tested and WHG approved for overfill prevention, with optional NACE MR0175/ISO 15156 compliance for sour service.

Why Choose the Rosemount 5402?

Superior Signal Strength: Dual Port Technology delivers 75% more signal power than standard two-wire radar transmitters

Installation Flexibility: Circular polarization eliminates clearance requirements from tank walls

Reliable Performance: Advanced echo tracking maintains measurement integrity under turbulence, foam, and condensation

Low Maintenance: Non-contacting design with no moving parts eliminates wear and recalibration requirements

Broad Application Coverage: Measures liquids, slurries, and solids with dielectric constants as low as 1.4

Global Compliance: Extensive certification portfolio enables installation worldwide in hazardous areas

Obtain relevant certificates and quotations for the product