pressure transmitter,temperature Transmitter,flow meter-ST-YK CLD

SIEMENS 7MF4035 Gauge Pressure Transmitter

SIEMENS 7MF4035 Gauge Pressure Transmitter

Model:7MF4035-1DA10-2AB6

Manufacturer: Siemens

Size: 30*25*30cm

Detail Specification: Gauge Pressure Transmitter

Comment:Carton

Shipping Weight:4Kg

Payment:T/T

HS CODE:9026201090

Delivery time: 8 weeks

product details

SIEMENS 7MF4035 Gauge Pressure Transmitter

SIEMENS 7MF4035 Gauge Pressure Transmitter — FOUNDATION Fieldbus Measurement with Control-in-the-Field Capability

The SIEMENS 7MF4035 Gauge Pressure Transmitter is the FOUNDATION Fieldbus (FF) configuration within the SITRANS P DS III FF series, designed for gauge pressure measurement where the control strategy is distributed to the field level rather than centralized in a host controller. The 7MF4035 prefix sits alongside the PROFIBUS PA variant (7MF4035) and the HART counterpart (7MF4033) in the same DS III platform, but its FF interface changes what the transmitter can do inside the loop: it is not only a measurement device but also an active participant in fieldbus control execution.

This reference consolidates the engineering data needed to evaluate, specify, or replace the 7MF4035 in FF-based process installations. It is organized around the parameters that matter at the specification stage—measuring range, accuracy, FF function block behavior, wetted materials, hazardous-area approvals, and the successor-product landscape—rather than repeating general product-family descriptions.

Where the 7MF4035 Sits in the DS III FF Architecture

Siemens assigns the 7MF4035 prefix specifically to the gauge pressure transmitter with FOUNDATION Fieldbus output in the DS III FF generation. The same FF platform includes absolute pressure (7MF4235), differential pressure (7MF4335), differential pressure and flow (7MF4435/7MF4535), and level (7MF4635) variants, sharing the piezoresistive measuring cell principle and the same housing and process-connection families.

The distinction between 7MF4035 and 7MF4035 is a communication decision, not a sensing-cell decision. Both use the same gauge pressure measuring cells and the same wetted-parts options. The FF variant transmits a digital Foundation Fieldbus signal over an IEC 61158-2 physical layer, and the device is polarity-independent on the bus segment. That last detail matters during commissioning: a reversed segment polarity will not prevent the device from communicating, which simplifies troubleshooting on live FF segments.

Siemens documentation records the DS III / P410 generation as canceled, with the SITRANS P320 / P420 series designated as the successor direction. For installed 7MF4035 units, this does not change the measurement principle or the FF integration behavior, but it does mean that replacement decisions should involve an MLFB-level comparison against the successor platform rather than a prefix-level substitution.

What FOUNDATION Fieldbus Changes in the Control Loop

The FF interface on the 7MF4035 provides three Analog Input (AI) function blocks and one PID function block within the device itself. This function block set is the practical difference between an FF transmitter and a 4–20 mA device with a digital overlay. The AI blocks can be configured for linearly rising or falling characteristics and support upper/lower warning limits plus alarm limits, allowing the transmitter to flag abnormal process conditions before the value reaches a host alarm threshold.

The embedded PID block means that a control loop can execute at the field device level, reducing the dependency on a central controller for simple regulatory loops. On an FF segment, this translates into faster loop response for local control tasks and continued control execution if the host or supervisory system is temporarily unavailable. For projects migrating from centralized control to field-level automation, the 7MF4035 provides this capability without changing the pressure-sensing hardware.

The device also supports electrical damping adjustable from 0 to 100 seconds, simulation functions, and limit monitoring—features that support loop checking and commissioning without external signal injection equipment.

Key Technical Specifications

The values below reflect the 7MF4035 gauge pressure platform across its standard configurations. Final limits depend on the complete order code, particularly the nominal measuring range, measuring cell filling, process connection, and explosion protection suffix.

ParameterSpecification
Measurement taskGauge pressure (relative pressure)
Communication protocolFOUNDATION Fieldbus, digital signal
Physical layerIEC 61158-2, polarity-independent
Measuring principlePiezoresistive
Accuracy (linear characteristic)≤ 0.075 % of span
Nominal measuring range1 bar g to 400 bar g (14.5 to 5802 psi g)
Standard range steps250 mbar, 1 bar, 4 bar, 16 bar, 63 bar, 160 bar, 400 bar (700 bar on request for certain configurations)
Lower measuring limit (silicone oil fill)30 mbar absolute
Overload / nominal pressurePN 32 (464 psi), PN 160 (2320 psi), or PN 420 (6082 psi), depending on process connection and range
Measuring cell fillingSilicone oil (standard) or inert liquid (grease-free, code 3); Neobee oil available for FDA-compliant fill
Wetted diaphragm materialStainless steel, Hastelloy, or Tantalum, depending on the process connection option
Process connectionG½A female, ½–14 NPT female, oval flange stainless steel, mounting threads 1/16–20 UNF / M10 / M12, male M20 × 1.5, male ½–14 NPT
Housing materialDie-cast aluminium or stainless steel precision casting
Electrical connectionScrewed gland M20 × 1.5, screwed gland ½–14 NPT, or M12 plug (metal)
Display and local operation3 input keys for local programming; optional digital display (visible or concealed)
Diagnostic and simulation functionsElectrical damping 0–100 s, simulation, limit monitoring, sensor-limit monitoring
Function blocks3 × Analog Input, 1 × PID
Hazardous-area approvalsATEX Ex ia, Ex d, Ex ia + Ex d, Ex nA/ic (Zone 2), dust Zone 1D/2D; FM + CSA is / is + xp

Selection Boundaries: Range, Connection, and Approval Codes

The 7MF4035 order code is assembled from independent selection fields rather than a fixed catalog list. The nominal range field separates the standard steps: 250 mbar (A), 1 bar (B), 4 bar (C), 16 bar (D), 63 bar (E), 160 bar (F), 400 bar (G), and 700 bar (J) on request. The process connection field determines the wetted diaphragm and process connection material combination—stainless steel/stainless steel (A), Hastelloy/stainless steel (B), or Hastelloy/Hastelloy (C), with diaphragm-seal versions (Y1/Y0) available for remote-seal configurations.

The explosion protection field is equally consequential. The DS III FF series supports ATEX intrinsic safety, explosion-proof enclosure, combined Ex ia + Ex d, Ex nA/ic for Zone 2, and dust protection. One configuration note is specific to the FF variant: the combined “Ex ia + Ex d + Zone 1D/2D” option is not available for DS III FF, which matters when specifying a dust-rated FF device for a Zone 1D/2D application. The FM + CSA options (is or is + xp) remain available for FF configurations.

Hot-Selling Models

7MF4035-1BA00-1AB1

7MF4035-1BA00-1AB6

7MF4035-1BA00-1AB7

7MF4035-1BA00-1AC1

7MF4035-1BA00-1AC6

7MF4035-1BA00-1AF6

7MF4035-1BA00-1BB7

7MF4035-1BA00-1BC1

7MF4035-1BA00-1BC6

7MF4035-1BA00-2BB6

7MF4035-1BA00-2BF6

7MF4035-1BA00-2DB6

7MF4035-1BA10-1AC1

7MF4035-1BA10-1AF6

7MF4035-1BY00-1AB1

7MF4035-1BY00-2AF6

7MF4035-1CA00-1AB1

7MF4035-1CA00-1AB6

7MF4035-1CA00-1AC1

7MF4035-1CA00-1BB7

7MF4035-1CA00-2BB6

7MF4035-1CA10-1AB1

7MF4035-1CA10-1AC1

7MF4035-1CA10-2AC6

7MF4035-1CA10-2BC6

7MF4035-1DA00-1AB1

7MF4035-1DA00-1AB6

7MF4035-1DA00-1AC1

7MF4035-1DA10-1AB1

7MF4035-1DA10-2AB6

Additional circulating PA codes such as 7MF4035-1DY00-1AB6, 7MF4035-1DA10-1AC6, and 7MF4035-1CC00-1BB7 also appear in legacy inventories and may be relevant when the process connection or approval suffix must be matched exactly.

Replacement and Migration Notes

For an installed 7MF4035, the FF-specific compatibility points are the function block configuration, the segment power and physical layer behavior, and the hazardous-area approval suffix. The three-AI / one-PID block set means that the host’s FF configuration should be checked before replacing a device: a spare transmitter with the same pressure range but a different function block revision may require reconfiguration of the control strategy even if the mechanical and electrical interfaces match.

Because the DS III FF series is recorded as canceled with the P320 / P420 successor direction, a migration evaluation should compare the FF function block set, the process connection, and the approval codes at the MLFB level. The 7MF4035 data in this article provides the baseline for that comparison. The measurement range, wetted materials, and IEC 61158-2 physical layer behavior are the stable reference points; the function block implementation and host integration are the variables that require verification against the successor documentation for each specific loop.

 

 

Obtain relevant certificates and quotations for the product

Scroll to Top

Send Us a Message