pressure transmitter,temperature Transmitter,flow meter-ST-YK CLD

SIEMENS 7MF4533 Differential Pressure Transmitter

SIEMENS 7MF4533 Differential Pressure Transmitter

Model:7MF4533-1EA00-1AC6-A01

Manufacturer: Siemens

Size: 30*25*30cm

Detail Specification: Differential Pressure Transmitter

Comment:Carton

Shipping Weight:8Kg

Payment:T/T

HS CODE:9026201090

Delivery time: 8 weeks

product details

SIEMENS 7MF4533 Differential Pressure Transmitter

  • HART communication over 4–20 mA for remote configuration and diagnostics

  • High turndown for flexible range adjustment

  • Optional local LCD for field reading and quick commissioning

  • Multiple wetted materials for corrosive and high-demand processes

  • Flow and level derivation when paired with orifice plates, pitot tubes, or closed/open tanks

  • Industrial enclosure and process connections for harsh plant environments

  • Approval options such as ATEX, IECEx, FM, CSA, and SIL-related configurations, depending on the order code

For system integrators and maintenance teams, the 7MF4533 is often used as a drop-in measurement solution where HART handhelds, DCS input cards, and asset management tools are already available.


Typical Technical Specifications

ParameterTypical specification
Product familySITRANS P DS III differential pressure transmitter
Model series7MF4533
Measurement typeDifferential pressure; flow and level derived with primary elements
Output signal4–20 mA with HART digital overlay
CommunicationHART; revision and DD/EDD compatibility depend on electronics option
Supply voltageTypically 10.5–45 V DC; Ex ia versions typically 10.5–30 V DC
HART load resistanceMinimum 230 Ω for HART communication; max load depends on supply voltage
AccuracyTypically ±0.075% of span under reference conditions
TurndownUp to 100:1, model-dependent
Measuring spanTypically from 0–1 mbar up to 0–500 mbar, depending on configuration
Static pressureUp to 160 bar, model-dependent
Overload capabilityWithin specified static pressure limits
Process temperatureTypically -40 to +120 °C with standard fill; remote seals extend range
Ambient temperatureTypically -40 to +85 °C
Storage temperatureTypically -50 to +85 °C
Wetted parts316L stainless steel; Hastelloy C-276, Monel, tantalum, and gold-coated diaphragm options
Fill fluidSilicone oil or inert fill, depending on order code
Enclosure protectionIP66/IP67; NEMA 4X depending on housing
DisplayOptional LCD indicator
Electrical connectionM20×1.5, 1/2 NPT, PG13.5 options
Process connection1/4-18 NPT, 1/2-14 NPT, flange adapters and remote seal options
DampingAdjustable, typically 0–100 s
DiagnosticsSelf-test, loop test, sensor trim, zero/span adjustment via HART
MountingDirect pipe mounting or bracket/wall mounting
ApprovalsATEX, IECEx, FM, CSA, SIL capability depending on configuration
Approximate weightAround 3.5 kg, depending on housing and options

Note: The values above are typical reference data. Always confirm the final datasheet against the exact order code and nameplate.


HART Communication and Commissioning

The HART protocol allows technicians to read process variables, adjust range, perform sensor trim, and run loop diagnostics without breaking the 4–20 mA loop. In point-to-point mode, the transmitter sends the primary differential pressure value as the analog current while HART digital data is superimposed. In multidrop mode, current output is typically fixed and each device is addressed digitally.

For commissioning, prepare the following:

  • 24 V DC loop supply or compatible DCS card

  • HART handheld or PC modem with the correct DD/EDD

  • Minimum loop resistance for HART communication

  • Nameplate order code and configured measuring range

  • Static pressure and process temperature limits

  • Zero trim only after equalizing the DP manifold


Common Applications

  • Orifice plate flow measurement in water, steam, gas, and chemical lines

  • Filter and strainer monitoring by measuring pressure drop

  • Closed and open tank level using hydrostatic differential pressure

  • Pump differential pressure monitoring

  • HVAC and building automation differential pressure control

  • Water and wastewater flow and level measurement

  • Power plants feedwater, condensate, and steam flow loops

  • Chemical and petrochemical process lines with compatible wetted materials


30 Popular 7MF4533 Model Codes for Inquiry Reference

The following codes are representative 7MF4533 configurations frequently requested for quotation and cross-reference. They are intended as inquiry references only; final configuration must be confirmed by nameplate, measuring range, diaphragm material, process connection, approval, and electronics option.

#Model codeTypical inquiry note
17MF4533-1FA00-1AA6Standard HART DP configuration, 316L wetted parts
27MF4533-1FA00-1AB6HART DP with alternate electrical connection
37MF4533-1FA00-1BA6HART DP, industrial housing option
47MF4533-1FA00-1BB6HART DP, LCD and bracket selection reference
57MF4533-1FA00-1CA6HART DP for flow/level inquiry
67MF4533-1FA00-1CB6HART DP with NPT process connection reference
77MF4533-1FA00-1DA6HART DP, standard process temperature
87MF4533-1FA00-1DB6HART DP, alternate housing/electrical option
97MF4533-1FA00-1EA6HART DP for general process monitoring
107MF4533-1FA00-1EB6HART DP with optional display reference
117MF4533-1FA00-1FA6HART DP, 4–20 mA loop configuration
127MF4533-1FA00-1FB6HART DP, M20 electrical entry reference
137MF4533-1FA00-1GA6HART DP for filter differential pressure
147MF4533-1FA00-1GB6HART DP, stainless steel wetted parts
157MF4533-1FA00-1HA6HART DP for tank level inquiry
167MF4533-1FA00-1HB6HART DP, bracket mounting reference
177MF4533-1FA00-1JA6HART DP for utility flow lines
187MF4533-1FA00-1JB6HART DP, alternate process connection
197MF4533-1FA00-1KA6HART DP for water/wastewater applications
207MF4533-1FA00-1KB6HART DP, standard ambient temperature
217MF4533-1FA00-1LA6HART DP for HVAC differential pressure
227MF4533-1FA00-1LB6HART DP, optional LCD reference
237MF4533-1FA00-1MA6HART DP for chemical process inquiry
247MF4533-1FA00-1MB6HART DP, 1/2 NPT reference
257MF4533-1FA00-1NA6HART DP for power plant auxiliary lines
267MF4533-1FA00-1NB6HART DP, alternate fill/ diaphragm inquiry
277MF4533-1FA00-1PA6HART DP for closed tank level
287MF4533-1FA00-1PB6HART DP, approval option inquiry
297MF4533-1FA00-1QA6HART DP for general industrial replacement
307MF4533-1FA00-1QB6HART DP, final configuration to be confirmed

Obtain relevant certificates and quotations for the product

Scroll to Top

Send Us a Message