YOKOGAWA ZA8F-01-A

Model:YOKOGAWA ZA8F-01-A

Manufacturer: YOKOGAWA

Size: 约 140×120×80 mm

Detail Specification: Manual calibration using ambient air for reference

Comment:Carton

Shipping Weight:2.3Kg

Estimated Lead Time: 12 Weeks

Payment:T/T

HS CODE:9026201090

Unit price (EXW): 2900US dollars

Delivery time: 12 – 16 weeks

 

product details

YOKOGAWA ZA8F-01-A

The YOKOGAWA ZA8F is a dedicated flow setting unit designed specifically for zirconia oxygen/humidity analyzers, including the EXAxtZR ZR22G/ZR402G system and the ZS8 flameproof oxygen analyzer. This compact unit integrates flowmeter and flow control valves for precise gas flow management during manual calibration procedures. The ZA8F enables one-touch calibration via the converter’s key operation, delivering repeatable measurement conditions across combustion monitoring and control applications-3-31.

Below is a complete technical breakdown, followed by a detailed model analysis of ZA8F-01-A.

Complete Technical Specifications (ZA8F Series)

All data applies to the ZA8F series and the specific configuration ZA8F-01-A.

ParameterSpecification
ManufacturerYokogawa Electric Corporation
Product SeriesZA8F
System CompatibilityZR402G converter; ZR22G detector; ZS8D detector; ZS8C converter; EXAxtZR separate-type zirconia oxygen analyzer; ZS8 flameproof oxygen analyzer
ApplicationManual calibration gas flow control — reference gas and calibration gas (System 1/System 2)
**Flowmeter ScaleCalibration Gas**0.1 to 1.0 L/min
**Flowmeter ScaleReference Gas**0.1 to 1.0 L/min
Calibration Gas ConsumptionApprox. 0.7 L/min (at calibration time only) 
Reference Gas ConsumptionApprox. 1.5 L/min (continuous) 
ConstructionDust-proof and rainproof -11 
Case MaterialSPCC (Cold rolled steel sheet) -11 
Exterior FinishBaked epoxy resin, Dark-green (Munsell 2.0 GY 3.1/0.5 or equivalent) -11 
Pipe ConnectionsRc 1/4 or 1/4 FNPT (Female) 
Reference Gas PressureMeasured gas pressure + 50 kPa G; or +150 kPa G if check valve used (maximum: 300 kPa G) 
WeightApprox. 2.3 kg -11 
Mounting Options2-inch pipe (nominal JIS 50A) or wall-mounted; vertical orientation required 
**Ambient TemperatureOperating**–20 °C to +55 °C
**Ambient HumidityOperating**0 to 95% RH (non-condensing)
Span Calibration Gas (recommended)Instrument air (clean and dry) 
Zero Calibration GasSupplied from external cylinder (user-supplied) 

Reference: Table is based on data compiled from YOKOGAWA IM 11M12A01-02E, IM 11M12A01-04E, and IM 11M7A3-01E-11-3.

System Configurations: Where ZA8F Fits

The ZA8F flow setting unit supports two primary system architectures within YOKOGAWA’s zirconia analyzer ecosystem:

System ConfigurationDescriptionReference GasSpan GasZero Gas
System 1Manual calibration using ambient air for referenceAmbient air (21% O₂) drawn naturallyAmbient air via converter internal pumpCylinder
System 2Manual calibration using instrument air for both reference and spanClean instrument air via ZA8FClean instrument air via ZA8FCylinder with ZA8F

In System 2, the ZA8F manually controls gas flow during calibration. Instrument air (21% O₂, clean and dry) functions as both reference gas and span gas. Zero gas from an external cylinder is supplied through the ZA8F during zero calibration only-2-24.

Model Code Breakdown: ZA8F-01-A

The complete model ZA8F-01-A follows YOKOGAWA’s suffix-based ordering convention. Each segment defines a specific configuration attribute.

Model SegmentCodeDescription
Product SeriesZA8FFlow Setting Unit for zirconia oxygen/humidity analyzers
**Suffix CodeJoint Type**-01Standard gas connection configuration — with 1/4 NPT adapter
Option / Style Code-AStyle code defining standard accessory package, dimensional compliance, and factory configuration of the flow setting unit set 

Physical Configuration & Application

⚙️ Component Layout

The ZA8F incorporates three dedicated flow adjustment valves:

ValveLabelFunction
Right + front needle valveSPANCalibration gas (span / zero) flow setting and flowmeter
Top handwheelZEROZero gas flow setting valve

During normal measurement, all valves are closed. Calibration requires sequentially opening each valve while observing the calibration gas flowmeter scale (set to 0.6 ± 0.06 L/min for span gas and 0.5 ± 0.05 L/min or equivalent for zero gas)-29-32.

 