SIEMENS 7MF4034 Gauge Pressure Transmitter
SIEMENS 7MF4034 Gauge Pressure Transmitter
Model:7MF4034-1DA10-2AB6
Manufacturer: Siemens
Size: 30*25*30cm
Detail Specification: Gauge Pressure Transmitter
Comment:Carton
Shipping Weight:4Kg
Payment:T/T
HS CODE:9026201090
Delivery time: 8 weeks
product details
SIEMENS 7MF4034 Gauge Pressure Transmitter
SIEMENS 7MF4034 Gauge Pressure Transmitter — PROFIBUS PA Digital Pressure Measurement for Process Automation
The SIEMENS 7MF4034 Gauge Pressure Transmitter is the PROFIBUS PA variant within the SITRANS P DS III / P410 pressure transmitter family, configured specifically for gauge pressure measurement in digitally integrated process control systems. Unlike 4–20 mA/HART counterparts, the 7MF4034 series transmits measurement values, status information, and diagnostic data over a single PROFIBUS PA segment, making it a practical choice for plants already operating on fieldbus infrastructure or for projects seeking to reduce point-to-point wiring in hazardous areas.
Position within the SITRANS P DS III / P410 Family
Siemens organizes the DS III / P410 generation by measurement task and communication protocol. The 7MF4033 prefix identifies gauge pressure transmitters with 4–20 mA / HART communication, while 7MF4034 denotes the gauge pressure configuration with PROFIBUS PA output. The same platform supports absolute pressure (7MF4233) and differential pressure / flow (7MF4433, 7MF4533) measurement, sharing the same measuring cell architecture and housing family.
Key Technical Specifications
The following values represent the 7MF4034 gauge pressure platform across its standard configurations. Final limits depend on the complete MLFB (order code), particularly the measuring cell filling, nominal range, process connection, and explosion protection suffix.
| Parameter | Specification |
| Measurement task | Gauge pressure (relative pressure) |
| Communication protocol | PROFIBUS PA (IEC 61158-2, MBP physical layer) |
| Accuracy | ≤ 0.075 % of span (including hysteresis and repeatability) |
| Long-term stability | ≤ 0.25 % per 60 months |
| Measuring span (effective range) | 1 mbar to 400 bar (approximately 0.015 psi to 5802 psi), depending on the measuring cell |
| Nominal measuring ranges (standard steps) | 250 mbar, 1 bar g, 4 bar g, 16 bar g, 63 bar g, 160 bar g, 400 bar g |
| Turndown | Up to 100:1 (span-dependent) |
| Overload limit | Typically 2× the nominal range for lower spans; consult the MLFB for specific values (e.g., 16 bar g nominal → 32 bar overload) |
| Measuring cell filling | Silicone oil (standard) or inert liquid (grease-free, order code 3) |
| Wetted diaphragm material | Stainless steel (1.4404 / 316L) or Hastelloy C276 (2.4819) |
| Process connection options | G½A female, ½–14 NPT female, oval flange stainless steel, M20 × 1.5 male, ½–14 NPT male, mounting threads 1/16–20 UNF, M10, M12 |
| Housing material | Die-cast aluminium or stainless steel precision casting |
| Degree of protection | IP66 / IP67 (depending on electrical connection) |
| Ambient temperature influence | Additional error included in the ≤ 0.075 % total accuracy figure; temperature effect data available per span ratio in Siemens documentation |
| Diagnostic functions | Event counter, limit transmitter, saturation alarm, slave pointer, simulation functions, maintenance timer, zero-point correction |
| Functional safety | SIL 2 capable in suitable MLFB configurations; MTBF approximately 797 years |
| Hazardous area approvals | CENELEC EEx ia, EEx d, EEx nA/nL, FM + CSA (is + xp), dust Zone 1D/2D (not for FF variant) |
What the PROFIBUS PA Configuration Brings to the Installation
Choosing the 7MF4034 over a 4–20 mA transmitter changes the integration layer rather than the pressure-sensing principle. The measuring cell still converts differential pressure across a diaphragm into a capacitance or piezoresistive signal, which is then linearized and processed digitally. The PROFIBUS PA interface transmits the primary value cyclically, together with status and diagnostic information, over the same two-wire segment that supplies power to the device.
The local operation concept includes pushbuttons for on-site adjustment, and the digital display (when ordered) can show the measured value and diagnostic codes. Zero-point correction and simulation functions support commissioning and loop verification without a separate calibrator.
Hot-selling Products
7MF4034-1BA00-1AB1
7MF4034-1BA00-1AB6
7MF4034-1BA00-1AB7
7MF4034-1BA00-1AC1
7MF4034-1BA00-1AC6
7MF4034-1BA00-1AF6
7MF4034-1BA00-1BB7
7MF4034-1BA00-1BC1
7MF4034-1BA00-1BC6
7MF4034-1BA00-2BB6
7MF4034-1BA00-2BF6
7MF4034-1BA00-2DB6
7MF4034-1BA10-1AC1
7MF4034-1BA10-1AF6
7MF4034-1BY00-1AB1
7MF4034-1BY00-2AF6
7MF4034-1CA00-1AB1
7MF4034-1CA00-1AB6
7MF4034-1CA00-1AC1
7MF4034-1CA00-1BB7
7MF4034-1CA00-2BB6
7MF4034-1CA10-1AB1
7MF4034-1CA10-1AC1
7MF4034-1CA10-2AC6
7MF4034-1CA10-2BC6
7MF4034-1DA00-1AB1
7MF4034-1DA00-1AB6
7MF4034-1DA00-1AC6
7MF4034-1DA10-1AB1
7MF4034-1DA10-2AB6
Additional circulating codes such as 7MF4034-1DY00-1AB6, 7MF4034-1DA10-1AC6, and 7MF4034-1DC10-2AB6 also appear in legacy inventories and may be relevant for matching specific process connections or approval suffixes.
Selection and Replacement Considerations
When the installed 7MF4034 needs replacement, three documents should be consulted together: the original Siemens order documentation for the full MLFB, the operating instructions for the specific measuring cell range, and the current successor-product comparison for the SITRANS P320 / P420 family. The PROFIBUS PA interface, measuring span, wetted materials, process connection, and explosion protection must all be matched—not only the 7MF4034 prefix.
For engineers evaluating the transition to the P320 / P420 platform, the primary compatibility question is whether the PROFIBUS PA segment configuration and the mechanical process interface remain interchangeable. Siemens successor documentation addresses these points per MLFB, and the legacy 7MF4034 data in this article serves as the reference baseline for that comparison.