pressure transmitter,temperature Transmitter,flow meter-ST-YK CLD

YOKOGAWA VJU7-027-UAA0

Model:YOKOGAWA VJU7-027-UAA0

Manufacturer: YOKOGAWA

Size: 20*20*30cm

Detail Specification: temperature converter

Comment:Carton

Shipping Weight:1Kg

Estimated Lead Time: 12 Weeks

Payment:T/T

HS CODE:9026201090

Unit price (EXW): 590 US dollars

Delivery time: 12 – 16 weeks

product details

YOKOGAWA VJU7-027-UAA0

Product Overview

The YOKOGAWA VJU7-027-UAA0 is a precision universal temperature converter from the JUXTA VJ Series, manufactured by Yokogawa Electric Corporation. This plug-in type signal conditioner converts thermocouple, RTD, or millivolt (mV) input signals into isolated DC voltage or current output signals, providing reliable and accurate temperature measurement for industrial automation systems. Based on a microprocessor-driven design, the VJU7 series integrates seamlessly with DCS, PLC, and SCADA architectures, serving process industries such as chemical, petrochemical, power generation, and HVAC applications-11.

Model Number Breakdown: YOKOGAWA VJU7-027-UAA0

The suffix code provides a complete product identification:

Code SegmentInterpretation
VJU7Universal temperature converter (thermocouple, RTD, mV input)-21
-0Fixed designation code
2Output configuration: Isolated dual-output type-12
7Power supply: 15–30 V DC (operating range: 12–36 V DC)-16
Separator
UInput signal: Universal (thermocouple / RTD / mV)-12
AOutput-1 signal: 4–20 mA DC
AOutput-2 signal: 4–20 mA DC-12
0Fixed code (always 0)

The VJU7-027-UAA0 therefore represents a dual-output, 15–30 V DC powered universal temperature converter configured with 4–20 mA DC linear output on both channels.

Key Specifications

General Specifications

ParameterSpecification
TypeUniversal temperature converter (multifunction)-16
MountingPlug-in type (with socket), wall, DIN rail, or VJCE base mount-11
Dimensions (H × W × D)76 × 29.5 × 124.5 mm-11
Connection methodM3 screw terminal
WeightApprox. 200 g (including socket)
WarrantyThree years-11

Input Specifications

ParameterSpecification
Input typeThermocouple: K, E, J, T, B, R, S, N, L, U; RTD: Pt100, JPt100, Ni508; DC mV: –10 to +100 mV-16
Input resistance≥ 1 MΩ (for mV input)
Burnout detectionUpscale burnout standard; downscale available
Reference junction compensation (RJC)Automatic with internal sensor (RJC sensor included)
RJC accuracy±0.5°C

Output Specifications

ParameterSpecification
Output-1 signal4–20 mA DC (linear)-12
Output-2 signal4–20 mA DC (linear)-12
Maximum load resistance600 Ω (for 4–20 mA output)
Output response time≤ 0.5 s (0→90%)
Ripple≤ 0.5% p-p

Accuracy and Performance

ParameterSpecification
Reference accuracy (mV input)±0.05% of span
Reference accuracy (thermocouple)±0.05% of span ±0.5°C (RJC included)
Reference accuracy (RTD)±0.05% of span ±0.3°C
Ambient temperature effect±0.01%/°C of span
Warm-up time10–15 minutes to meet performance-16
Isolation withstand voltage2000 V AC (input–output–power–ground)-11
Insulation resistance≥ 100 MΩ at 500 V DC

Power Supply Specifications

ParameterSpecification
Supply voltage range15–30 V DC (±20%)
Operating range12–36 V DC-16
Power consumption≤ 3 VA
Current consumption (at 24 V DC)≤ 80 mA (dual-output)

Environmental and Safety Specifications

ParameterSpecification
Operating temperature–5°C to +55°C
Storage temperature–25°C to +70°C-16
Operating humidity5–95% RH (non-condensing)
Altitude≤ 2000 m
Conformity standardsCE, UL, CSA, KC, RCM-16
EMC standardsEN 61326-1 Class A, Table 2; EN 55011 Class A Group 1-16
RoHS DirectiveEN 50581-16

Obtain relevant certificates and quotations for the product

Scroll to Top

Send Us a Message