pressure transmitter,temperature Transmitter,flow meter-ST-YK CLD

YOKOGAWA ZR22G100SKCTTEA

Model:ZR22G100SKCTTEA

Manufacturer: YOKOGAWA

Size: 20*20*30cm

Detail Specification: umidity detector

Comment:Carton

Shipping Weight:10Kg

Estimated Lead Time: 12 Weeks

Payment:T/T

HS CODE:9026201090

Unit price (EXW): 4000US dollars

Delivery time: 12 – 16 weeks

 

product details

YOKOGAWA ZR22G100SKCTTEA

The Yokogawa ZR22G100SKCTTEA is a premium separate-type zirconia oxygen/humidity detector, engineered for real-time monitoring of oxygen concentration in industrial combustion exhaust gases and mixed gas streams. As a core component of Yokogawa’s OpreX Analyzers portfolio, it delivers exceptional accuracy, durability, and compatibility, making it ideal for power boilers, steel heating furnaces, petrochemical process heaters, and waste incinerators Yokogawa Electric Corporation. Paired with compatible converters like ZR402G or ZR802G, it forms a complete system for combustion optimization, enabling energy savings, reduced NOx/SOx emissions, and enhanced operational safety Yokogawa Electric Corporation.

Key Model Code Breakdown: ZR22G100SKCTTEA

 

Code SegmentDefinition
ZR22GSeries: Separate-type zirconia oxygen/humidity detector (general-purpose)
100Probe insertion length: 1.0 meter (100 = 1000mm)
SWetted material: SUS316 stainless steel (corrosion-resistant for harsh flue gases)
KProcess flange: JIS 5K 65FF (Japanese standard, 5K pressure rating, 65mm face, flat face)
CReference gas mode: Natural convection (no external instrument air required, cost-effective)
TGas connection thread: 1/4 NPT female (standard for industrial gas lines)
TJunction box thread: 1/2 NPT female (secure wiring connection)
ECable entry: Standard cable gland (IP44D ingress protection rating)
ABase configuration: Standard specifications (no additional options)

Core Technical Specifications

ParameterDetail
Measurement PrincipleZirconia  (Zirconia concentration cell)
Oxygen Measurement Range0.01–100 vol% O₂ (configurable in 1 vol% increments; partial range available)
Humidity Measurement Range0–100 vol% H₂O (compatible with high-temperature humidity monitoring)
Sample Gas Temperature0–700°C (probe-only; up to 1400°C with ZR22P-H high-temperature adapter)
Sample Gas Pressure-5 to +20 kPa (standard; pressure-compensated variant available for higher pressures)
Output Signal4–20 mA DC (2 channels, max load 550Ω); HART 7 digital communication (multi-drop mode)
Repeatability±0.5% FS (0–5/25 vol% O₂); ±1% FS (25–100 vol% O₂)
Linearity±1% FS (0–5/25 vol% O₂); ±3% FS (25–50 vol% O₂); ±5% FS (50–100 vol% O₂)
Response Time≤5 seconds (90% response)
Warm-Up Time~20 minutes (stable measurement readiness)
Drift±2% FS/month (zero/span, excluding initial 2 weeks)
Wetted MaterialsSUS316 stainless steel, zirconia sensor, SUS304 flange ( Hastelloy B/Inconel options for corrosive gases)
Ambient Temperature-20 to +150°C (probe); -20 to +55°C (converter)
Weight~8 kg (1.0m probe, JIS 5K 65FF flange)
Safety & ComplianceEN 61010-1, EN 61326-1 Class A, RoHS compliant

Complementary ZR22 Series Models

The ZR22G platform offers flexible configurations to suit diverse application needs:

  • ZR22G040SKCTTEA: 0.4m probe length (compact, for shallow furnace insertion)
  • ZR22G070SKCTTEA: 0.7m probe length (medium-depth insertion)
  • ZR22G150SKCTTEA: 1.5m probe length (deep furnace insertion for large boilers)
  • ZR22G200SKCTTEA: 2.0m probe length (industrial heating furnaces)
  • ZR22G250SKCTTEA: 2.5m probe length (heavy-duty industrial applications)
  • ZR22G300SKCTTEA: 3.0m probe length (large-scale incinerators)
  • ZR22S Series: Explosion-proof variants (ATEX/FM certified for hazardous areas)
  • ZR22P Series: High-temperature adapters (for 700–1800°C process gases)

Key Advantages & Applications

Reliable Performance: Long-life zirconia sensor with field-replaceable heater assembly reduces maintenance costs and downtime.

Flexible Configuration: Multiple probe lengths, flange types, and reference gas options (natural convection/instrument air/pressure-compensated) adapt to diverse installation scenarios.

Seamless Integration: HART 7 and Modbus TCP/RTU communication enable remote monitoring, calibration, and data integration with DCS/PLC systems.

Industrial-Grade Durability: Corrosion-resistant materials and IP44D/IP66 ingress protection (with sealed cable gland) withstand harsh industrial environments.

Typical applications include power plant boilers (coal/gas/oil-fired), steel mill reheating furnaces, petrochemical cracking furnaces, cement kilns, and waste-to-energy incinerators. It supports combustion efficiency optimization by maintaining optimal O₂ levels, reducing fuel consumption and greenhouse gas emissions while ensuring compliance with environmental regulationsYokogawa Electric Corporation.

Installation & Maintenance Notes

Mounting: Flange-mounted (JIS 5K 65FF); probe insertion angle: horizontal to vertically downward (≤±5° for lengths ≤2m; vertical for >2.5m).

Calibration: Zero/span calibration (0.3–100 vol% O₂ zero range; 4.5–100 vol% O₂ span range) via manual/semi-automatic mode (ZR20H calibration unit optional).

Accessories: ZR22R probe protector (for particulate-laden flue gases), ZR22V support clamp (for long probes), and fly ash filters (for high-dust environments).

The Yokogawa ZR22G100SKCTTEA delivers industry-leading performance for industrial combustion oxygen monitoring, combining precision, durability, and versatility to meet the demands of modern process industries.

 

Obtain relevant certificates and quotations for the product

Scroll to Top