pressure transmitter,temperature Transmitter,flow meter-ST-YK CLD

SIEMENS 7MF4534 Differential Pressure Transmitter

SIEMENS 7MF4534 Differential Pressure Transmitter

Model:7MF4534-1EA00-1AC6-A01

Manufacturer: Siemens

Size: 30*25*30cm

Detail Specification: Differential Pressure Transmitter

Comment:Carton

Shipping Weight:8Kg

Payment:T/T

HS CODE:9026201090

Delivery time: 8 weeks

 

product details

SIEMENS 7MF4534 Differential Pressure Transmitter

This guide summarizes typical technical data, selection points, integration details, applications, and 30 commonly requested 7MF4534 ordering-code examples for buyers, integrators, and maintenance teams.

Note: The specifications below are typical and configuration-dependent. Final data must be confirmed against the current Siemens catalog, nameplate, and certificate for the exact ordering code.

Why the SIEMENS 7MF4534 Differential Pressure Transmitter Suits PA Networks

The 7MF4534 is built around a robust differential-pressure sensor and a PROFIBUS PA interface. It is suitable for brownfield upgrades and new PA segments where field devices need to provide more than a single analog value. The transmitter can expose the primary value plus additional process and status information, reducing wiring complexity and improving loop visibility.

Typical integration features include:

  • PROFIBUS PA physical layer according to IEC 61158-2, MBP, 31.25 kbit/s
  • PA Profile 3.0 communication
  • Bus-powered two-wire operation
  • Cyclic process values and acyclic parameter access
  • GSD file, EDD, and DTM support for engineering tools
  • Local zero and span adjustment with optional LCD and keys
  • Self-diagnostics and simulation functions
  • Suitable for use with segment couplers and PA segment protectors

Technical Specifications

ParameterTypical data
Product familySITRANS P DS III differential pressure transmitter
CommunicationPROFIBUS PA, IEC 61158-2, MBP, 31.25 kbit/s
PA profileProfile 3.0
Power supplyBus-powered, 9–32 V DC; Ex limits per certificate
Bus currentApproximately 10–30 mA
Measuring spanFrom 1 mbar up to 30 bar, depending on sensor variant
Turn-downUp to 100:1
AccuracyUp to ±0.075% of span, depending on range and configuration
Long-term stability≤0.1% of span per year, typical
Static pressureHigh-static variants available; final rating per model
Process temperature-40 to +100 °C with silicone oil; remote seals and fill fluids affect limits
Ambient temperature-40 to +85 °C
Storage temperature-50 to +85 °C
Wetted materials316L stainless steel, Hastelloy C-276, tantalum, Monel
Diaphragm material316L stainless steel, Hastelloy, tantalum
Fill fluidSilicone oil or inert fill fluid
Process connection1/4-18 NPT, G1/2, flange adapters and remote seals
Electrical connectionM20x1.5, 1/2 NPT
EnclosureAluminum or stainless steel
Protection classIP66/IP67
DisplayOptional LCD with local operating keys
AdjustmentLocal keys, PROFIBUS PA, SIMATIC PDM or DTM tools
DiagnosticsSelf-test, simulation, status bits, sensor monitoring
ApprovalsATEX, IECEx, FM, CSA, EAC and other regional certificates
SafetySIL-capable variants available
WeightApproximately 3.5 kg, depending on housing and options

Measurement Configuration and Materials

The 7MF4534 can be configured for different process conditions. The main selection variables are:

  1. Measuring span — low spans for filter monitoring and draft pressure; higher spans for process differential pressure.
  2. Static pressure — the transmitter must tolerate the line pressure applied to both sides of the diaphragm.
  3. Diaphragm and wetted materials — 316L stainless steel for general service; Hastelloy C-276, tantalum, or Monel for corrosive media.
  4. Fill fluid — silicone oil for standard applications; inert fill fluid where contamination or oxygen service requires it.
  5. Process connection — NPT, G thread, flange adapters, or remote seals.
  6. Approval and housing — hazardous-area certification, stainless steel housing, and display options.

For flow measurement, the transmitter is typically paired with an orifice plate, averaging pitot tube, or Venturi element. For level measurement in closed tanks, it measures the differential between tank pressure and static head. For filter monitoring, it tracks pressure drop across the filter element.

PROFIBUS PA Integration Notes

The 7MF4534 uses the PA physical layer and is commissioned as part of a PA segment. A typical segment includes a segment coupler or link, a power supply, terminators, and field devices. The engineering tool loads the GSD file so the PLC or DCS can read cyclic values. Parameterization, zero adjustment, and diagnostics can be performed through the bus or local display.

Key integration checks:

  • Confirm the bus address assignment method and available address range.
  • Verify segment power budget and current consumption.
  • Use the correct GSD file and device revision.
  • Confirm Ex barriers or FISCO/Entity parameters for hazardous areas.
  • Check the engineering tool support for EDD and DTM.
  • Keep PA trunk and spur lengths within physical-layer limits.
  • Use terminators at both ends of the PA segment.

Typical Applications

  • Differential pressure flow measurement with primary elements
  • Level measurement in closed and pressurized tanks
  • Filter and strainer differential pressure monitoring
  • Pump and compressor monitoring
  • Leak detection and pressure-drop monitoring
  • Flow verification in utility and process loops
  • Remote-seal level applications in tanks and vessels

Popular 7MF4534 Ordering-Code Examples

The table below lists 30 commonly requested 7MF4534 ordering-code examples. The suffix defines diaphragm material, fill fluid, process connection, approval, housing, display, and other options. Always confirm the exact code for the required configuration before ordering.

#Ordering-code example
17MF4534-1EA00-1AA1
27MF4534-1EA00-1AA2
37MF4534-1EA00-1AB1
47MF4534-1EA00-1AB2
57MF4534-1EA00-1BA1
67MF4534-1EA00-1BA2
77MF4534-1EA00-1BB1
87MF4534-1EA00-1BB2
97MF4534-1FA00-1AA1
107MF4534-1FA00-1AA2
117MF4534-1FA00-1AB1
127MF4534-1FA00-1AB2
137MF4534-1FA00-1BA1
147MF4534-1FA00-1BA2
157MF4534-1FA00-1BB1
167MF4534-1FA00-1BB2
177MF4534-1GA00-1AA1
187MF4534-1GA00-1AA2
197MF4534-1GA00-1AB1
207MF4534-1GA00-1AB2
217MF4534-1GA00-1BA1
227MF4534-1GA00-1BA2
237MF4534-1GA00-1BB1
247MF4534-1GA00-1BB2
257MF4534-1HA00-1AA1
267MF4534-1HA00-1AA2
277MF4534-1HA00-1AB1
287MF4534-1HA00-1AB2
297MF4534-1HA00-1BA1
307MF4534-1HA00-1BA2

 

 

Obtain relevant certificates and quotations for the product