SIEMENS 7MF4634 Level Transmitter
SIEMENS 7MF4634 Level Transmitter
| Model:7MF4634-1DY01-1AA1-Z Manufacturer: Siemens Size: 30*25*30cm Detail Specification: pressure transmitter Comment:Carton Shipping Weight:4Kg Payment:T/T HS CODE:9026201090 Delivery time: 8 weeks
|
product details
SIEMENS 7MF4634 Level Transmitter
The SIEMENS 7MF4634 Level Transmitter is a differential-pressure transmitter from the SITRANS P DS III family, commonly selected for level, interface, and flow measurement in process tanks, columns, boilers, and separators. It combines stable sensor performance, 4–20 mA HART communication, and remote-seal options for demanding liquid-level applications.
Key Technical Parameters
| Parameter | Typical 7MF4634 Data |
| Product family | SITRANS P DS III differential pressure |
| Primary application | Level, interface, differential pressure, flow |
| Output signal | 4–20 mA with HART |
| Accuracy | Up to ±0.075% of span |
| Power supply | 10.5–45 V DC |
| Measuring span | Variant-dependent, from low mbar to high static pressure ranges |
| Process temperature | −40 to 85 °C, depending on fill fluid and remote seal |
| Ambient temperature | −40 to 85 °C |
| Protection class | IP66/IP67 |
| Wetted materials | Stainless steel, Hastelloy, Monel options |
| Process connections | DN50/DN80, ANSI 2 in/3 in, flange and remote-seal options |
| Fill fluids | Silicone oil, inert oil, high-temperature oil |
| Capillary length | Up to 10 m, configuration-dependent |
| Approvals | ATEX, IECEx, CE, SIL2/SIL3 options |
| Communication | HART; optional foundation fieldbus/profibus versions in related families |
These parameters make the 7MF4634 suitable for closed-tank level measurement, density and interface detection, and differential-pressure flow monitoring. Remote seals help protect the transmitter from corrosive, viscous, or high-temperature media.
Level Measurement Applications
- Closed and pressurized storage tanks
- Distillation and process columns
- Boiler drum and separator level
- Chemical reactors and mixing vessels
- Interface measurement between two liquids
- Filter and pipeline differential-pressure monitoring
Top 30 Popular 7MF4634 Configurations
The following model codes are commonly requested examples for level applications. Final codes should be confirmed against the datasheet and option codes.
- 7MF4634-1DY01-1AA1-Z
- 7MF4634-1DY01-1AB1-Z
- 7MF4634-1DY01-1AC1-Z
- 7MF4634-1DY01-1BA1-Z
- 7MF4634-1DY01-1BB1-Z
- 7MF4634-1DY01-1CA1-Z
- 7MF4634-1DY01-1CB1-Z
- 7MF4634-1DY01-1DA1-Z
- 7MF4634-1DY01-1DB1-Z
- 7MF4634-1DY01-1EA1-Z
- 7MF4634-1DY01-1EB1-Z
- 7MF4634-1DY01-1FA1-Z
- 7MF4634-1DY01-1FB1-Z
- 7MF4634-1DY01-1GA1-Z
- 7MF4634-1DY01-1GB1-Z
- 7MF4634-1DY01-1HA1-Z
- 7MF4634-1DY01-1HB1-Z
- 7MF4634-1DY01-1JA1-Z
- 7MF4634-1DY01-1JB1-Z
- 7MF4634-1DY01-1KA1-Z
- 7MF4634-1DY01-1KB1-Z
- 7MF4634-1DY01-1LA1-Z
- 7MF4634-1DY01-1LB1-Z
- 7MF4634-1DY01-1MA1-Z
- 7MF4634-1DY01-1MB1-Z
- 7MF4634-1DY01-1NA1-Z
- 7MF4634-1DY01-1NB1-Z
- 7MF4634-1DY01-1PA1-Z
- 7MF4634-1DY01-1PB1-Z
- 7MF4634-1DY01-1QA1-Z












