SIEMENS 7MF4533 Differential Pressure Transmitter
SIEMENS 7MF4533 Differential Pressure Transmitter
Model:7MF4533-1EA00-1AC6-A01
Manufacturer: Siemens
Size: 30*25*30cm
Detail Specification: Differential Pressure Transmitter
Comment:Carton
Shipping Weight:8Kg
Payment:T/T
HS CODE:9026201090
Delivery time: 8 weeks
product details
SIEMENS 7MF4533 Differential Pressure Transmitter
HART communication over 4–20 mA for remote configuration and diagnostics
High turndown for flexible range adjustment
Optional local LCD for field reading and quick commissioning
Multiple wetted materials for corrosive and high-demand processes
Flow and level derivation when paired with orifice plates, pitot tubes, or closed/open tanks
Industrial enclosure and process connections for harsh plant environments
Approval options such as ATEX, IECEx, FM, CSA, and SIL-related configurations, depending on the order code
For system integrators and maintenance teams, the 7MF4533 is often used as a drop-in measurement solution where HART handhelds, DCS input cards, and asset management tools are already available.
Typical Technical Specifications
| Parameter | Typical specification |
|---|---|
| Product family | SITRANS P DS III differential pressure transmitter |
| Model series | 7MF4533 |
| Measurement type | Differential pressure; flow and level derived with primary elements |
| Output signal | 4–20 mA with HART digital overlay |
| Communication | HART; revision and DD/EDD compatibility depend on electronics option |
| Supply voltage | Typically 10.5–45 V DC; Ex ia versions typically 10.5–30 V DC |
| HART load resistance | Minimum 230 Ω for HART communication; max load depends on supply voltage |
| Accuracy | Typically ±0.075% of span under reference conditions |
| Turndown | Up to 100:1, model-dependent |
| Measuring span | Typically from 0–1 mbar up to 0–500 mbar, depending on configuration |
| Static pressure | Up to 160 bar, model-dependent |
| Overload capability | Within specified static pressure limits |
| Process temperature | Typically -40 to +120 °C with standard fill; remote seals extend range |
| Ambient temperature | Typically -40 to +85 °C |
| Storage temperature | Typically -50 to +85 °C |
| Wetted parts | 316L stainless steel; Hastelloy C-276, Monel, tantalum, and gold-coated diaphragm options |
| Fill fluid | Silicone oil or inert fill, depending on order code |
| Enclosure protection | IP66/IP67; NEMA 4X depending on housing |
| Display | Optional LCD indicator |
| Electrical connection | M20×1.5, 1/2 NPT, PG13.5 options |
| Process connection | 1/4-18 NPT, 1/2-14 NPT, flange adapters and remote seal options |
| Damping | Adjustable, typically 0–100 s |
| Diagnostics | Self-test, loop test, sensor trim, zero/span adjustment via HART |
| Mounting | Direct pipe mounting or bracket/wall mounting |
| Approvals | ATEX, IECEx, FM, CSA, SIL capability depending on configuration |
| Approximate weight | Around 3.5 kg, depending on housing and options |
Note: The values above are typical reference data. Always confirm the final datasheet against the exact order code and nameplate.
HART Communication and Commissioning
The HART protocol allows technicians to read process variables, adjust range, perform sensor trim, and run loop diagnostics without breaking the 4–20 mA loop. In point-to-point mode, the transmitter sends the primary differential pressure value as the analog current while HART digital data is superimposed. In multidrop mode, current output is typically fixed and each device is addressed digitally.
For commissioning, prepare the following:
24 V DC loop supply or compatible DCS card
HART handheld or PC modem with the correct DD/EDD
Minimum loop resistance for HART communication
Nameplate order code and configured measuring range
Static pressure and process temperature limits
Zero trim only after equalizing the DP manifold
Common Applications
Orifice plate flow measurement in water, steam, gas, and chemical lines
Filter and strainer monitoring by measuring pressure drop
Closed and open tank level using hydrostatic differential pressure
Pump differential pressure monitoring
HVAC and building automation differential pressure control
Water and wastewater flow and level measurement
Power plants feedwater, condensate, and steam flow loops
Chemical and petrochemical process lines with compatible wetted materials
30 Popular 7MF4533 Model Codes for Inquiry Reference
The following codes are representative 7MF4533 configurations frequently requested for quotation and cross-reference. They are intended as inquiry references only; final configuration must be confirmed by nameplate, measuring range, diaphragm material, process connection, approval, and electronics option.
| # | Model code | Typical inquiry note |
|---|---|---|
| 1 | 7MF4533-1FA00-1AA6 | Standard HART DP configuration, 316L wetted parts |
| 2 | 7MF4533-1FA00-1AB6 | HART DP with alternate electrical connection |
| 3 | 7MF4533-1FA00-1BA6 | HART DP, industrial housing option |
| 4 | 7MF4533-1FA00-1BB6 | HART DP, LCD and bracket selection reference |
| 5 | 7MF4533-1FA00-1CA6 | HART DP for flow/level inquiry |
| 6 | 7MF4533-1FA00-1CB6 | HART DP with NPT process connection reference |
| 7 | 7MF4533-1FA00-1DA6 | HART DP, standard process temperature |
| 8 | 7MF4533-1FA00-1DB6 | HART DP, alternate housing/electrical option |
| 9 | 7MF4533-1FA00-1EA6 | HART DP for general process monitoring |
| 10 | 7MF4533-1FA00-1EB6 | HART DP with optional display reference |
| 11 | 7MF4533-1FA00-1FA6 | HART DP, 4–20 mA loop configuration |
| 12 | 7MF4533-1FA00-1FB6 | HART DP, M20 electrical entry reference |
| 13 | 7MF4533-1FA00-1GA6 | HART DP for filter differential pressure |
| 14 | 7MF4533-1FA00-1GB6 | HART DP, stainless steel wetted parts |
| 15 | 7MF4533-1FA00-1HA6 | HART DP for tank level inquiry |
| 16 | 7MF4533-1FA00-1HB6 | HART DP, bracket mounting reference |
| 17 | 7MF4533-1FA00-1JA6 | HART DP for utility flow lines |
| 18 | 7MF4533-1FA00-1JB6 | HART DP, alternate process connection |
| 19 | 7MF4533-1FA00-1KA6 | HART DP for water/wastewater applications |
| 20 | 7MF4533-1FA00-1KB6 | HART DP, standard ambient temperature |
| 21 | 7MF4533-1FA00-1LA6 | HART DP for HVAC differential pressure |
| 22 | 7MF4533-1FA00-1LB6 | HART DP, optional LCD reference |
| 23 | 7MF4533-1FA00-1MA6 | HART DP for chemical process inquiry |
| 24 | 7MF4533-1FA00-1MB6 | HART DP, 1/2 NPT reference |
| 25 | 7MF4533-1FA00-1NA6 | HART DP for power plant auxiliary lines |
| 26 | 7MF4533-1FA00-1NB6 | HART DP, alternate fill/ diaphragm inquiry |
| 27 | 7MF4533-1FA00-1PA6 | HART DP for closed tank level |
| 28 | 7MF4533-1FA00-1PB6 | HART DP, approval option inquiry |
| 29 | 7MF4533-1FA00-1QA6 | HART DP for general industrial replacement |
| 30 | 7MF4533-1FA00-1QB6 | HART DP, final configuration to be confirmed |